Located on the side of the device, supporting SDSC and SDHC cards (compliant with SDA 2.0 specifications):

Insertion: Push into the card slot until you hear the sound of the card entering

Remove: Push the card back into the limit position and then pull it out

Attention: The SD card must be plugged in and out while the device is powered off to ensure that no program is writing to it

6.2 USB interface

USB Host(Type A):

Used to connect external devices such as USB drives, mice, keyboards, etc

Output capacity: 500mA (full power)

Only for maintenance work in industrial environments

USB Device(Type B):

Used to connect to the upper computer for data transmission or debugging

Recommend using a shielded USB cable with a maximum length of 5m

6.3 Ethernet interface

Interface type: RJ45, 8-pin, with 2 LED indicator lights

Green LED: lit to indicate link connection (LINK)

Yellow LED: flashing indicates data transmission in progress

Technical specifications:

Support speed: 10/100 Mbit/s, adaptive

Cable requirements: shielded twisted pair (STP) CAT5e/6

Mechanical protection: Avoid strong vibrations and tensile forces

Functional differentiation:

Ethernet 1: Can be used as a communication interface or real-time fieldbus interface

Ethernet 2 (C00 model only): Used only as a communication interface, no real-time requirements

6.4 RS-232 interface (COM1)

9-pin D-Sub plug (male), non electrically isolated:

Pin definitions: DCD (1), RXD (2), TXD (3), DTR (4), GND (5), DSR (6), RTS (7), CTS (8), RI (9)

The relationship between maximum baud rate and line length:

2.5m:115200 bit/s

5m:57600 bit/s

10m:38400 bit/s

15m:19200 bit/s

30m:9600 bit/s

6.5 RS-485 interface (COM2)

9-pin D-Sub plug (male), non electrically isolated:

Pin definitions: DATA+(3), DATA - (7), GND (5)

Attention: Pin 6 (5V) is strictly prohibited from being used as an external device power supply

Bus specification:

Characteristic impedance: 120 Ω

Allowable impedance range: 108-132 Ω

Maximum line length: 1200m

Maximum number of nodes per segment: 32

Both ends must be connected with 120 Ω terminal resistors

6.6 CAN interface

9-pin D-Sub plug (male), compliant with CiA standards:

Pin definitions: CAN-L (2), GND (3), CAN-H (7)

Pin 3 (CAN-GND) is internally connected to Pin 6 (GND)

The power supply for the CAN bus driver is provided internally by the device and cannot supply power to external devices

Bus specification:

Characteristic impedance: 120 Ω

Allowable impedance range: 108-132 Ω

Unit length capacitance:<60 pF/m

The relationship between maximum wire length and wire diameter:

100m:≥0.25mm²

250m:≥0.34mm²

500m:≥0.75mm²

Software and System Integration

7.1 Operating System

The XV300 series uses the Linux operating system, providing users with an open and stable software platform. The system supports multiple programming languages and development environments, making it easy to port and develop applications.

7.2 Visualization software

The device can be optionally authorized with GALILEO visualization software (order number suffix -2B or -2C). GALILEO is Eaton's advanced HMI development tool that supports:

Rich graphic elements and animation effects

Multilingual management

Formula management and data recording

Alarm and historical event handling

Multiple PLC driver protocols

7.3 Embedded PLC Functions

The model with PLC function (suffix -2C) integrates the CoDeSys soft PLC runtime system and supports all five programming languages of IEC 61131-3 (LD, FBD, ST, IL, SFC). This enables XV300 to serve as both HMI and controller, simplifying the system architecture and reducing hardware costs.

