Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Saia PCD4.U100 Kit System Upgrade Guide

F: | Au:FAN | DA:2026-03-26 | 565 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Saia PCD4.U100 System Upgrade Kit: A Smooth Migration Guide from Classic to Modern

In the field of industrial automation, technological iteration and system upgrading are inevitable requirements for maintaining equipment competitiveness and improving operational efficiency. For users using the Saia PCD4 classic series PLC, upgrading their core control system to the new generation PCD2.M5 or PCD3. M series platforms based on NT-OS is an ideal choice to improve performance and extend the system lifecycle. The PCD4.U100 kit was born for this purpose, serving as a bridge between old and new platforms, allowing users to enjoy higher processing speeds and richer features brought by the new CPU while retaining their existing investment in PCD4 I/O modules. This article aims to provide a comprehensive and professional technical reference for automation engineers by delving into the official technical manual of the PCD4.U100 suite, systematically explaining the key technical points, operational steps, and precautions throughout the entire migration process.


Part 1: Migration Preparation and Compatibility Assessment

A successful system upgrade begins with careful planning and comprehensive compatibility checks.

1.1 Core migration process

At the beginning of the manual, a clear migration checklist is provided, outlining the execution path of the entire project:

Hardware check: First, confirm that all existing PCD4 I/O modules can be used in the new system.

Hardware installation: Replace the original PCD4 CPU with the PCD4. U100 kit and install a new PCD2. M5 or PCD3. M series CPU. The original PCD4 I/O module will continue to be used.

Software preparation: Ensure Saia PG5 ®  Develop software version not less than 1.4.300 (patch 15 must be installed) or 2.0.150 (SP1).

Project conversion: Open the original project in PG5. For projects programmed using Fupla (Function Block Diagram) or IL (Instruction List), the system will automatically or manually update the code.

Download and debug: After completing the program adaptation, download the new program to the new CPU and perform system testing.

1.2 Hardware Compatibility Checklist

Before starting the physical installation, it is necessary to strictly check the compatibility list to avoid hardware damage or system failure caused by incompatibility.

Supported CPUs: CD2.M5xxx (firmware version 1.10.16 or higher) and PCD3.Mxxxx (firmware version 1.10.16 or higher). These new CPUs are all equipped with the NT-OS operating system.

Power module: PCD4. N2x0 power module, and the hardware version needs to be B or updated. The manual specifically warns that using older versions of power modules may damage the PCD4.U100 kit, which requires high attention.

Unsupported modules: All PCD4. HXxx series modules (such as high-speed counting, positioning, and other intelligent modules) are not supported. This means that during the upgrade process, if the original system contains such modules, alternative solutions or redesign of related functions need to be sought.

Software version: As mentioned earlier, the specified version or higher of Saia PG5 must be used ® Develop software to ensure that new I/O libraries and functional blocks can function properly.


Part 2: Hardware Installation and Addressing Mode Configuration

The core of hardware installation lies in the connection of the PCD4.U100 kit and the address allocation of new and old I/O modules.

2.1 Role of PCD4.U100 kit

The PCD4.U100 kit is essentially an adapter that connects the new PCD2/3 CPU to the existing PCD4 I/O rack. It converts the high-speed I/O bus of the new CPU into signals that the old PCD4 system can recognize, while processing power and address mapping. The correct installation of this module is the physical foundation for achieving the integration of old and new platforms.

2.2 Selection and Influence of Addressing Modes

This is one of the most critical technical decisions in the migration process, determining how the new CPU "sees" and manages physical I/O points. A micro switch on the back of the PCD4. U100 module provides four addressing modes, with two main modes being the most commonly used:

Mode 1: Address starts from '0' (no new I/O module)

In this mode, the address space of the PCD4 I/O module starts from 0 and is directly mapped to the I/O bus of the new CPU.

Advantages: The original PCD4 program does not require any address changes and can be used directly.

Cost: Unable to add any new PCD2/3 I/O modules to the idle slots of the new CPU. Because address 0 is already occupied. This also means that no intelligent modules (such as PCD2/3. Fxxx communication modules) or memory modules (such as PCD2/3. R6xx) can be added.

Applicable scenarios: Only perform CPU upgrades, do not expand any new hardware, and strive to minimize program changes.

Mode 2: Address starting from '256' (new I/O modules can be added)

In this mode, the addresses of all PCD4 I/O modules are offset by 256. For example, the module with the original address of 0 has its address changed to 256 in the new system.

Advantages: The 0-255 address range on the new CPU bus is released and can be used to install up to 8 new PCD2/3 I/O modules. This provides the possibility for system expansion.

  • Basler DECS-250-CGCM-LN2SA1C Digital Excitation Control System
  • Valmet Automation PLC Module A413171
  • Valmet Automation 542852-3A Rack-Mount Cross Connect Panel
  • Valmet Marine Damatic M851565 Main Keyboard
  • Valmet TIU 6 Printed Circuit Board A413110
  • Metso Valmet U4440253V1.1 RMI CPU 300
  • Metso Valmet A413016 Ver.12 NCU2
  • Valmet M851565 Damatic Keyboard
  • Valmet ATB16-4 16 Channel Relay Card
  • Valmet Metso A413331 SPU Power Supply
  • Valmet PUD 10B Automation Control Rack
  • Valmet MT917 ABMB DMU PCB I/O Module
  • Valmet M851565 Damatic Keyboard Mkb2
  • Valmet EDS-518A-MM-SC Ethernet Gateway
  • Valmet 542836-6A PCB Card
  • Valmet ATB16-4/2 Terminal Board 9144047
  • Valmet ATB16-4 Controller Board 0-50°C 4-20mA Analog Output
  • Valmet 542852-3A Slot Rack Chassis Module
  • Valmet A413026 Ver.M1 FBC Board
  • Valmet IQ Basis Weight SH Sending Assembly A418081
  • Valmet PMB 2R Monolithic Backplane 8-Slot PCB 542821-5A and -5B
  • Valmet ATB16-4 16-Channel Relay Card Controller Board 22195028
  • Valmet Diff-EL SL6NK227SF0 Pressure Transmitter 0-380 mBar
  • Valmet A413110 TIU6 Board Ver.M1
  • Neles Automation A413278 Control Module
  • Valmet BCUTB Terminal Module 10101006 11091002
  • Valmet Senso 160 Measuring Station Display 160.2
  • Valmet AIU 1A Analog Input Unit M851245
  • Valmet IQ Web Caliper Sensor A420734
  • Valmet M851040/M8510401 Memory Board
  • Valmet AN35S1MC02RA Valve
  • Valmet M851121 M2 Cross Connect Panel
  • Valmet AIU-8 Simulator Board 421522-1A
  • Metso BIU 82 D200533 Binary Input Unit
  • Valmet M851121 M2 Module Rack
  • Valmet A413383 PC Board Module
  • Valmet N0542 NO54 ABMB PCB - 545200-3A Board
  • Valmet Metso IOP304 Input Module 181503
  • Valmet PDP601 Distributed Processing Unit 181585
  • Valmet A413084 CPU Board - Processor Module for Automation Systems
  • Valmet AIU 16T Analog Input Module M8512081 M1
  • Valmet AIU 16 Analog Input Module 545100-3A and 545100-3B
  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module