Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Kollmorgen SERVOSTAR-CD servo drive hardware installation and system configuration

F: | Au:FAN | DA:2026-02-10 | 963 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Kollmorgen SERVOSTAR-CD servo drive hardware installation and system configuration

1. Product Overview and Safety Standards

Danaher Motion's SERVOSTAR ®  Since its launch in 1997, the CD series digital servo motor driver has become a mature solution in the field of industrial motion control. This series is divided into the early CD Series 2 (model number 5 is 2, such as CR06250) and the more powerful CD Series 5 (model number 5 is 5, such as CR06550). Series 5 is backward compatible with Series 2 in terms of hardware and functionality, and integrates more advanced digital signal processor (DSP) control technology, additional I/O, and a lower cost rotary transformer conversion solution, making it the preferred choice for new applications.

Safety is the primary prerequisite for installation and operation. This equipment is only allowed to be transported, assembled, debugged, and maintained by qualified personnel. Operators must be familiar with the installation and commissioning standards of motors and related equipment (such as IEC 364, DIN VDE 0100), and strictly comply with safety regulations. The equipment contains electrostatic sensitive components, which require electrostatic discharge before operation and avoid contact with high insulation materials. When powered on, do not plug or unplug the connector. After power off, wait for at least 10 minutes to ensure that the capacitor is fully discharged. If necessary, use an electric meter to measure and confirm.

The equipment has passed UL/cUL 508C certification (applicable to the US and Canadian markets) and meets the CE marking requirements of the European Union, including the Machinery Directive (89/392/EEC), Electromagnetic Compatibility Directive (89/336/EEC), and Low Voltage Directive (73/23/EEC). To ensure that the entire system complies with EMC standards, the machine manufacturer is responsible for the EMC compliance of the final system and strictly follows the installation recommendations in this document, especially the guidance on shielding, grounding, filter layout, and cable laying.


2. Hardware installation and environmental requirements

SERVOSTAR-CD drivers are designed for panel installation and should be placed in metal cabinets to ensure appropriate protection levels (such as IP30) and electromagnetic compatibility. Attention should be paid during installation:

Vertical installation for better heat dissipation.

Ensuring metal to metal contact between the driver's metal casing and backplate is crucial for controlling electrical noise, optimizing grounding, and EMC performance.

The installation backplate should be an unpainted metal surface to provide optimal electrical bonding and low impedance grounding path.

Adequate clearance distance should be maintained laterally and at the top/bottom (such as approximately 0.5 inches for lateral 16/14 AWG cables) to ensure heat dissipation and safety.

The hardware specifications vary depending on the model (Cx03, Cx06, Cx10), including weight, installation torque, connection screw specifications, and recommended wire diameters (such as 16 AWG/1.5 mm ² for control logic wires and 14 AWG/2.5 mm ² for motor power wires).


3. System wiring, grounding, and shielding technology

Proper wiring, grounding, and shielding are crucial for the long-term stable operation of the system and compliance with EMC standards.

3.1 General Wiring Principles

Separation of strong and weak electricity: Control and signal cables should be laid separately from power and motor cables, with a recommended minimum spacing of 20 centimeters. If crossing is necessary, it should be done at a 90 ° angle to minimize coupling interference.

Use shielded cables: All control and signal cables should be shielded to reduce radiated interference.

Cable laying: Power lines should be placed as close as possible to the backplane to allow for capacitive coupling of noise and current to the grounding plane. When the motor cable and feedback cable exit the cabinet, they should be separated as much as possible, ideally using separate metal tubes.

3.2 Grounding System

The system grounding needs to achieve two goals: safe grounding and high-frequency grounding.

Safe grounding: All system component frameworks must be connected to the ground through a star shaped grounding point.

High frequency grounding: provides an extremely low impedance grounding path for filters, drivers, and power supplies. Do not use ordinary wires as high-frequency grounding, as their inherent inductance will generate impedance at high frequencies. Flat braided tape or copper bars should be used and the length should be shortened as much as possible. The backplane needs to be connected to the cabinet frame and ground through a high-frequency grounding strip.

3.3 Shielded cable overlap

All shielding layers of shielded cables (motors, feedback cables) must be overlapped near the driver end to reduce the impedance between the shielding layer and the backplane, thereby suppressing noise emission and improving immunity.

Method 1: Use non insulated metal cable clamps to directly clamp the exposed shielding layer onto the backplate.