7.4 Communication Protocol Support

Through Ethernet and serial interface, XV300 can communicate with various brands of PLCs, supporting protocols including but not limited to:

Modbus TCP/RTU

CANopen

J1939

Various proprietary PLC drivers (to be configured in GALILEO)


Safety precautions and maintenance

8.1 Important safety warnings

Explosion hazard:

The equipment shall not be used to plug or unplug connectors with electricity in hazardous and explosive environments

Improper handling of internal lithium batteries may cause explosions and must be professionally disposed of

Electrostatic discharge:

Before coming into contact with the equipment, it is necessary to release static electricity from the human body

Avoid touching static sensitive components (such as connector pins)

Electromagnetic compatibility:

Professional assembled shielded cables must be used

Signal lines and power lines should be wired separately

All connectors need to be tightened or locked to improve shielding effectiveness

Condensation hazard:

Equipment may experience internal condensation after experiencing environmental fluctuations

It is strictly prohibited to turn on the machine when there is condensation

The equipment should be adapted to the ambient temperature before being put into operation

8.2 Daily Maintenance

Cleaning:

Clean the touch screen with a clean, soft, damp cloth

Prohibit the use of sharp or hard objects

Prohibit the use of corrosive or abrasive cleaning agents

Touch screen calibration:

If the touch response is inaccurate, it can be calibrated through the Linux system

