Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

EATON XV-303/XV-313 series industrial multi touch HMI display

来源: | 作者:FAN | 发布时间 :2026-03-10 | 11 次浏览: | Share:

Located on the side of the device, supporting SDSC and SDHC cards (compliant with SDA 2.0 specifications):

Insertion: Push into the card slot until you hear the sound of the card entering

Remove: Push the card back into the limit position and then pull it out

Attention: The SD card must be plugged in and out while the device is powered off to ensure that no program is writing to it

6.2 USB interface

USB Host(Type A):

Used to connect external devices such as USB drives, mice, keyboards, etc

Output capacity: 500mA (full power)

Only for maintenance work in industrial environments

USB Device(Type B):

Used to connect to the upper computer for data transmission or debugging

Recommend using a shielded USB cable with a maximum length of 5m

6.3 Ethernet interface

Interface type: RJ45, 8-pin, with 2 LED indicator lights

Green LED: lit to indicate link connection (LINK)

Yellow LED: flashing indicates data transmission in progress

Technical specifications:

Support speed: 10/100 Mbit/s, adaptive

Cable requirements: shielded twisted pair (STP) CAT5e/6

Mechanical protection: Avoid strong vibrations and tensile forces

Functional differentiation:

Ethernet 1: Can be used as a communication interface or real-time fieldbus interface

Ethernet 2 (C00 model only): Used only as a communication interface, no real-time requirements

6.4 RS-232 interface (COM1)

9-pin D-Sub plug (male), non electrically isolated:

Pin definitions: DCD (1), RXD (2), TXD (3), DTR (4), GND (5), DSR (6), RTS (7), CTS (8), RI (9)

The relationship between maximum baud rate and line length:

2.5m:115200 bit/s

5m:57600 bit/s

10m:38400 bit/s

15m:19200 bit/s

30m:9600 bit/s

6.5 RS-485 interface (COM2)

9-pin D-Sub plug (male), non electrically isolated:

Pin definitions: DATA+(3), DATA - (7), GND (5)

Attention: Pin 6 (5V) is strictly prohibited from being used as an external device power supply

Bus specification:

Characteristic impedance: 120 Ω

Allowable impedance range: 108-132 Ω

Maximum line length: 1200m

Maximum number of nodes per segment: 32

Both ends must be connected with 120 Ω terminal resistors

6.6 CAN interface

9-pin D-Sub plug (male), compliant with CiA standards:

Pin definitions: CAN-L (2), GND (3), CAN-H (7)

Pin 3 (CAN-GND) is internally connected to Pin 6 (GND)

The power supply for the CAN bus driver is provided internally by the device and cannot supply power to external devices

Bus specification:

Characteristic impedance: 120 Ω

Allowable impedance range: 108-132 Ω

Unit length capacitance:<60 pF/m

The relationship between maximum wire length and wire diameter:

100m:≥0.25mm²

250m:≥0.34mm²

500m:≥0.75mm²

Software and System Integration

7.1 Operating System

The XV300 series uses the Linux operating system, providing users with an open and stable software platform. The system supports multiple programming languages and development environments, making it easy to port and develop applications.

7.2 Visualization software

The device can be optionally authorized with GALILEO visualization software (order number suffix -2B or -2C). GALILEO is Eaton's advanced HMI development tool that supports:

Rich graphic elements and animation effects

Multilingual management

Formula management and data recording

Alarm and historical event handling

Multiple PLC driver protocols

7.3 Embedded PLC Functions

The model with PLC function (suffix -2C) integrates the CoDeSys soft PLC runtime system and supports all five programming languages of IEC 61131-3 (LD, FBD, ST, IL, SFC). This enables XV300 to serve as both HMI and controller, simplifying the system architecture and reducing hardware costs.

7.4 Communication Protocol Support

Through Ethernet and serial interface, XV300 can communicate with various brands of PLCs, supporting protocols including but not limited to:

Modbus TCP/RTU

CANopen

J1939

Various proprietary PLC drivers (to be configured in GALILEO)


Safety precautions and maintenance

8.1 Important safety warnings

Explosion hazard:

The equipment shall not be used to plug or unplug connectors with electricity in hazardous and explosive environments

Improper handling of internal lithium batteries may cause explosions and must be professionally disposed of

Electrostatic discharge:

Before coming into contact with the equipment, it is necessary to release static electricity from the human body

Avoid touching static sensitive components (such as connector pins)

Electromagnetic compatibility:

Professional assembled shielded cables must be used

Signal lines and power lines should be wired separately

All connectors need to be tightened or locked to improve shielding effectiveness

Condensation hazard:

Equipment may experience internal condensation after experiencing environmental fluctuations

It is strictly prohibited to turn on the machine when there is condensation

The equipment should be adapted to the ambient temperature before being put into operation