  • Micro Innovation GF1-10TVA-100 Touch Panel
  • Micro Innovation GSO-57EQD-000 Operator Panel
  • Micro Innovation XN-2AI-U Analog Input Module
  • Micro Innovation CAN-4AI/UI Analog Input Module
  • Micro Innovation ZSB-1.5/8-S/S/-/PE Base Terminal
  • Micro Innovation AG XVH-340-57CAN-1-10 HMI Panel
  • Micro Innovation GSO-57EQD-000 Micro Panel
  • Micro Innovation XN-2AI-PT/NI-2/3 Input Module
  • Micro Innovation AG GF0-57SQD-000 Display Panel
  • MICRO INNOVATION AG XN-16DI-24VDC-P Input Module
  • Micro Innovation XN-2AI-PT/NI-2/3 Input Module
  • Micro Innovation MC2-442-57CQB-1-2G Display Panel
  • Micro Innovation XN-16DO-24VDC-0.5A-P Module
  • Micro Design MC200PROFI Programmable Module
  • Micro Innovation XV-252-57MPN-1-10 Micro Panel
  • Micro Innovation CAN-4AI/UI Analog Input Module
  • Micro Innovation GT1-MPI-A000 Panel
  • Micro Innovation MC2-440-10TVB-1-21 Display Panel
  • Micro Innovation XVS-430-57MPI-1-1S 6" HMI
  • Micro Innovation XV-442-57CQB-1-1AB Monitor
  • Micro Innovation ZSB-1.5/8-S/S/-/PE Base Terminal
  • Micro Design 895A Microfiche Reader
  • MICRO INNOVATION XNE-8DI-24VDC-P Input Module 8550100794
  • MICRO INNOVATION MICRO PANEL GF0-10CVD-002
  • Micro Innovation XN-PLC-CANopen Controller 85 50 274124
  • Micro Innovation Display Panel GS0-57E0D-000
  • MICRO INNOVATION CAN-32DI/P2X16 Input Module
  • MICRO INNOVATION XN-2DO-R-NO Relay Output Module
  • MICRO INNOVATION XNE-16DI-24VDC-P Input Module
  • Micro Innovation AG XN-2AI-U Analog Input Module
  • Micro Innovation XN-BR-24DC-D Power Supply
  • Micro Innovation MH2-342-57EIB-1-20 Panel
  • Micro Innovation XV-252-57MPN-1-10 Micro Panel
  • Micro Innovation Display Card EIB2-TP
  • Micro Innovation XV-252-57MPN-1-10 6" HMI
  • Micro Innovation XN-B3T-SBC 16x DO Base Module
  • Micro Innovation XVH-330-57MPI-1-10 Panel
  • Micro Innovation XN-BR-24VDC-D Power Module
  • Micro Innovation EIB2-TP EIB2TP Module
  • Micro Innovation GF0-10CVD-100 Touch Panel
  • MICRO INNOVATION XV-230-57CNN-1-10 HMI-PLC
  • MICRO INNOVATION XN-2DO-R-CO Relay Output Module
  • KMK MICRO INNOVATION GS2-90EMD-000 Micro Panel
  • Micro Innovation XN-2AO-U Analog Output Module
  • Micro Innovation XN-1AO-I Analog Output Module
  • Micro Innovation CAN-32DI/P-2x16 Rack Module
  • Eaton Micro Innovation MC2-440-10TVB-1-11 HMI
  • Micro Innovation AG CAN Bridge 8551224177
  • Micro Innovation XN-2AI-I Analog Input Module Set
  • Micro Innovation XN-4DI-24VDC-P Input Module
  • Micro Innovation Winbloc CAN-16DO/0.5A-PK Module
  • Micro Innovation Micro Panel GFO-10SVD-002 HMI
  • Micro Innovation CAN-24DI/8DO/0.5A-PK Module
  • Micro Innovation DP-24DI/8DO/0.5A-PK I/O Module
  • Weidmuller Micro Innovation CAN-BRIDGE ZSFA 1,5R
  • Micro Innovation CAN-3AI/1AO-UI Profibus Module
  • Micro Innovation PDP-TP Profibus DP Module
  • Micro Innovation CAN-3AI/1AO-UI Analog Module
  • Micro Innovation MC2-430-12TSB-10 HMI Panel
  • Micro Innovation XNE-8DO-24VDC-0.5A-P I/O Module
  • MICRO INNOVATION AG WINBLOC CAN-32DI/P-2x16 85 51 224182
  • MICRO INNOVATION AG WINBLOC CAN-4AO/UI 85 51 224195