Please refer to the Linux system description document for specific methods

  • National Instruments cRIO-9112 Chassis
  • National Instruments PXIe-1078 Chassis
  • National Instruments PCIe-6536 DIO Board
  • National Instruments NI-9425 Input Module
  • National Instruments PCI-5122 Digitizer Card
  • National Instruments 779072-01 Relay Module
  • National Instruments 783703-01 DAQ Module
  • National Instruments PXI-6515 Digital Module
  • National Instruments 781099-01 DAQ Device
  • National Instruments PXI-8183 PXI Controller
  • National Instruments sbRIO-9626 Single-Board RIO Controller
  • National Instruments PXIe-1435 Camera Link Frame Grabber
  • National Instruments NI 9237 Strain Bridge Input Module
  • National Instruments PXIe-4353 Thermocouple Input Module
  • National Instruments PCIe-6320 X Series DAQ Card
  • National Instruments NI 1454 Compact Vision System
  • National Instruments PCIe-6321 X Series DAQ Card
  • National Instruments PXIe-5172 PXI Oscilloscope Module
  • National Instruments cDAQ-9134 CompactDAQ Controller
  • National Instruments cRIO-9063 CompactRIO Controller
  • National Instruments PXI-4070 DMM Card
  • National Instruments cFP-BP-4 Backplane
  • National Instruments 779521-01 Bridge Module
  • National Instruments cDAQ-9172 Chassis
  • National Instruments NI 9236 Strain Module
  • National Instruments PXI-1042Q Chassis
  • National Instruments SCXI-1102 Input Module
  • National Instruments 776990-01 Input Module
  • National Instruments PXI-1045 PXI Chassis
  • National Instruments PCIe-6251 DAQ Device
  • National Instruments NI 9219 Universal Analog Input Module
  • National Instruments NI 9215 BNC Analog Input Module
  • National Instruments PXIe-6570 Digital Pattern Instrument
  • National Instruments NI-9477 Digital Output Module
  • National Instruments NI 9145 EtherCAT Chassis
  • National Instruments PCI-6521 Industrial Digital I/O Card
  • National Instruments NI 9239 BNC Voltage Input Module
  • National Instruments NI 9265 Current Output Module
  • National Instruments NI 9212 Thermocouple Input Module
  • National Instruments PXI-6229 Multifunction DAQ Module
  • National Instruments NI-9146 Chassis
  • National Instruments PXIe-5622 Digitizer
  • National Instruments PXI-6704 Output Module
  • National Instruments 782362-01 Input Module
  • National Instruments 779068-01 Digital Module
  • National Instruments 781063-01 Output Module
  • National Instruments PCI-7356 Motion Controller
  • National Instruments 779787-01 Input Module
  • National Instruments PXIe-1071 System
  • National Instruments NI 9219 Input Module
  • National Instruments NI 9214 Thermocouple Input Module
  • National Instruments PXIe-1085 18-Slot Chassis
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments USB-6211 Multifunction I/O Device
  • National Instruments USB-6341 X Series DAQ Device
  • National Instruments NI 9205 Analog Input Module
  • National Instruments NI 9149 8-Slot Chassis
  • National Instruments PXIe-2569 Relay Module
  • National Instruments NI 9230 Sound and Vibration Module
  • National Instruments cRIO-9047 CompactRIO Controller
  • National Instruments PCI-6534 Digital IO Card
  • National Instruments PXI-5122 Digitizer Module
  • National Instruments cDAQ-9188XT Chassis
  • National Instruments cDAQ-9184 Ethernet Chassis
  • National Instruments USB-6225 OEM DAQ Device
  • National Instruments NI 9205 Input Module
  • National Instruments NI 9207 Input Module
  • National Instruments NI-9862 CAN Module
  • National Instruments 781156-01 CAN Module
  • National Instruments FP-AO-200 Output Module
  • National Instruments NI 9264 Output Module
  • National Instruments IC-3173 Controller
  • National Instruments NI 9234 Vibration Module
  • National Instruments SMB-2163 DIO Accessory
  • National Instruments PXIe-1062Q DSA System
  • National Instruments USB-6289 DAQ Device
  • National Instruments NI 9233 Vibration Module
  • National Instruments PXIe-5840 VST
  • National Instruments PXI-1033 and PXI-6132 System
  • National Instruments GPIB-USB-HS+ Controller
  • National Instruments NI 9231 Sound and Vibration Module
  • National Instruments cRIO-9074 CompactRIO Controller
  • National Instruments 782536-01 DAQ Module
  • National Instruments 779781-01 DAQ Module
  • National Instruments PXIe-8388 MXI Express Controller
  • National Instruments SCXI-1520 Strain Bridge Module
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments NI 9234 Sound and Vibration Module
  • National Instruments USB-4431 Sound and Vibration Device
  • National Instruments NI 9227 Current Input Module
  • National Instruments PXI-1033 PXI Chassis
  • National Instruments NI 9213 Thermocouple Module
  • National Instruments PXI-1042 PXI Chassis
  • National Instruments PXI-6229 DAQ Card
  • National Instruments cRIO-9075 Controller
  • National Instruments PCI-6033E DAQ Card
  • National Instruments PCIe-6363 DAQ Card
  • National Instruments cDAQ-9174 Chassis
  • National Instruments PXIe-8880 PXI Controller
  • National Instruments NI 9242 Analog Input Module
  • National Instruments USB-6221 BNC DAQ Device
  • National Instruments NI 9220 Analog Input Module
  • National Instruments cRIO-9068 CompactRIO Controller
  • National Instruments PXI-4130 Source Measure Unit
  • National Instruments USB-6251 Multifunction DAQ Device
  • National Instruments PXI-8106 Embedded Controller
  • National Instruments USB-6218 Multifunction DAQ Device
  • National Instruments PCIe-1473R Camera Link Frame Grabber
  • National Instruments PXIe-4341 DSA Module
  • National Instruments PXI-8102 Embedded Controller
  • National Instruments cDAQ-9178 Chassis
  • National Instruments USB-6210 DAQ Device
  • National Instruments USB-6212 DAQ Device
  • National Instruments NI 9485 Relay Output Module
  • National Instruments NI 9208 Current Input Module
  • National Instruments PXIe-4141 SMU
  • National Instruments PCI-6154 DAQ Card
  • National Instruments cRIO-9038 Controller
  • National Instruments PCI-6133 DAQ Card
  • National Instruments LabVIEW RIO Kit 501684G
  • National Instruments PXIe-6396 Embedded Controller
  • National Instruments USB-8502 CAN Interface Device
  • National Instruments NI 9264 Spring Terminal Output Module
  • National Instruments NI 9213 Thermocouple Input Module
  • National Instruments NI-9205 Analog Input Module
  • National Instruments NI 9264 Analog Output Module
  • National Instruments USB-6212 Multifunction I/O Module
  • National Instruments PXI-4071 FlexDMM Multimeter Module