8.2 Daily Maintenance

Cleaning:

Clean the touch screen with a clean, soft, damp cloth

Prohibit the use of sharp or hard objects

Prohibit the use of corrosive or abrasive cleaning agents

Touch screen calibration:

If the touch response is inaccurate, it can be calibrated through the Linux system

Please refer to the Linux system description document for specific methods

  • UNIOP eTOP20C-0050 Color HMI Touch Panel Data
  • UNIOP MD00R-02-0045 Text-Based Display Module
  • UNIOP eTOP05-0045 Operator Interface
  • UNIOP ETOP11-0050 HMI Color Operator Interface Data
  • UNIOP eTOP306 Industrial Touch Panel
  • UNIOP CP04F-04-0045 HMI Panel
  • UNIOP ETOP308U301 HMI Touch Panel
  • UNIOP MD00R-02-0045 Operator Panel
  • UNIOP ePALM10-0061 Handheld Teach Pendant
  • UNIOP CP05R-04-0045 HMI Operator Panel
  • UNIOP MD02R-04-0045 Text-Based Operator Module
  • UNIOP CP02R-04-0021 Compact Operator Panel
  • UNIOP CP04F-04-1945 Industrial HMI Control Panel
  • UNIOP ECT-16-0045 Communication Module Data Sheet
  • UNIOP EPALM10-0061 Handheld HMI Technical Specifications
  • UNIOP ERT-16-0042 Remote Terminal Unit
  • UNIOP ePAD04-0046 HMI Controller
  • UNIOP BKDR-16 Operator Interface Display
  • UNIOP MKDR-04-004 Control Unit Panel
  • UNIOP ETOP515U3P1 HMI Touch Panel
  • AMAT 0190-15779 Advanced Controller Module
  • Applied Materials AMAT 0010-23715 Mechanical Assembly
  • AMAT 0190-14502 Communication Interface Module
  • AMAT 0195-14157.RMA Power Distribution Module
  • Applied Materials AMAT 0021-84842 Precision Component
  • AMAT 0190-37519 DC Power Supply
  • AMAT 0100-71267 RF Generator Module
  • ALSTOM V4561484-0100 Analog Input Module
  • ALSTOM PIB903 Process Interface Board
  • ALSTOM 029.202.781 Protection Relay
  • ALSTOM 029.148.924 Enhanced Motor Relay
  • ALSTOM 029.148.906 Motor Protection Relay
  • ALSTOM 029.147.908 Transformer Protection Relay
  • ALSTOM 029.144.456 Advanced Feeder Relay
  • ALSTOM 029.144.440 Feeder Protection Relay
  • ALSTOM P40 AGILE MiCOM P141 Feeder Protection Relay
  • ALSTOM I/OBE2 12004-104-00 V1.0.0 I/O Interface Module
  • ALSTOM V4561983-0100 Industrial Control Module
  • ALSTOM VOOB8-B 12004-106-04 V1.0.0 Output Interface Board
  • ALSTOM VPS 12004-102-03 V1.0.0 Voltage Processing Board
  • ALSTOM POS1846 TRVC062333000 CP00000310 Position Control Module
  • ALSTOM DSI1817 TRVC062335000 CP00003934 Digital Input Module
  • ALSTOM CMP1838 TRVCO62345000 CP00005202 Processor Module
  • ALSTOM STO1726KO1 Integrated Control Module
  • ALSTOM I/OBUS2 12004-103-01 VER:V1.2.0 Communication Interface
  • ALSTOM 730475-D ELEMENTS-F2 Cabinet Heater
  • ALSTOM N897163510Q / N897163050Q MODEM and N897163100U Interface Unit
  • ALSTOM N897066 AOVD Analog Output Module
  • ALSTOM CMU 42015-115-00 Communication Unit
  • ALSTOM NRD108028 Digital Protection Relay
  • ALSTOM 42011-106-00 ITC_VIOM_VIOC VER.A01 Interface Card
  • ALSTOM N897093511D DIAGNOSTICA N897093400H Interface Unit
  • ALSTOM N895609510K N895609010R E32OUT Digital Output Module
  • ALSTOM MLU VER.A01 Main Logic Unit
  • ALSTOM NRD109475 8RDA44670G01 SA44670.E Control Module
  • ALSTOM VIIB16-C 12011-105-00 Interface Board Module
  • ALSTOM VCS232 590.043158 Control System Module
  • ALSTOM V0701596-001102 Industrial Control Module
  • ALSTOM N895313512X N95313012D SUP-AL Control Module
  • ALSTOM 12004-102-01 VPS Board Ver.C Power Control Board
  • ALSTOM NRD108034 8RDB44674G01 SA44674.C Control Card
  • ALSTOM N897092520B N897092057Y TRENO N897092500E