  • Micro Innovation Xv-252-57cnn-1-10 HMI Panel
  • Micro Innovation XN Basis XN-S4T-SBBS-CJ 225200
  • Micro Innovation GF1-10TVD-100 Micro Panel
  • Micro Innovation XN-B3T-SBC 16-Fold DO Base Module
  • MICRO INNOVATION AG WINBLOC CAN-3AI/1AO-UI 85 51 224192
  • KMK Micro Innovation GS2-90EMD-000 Micro Panel
  • Micro Innovation MC2-430-10TVB-1-10 PanelView Terminal 24VDC
  • Micro Innovation XNE-8DO-24VDC-0.5A-P I/O Module 8550100795
  • MICRO INNOVATION GF1-10TVB-100 Touch Panel
  • MICRO INNOVATION AG WINBLOC CAN-4AI/UI Analog Input Module
  • MICRO INNOVATION AG WINBLOC CAN-32DO/0.5A-P-2x16 Output Module
  • MICRO INNOVATION AG CAN-32DI/P-2X16 8551224182 Input Module
  • MICRO INNOVATION MK2-230/232-57 Circuit Board 85 28 200000
  • MICRO INNOVATION CAN-BRIDGE 8551224177 CAN Bridge
  • Micro Innovation MC2-430-10TVB-1-10 Panel 24VDC
  • MICRO INNOVATION MC2-432-57CQB-1-10 HMI Panel
  • MICRO INNOVATION AG CAN-BRIDGE 85 51 224177 CAN Bridge
  • MICRO INNOVATION CAN-4AI/UI Analog Input Module
  • MICRO INNOVATION CAN-32DI/P-2X16 Input Module
  • SIGMATEK MDD111 09-404-111 Drive Module
  • SIGMATEK DVI021 Display Interface Module
  • SIGMATEK 00-450-024 C-IPC Processor
  • SIGMATEK MDD-111 MDD111 Drive Module
  • SIGMATEK ICA011 20-102-011 Interface Module
  • SIGMATEK 01-250-010-D NC4Kompakt Control Module
  • SIGMATEK CRIF081 12-751-081 Interface Module
  • SIGMATEK S1026-8AF61-R4E-Z57 Drive Module
  • SIGMATEK 9305.081.02 9227.082.00 Control Module
  • Sigma Tek 5000B-36 Attitude Indicator
  • SIGMATEK CEZ201 12-051-201-O Counter Module
  • SIGMATEK DPS001 Power Supply Module
  • SIGMATEK 994 395 01z Via Interface Module
  • SIGMATEK PC411-K 01-310-411-K Industrial PC
  • SIGMATEK 9816.324.00 Demag NC4 Keyboard
  • SIGMATEK ET261 90010C-71 Operator Terminal
  • SIGMATEK DDI 164 05-006-164 Input Module
  • SIGMATEK CCP 082 C-DIAS Processor Module
  • SIGMATEK CEZ201 12-051-201-O PLC Module
  • SIGMATEK MDD 1111 06178867 Drive Module
  • SIGMATEK S1 073-6AC61-RE-Y08-Z Drive Module
  • SIGMATEK MDD 111 Drive Module MDD111
  • SIGMATEK CSDI161 Safety Module 12-891-161
  • SIGMATEK C-IPC Processor 01-450-024
  • SIGMATEK DIAS DAM122 Analog Mixing Module
  • Sigma Tek 5000B-36 Attitude Gyro Indicator
  • SIGMATEK TMS012 Motherboard Module 05-250-012-T
  • SIGMATEK CCP-531 PLC Module
  • SIGMATEK DIAS DNC4 I/O Module 05-250-011
  • SIGMATEK AI088 Analog Input Module
  • SIGMATEK CEZ201 Counter Module
  • SIGMATEK CIC011 Industrial Computer Module
  • SIGMATEK MDM021 Motor Drive Module
  • SIGMATEK DTO163 Digital Output Module
  • SIGMA-TEK 5000B-36 Attitude Gyro
  • SIGMATEK DM161 Digital Input Module
  • SIGMATEK CCP-531 PLC Control Panel
  • SIGMATEK HZS773 Touch Terminal Operator Panel
  • SIGMATEK MDP101 3 KVA 45-65Hz Driver
  • SIGMATEK ETV1251 Touch Panel 12-230-1251
  • SIGMATEK CIO021 Safety Module 12-013-021
  • Sigma Tek 4000H-5 Directional Gyro
  • SIGMATEK TAE531 I/O Module 01-240-531
  • SIGMATEK DAI081 Input Module 05-009-081
  • SIGMATEK DCP640 Drive Control Module
  • SIGMATEK DCP643 Slides Module A6-29
  • SIGMATEK SCP011 Safety Module 20-890-011