  • ALSTOM NRD108033 8RDC44667G01 SA44667.C Control Circuit Board
  • ALSTOM TRVC062105000 TRVC070938000 Series Specification
  • ALSTOM SDK-C0147 12004-101-00 SBS04M17C Control Module Technicals
  • ALSTOM N895313512X Digital Output Module
  • ALSTOM P70035W82V Feeder Protection Relay
  • ALSTOM N897164624A Digital Input Module
  • ALSTOM N897164611M Power Supply Module
  • ALSTOM N897164610L Communication Interface Module
  • ALSTOM N70032702L Protection Relay Module for Power Systems
  • ALSTOM MVAJ21L1GB0771B Voltage Protection Relay
  • ALSTOM MFAC34N1AA0001A Overcurrent Protection Relay
  • ALSTOM MCTI40N1AB0751G Current Differential Protection Relay
  • ALSTOM MCGG22L1CB0753E Overcurrent Protection Relay
  • ALSTOM MVAW 11B1AB0513A Trip Circuit Supervision Relay
  • ALSTOM MVTU 11K1CD0751G Voltage Transformer Supervision
  • ALSTOM MVAJ27L1FB0784D High Speed Tripping Relay Guide
  • ALSTOM MAVS01L1AB0501D Voltage Selection Relay Documentation
  • ALSTOM MVAW11B1AB9007A Trip Circuit Supervision Relay
  • ALSTOM MFAC14K1AA0001A Feeder Protection Relay
  • ALSTOM MCGG62N1CB0753F Generator Protection Relay
  • ALSTOM MAVS01L1AB0751D Protection Relay
  • ALSTOM PIB1201A 3BEC0067 Interface Module
  • ALSTOM V4555724-0100 Voltage Protection Relay
  • BENTLY 1900/65A-01-01-03-00-01 Monitor
  • BENTLY 3500/42-01-00 Proximitor Monitor
  • BENTLY 3500/54-03-00 Temperature Monitor
  • BENTLY 163179-02 Accelerometer
  • BENTLY 3500/94 145988 Display
  • Bently Nevada 1X35668 Replacement Internal Component Analysis
  • Bently Nevada 3500/22M 138607/01 Transient Data Interface
  • Bently Nevada 3500/40M 135489-04 Proximitor Monitor Module
  • Bently Nevada 3500/40M 125680-01 Proximitor Monitor
  • Bently Nevada 3500/15 127610-01 Power Supply Module
  • Bently Nevada 1900/65A-00-01-01-01-01 Machinery Monitor
  • Bently Nevada 3500/65 145988-02 Temperature Monitor
  • Bently Nevada 330876-03-50-00-00 Proximity Probe
  • BENTLY 3500/93 135785-02C System Display Module
  • BENTLY 3701/55 323174-01 ADAPT Input/Output Module
  • BENTLY 3500/42M 140734-99 Modification Module
  • BENTLY 3701/55 289761-01 ADAPT Emergency Shutdown Device
  • BENTLY 3500/42M 140734-02 Proximitor Seismic Monitor
  • BENTLY 3500/15 114M5330-01 Power Supply Module
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 3500/93 135799-01 LCD Display Module
  • BENTLY 3500/22 Transient Data Interface Module
  • BENTLY 9200-01-01-10-00 General Purpose Monitor
  • BENTLY 3500/65 145988-02 Temperature Monitor
  • BENTLY 1900/65A 172323-01 General Purpose Monitor
  • BENTLY 3500/22M 138607-01 Transient Data Interface
  • BENTLY 149986-01E 3300 XL 8mm Proximity Probe
  • BENTLY 1900/65A-01-01-03-00-01 General Purpose Monitor
  • BENTLY 136719-01 3500/92 Communication Gateway I/O
  • BENTLY 3500/22-01-01-00 Transient Data Interface Module
  • BENTLY 3500/22M 288055-01 Transient Data Interface
  • BENTLY 131151-01 3500/50 Tachometer I/O Module
  • BENTLY 1900/65-00-01-03-01-01 General Purpose Monitor
  • Bently Nevada 3500/54 133396-01 Overspeed Detection Monitor
  • Bently Nevada 3500/45 176449-04 Position Monitor
  • Bently Nevada 3500/42 140471-01 Proximitor Monitor
  • Bently Nevada 3500/94 147663-01 VGA Display Module
  • Bently Nevada 3500/42M 140482-01 Proximitor Monitor
  • BENTLY 3500/53 133396-01 Relay Module (Alternate Version)
  • BENTLY 3500/20 125744-01 Rack Interface Module
  • BENTLY 3500/53 133388-01 Relay Module
  • BENTLY 3500/15 114M5335-01 Power Supply Module
  • BENTLY 3500/40M 140734-01 Proximitor Monitor Module