Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

How to determine if the GE MLJ synchronous check relay is in calibration mode?

来源: | 作者:FAN | 发布时间 :2025-08-12 | 14 次浏览: | Share:

How to determine if the GE MLJ synchronous check relay is in calibration mode?

Product Overview

Core functions

MLJ is a digital synchronous inspection relay mainly used to detect the synchronization conditions of two electrical systems (such as the generator and the power grid, and the two sections of the power grid). By measuring the voltage difference (Δ V), frequency slip (Δ f), and phase angle difference (Δθ) between the bus voltage (VB) and the line voltage (VL), it determines whether the circuit breaker closing conditions are met and outputs a closing permission signal.

Typical application scenarios

Generator and system grid connection

Reconnect the two regions of the system

Manual closing or automatic reclosing of circuit breakers

Verify synchronization conditions to avoid equipment damage caused by asynchronous closing

Core functions and working principles

1. Synchronous inspection unit

Measurement parameters:

Voltage difference (Δ V): The absolute difference in voltage between the bus and the line, ranging from 2-90V (default 15V).

Phase angle difference (Δ θ): The phase difference between two voltages, ranging from 2-60 ° (default 10 °).

Frequency slip (Δ f): The frequency difference between two voltages, ranging from 10-500MHz (default 20mHz).

Working mode:

Continuous mode: Continuous monitoring of synchronization conditions, with a delay of 0.1-99.0s (default of 0.1s) before allowing the output to close.

Manual mode: Monitoring is triggered by external signals, and after a delay of 0.1-99.0s (default 10.0s), the output allows for closing.

Allowable conditions for closing: Δ V, Δ θ, and Δ f are all less than the set values and continuously meet the set delay.

2. Undervoltage unit

Independently monitor the voltage status (live/dead) of lines and busbars, supporting three combination modes:

DLDB (Loss of Line - Loss of Power Bus)

DLLB (Lost Line - Live Bus)

LLDB (Live Line - Dead Bus)

Voltage thresholds can be set: line/bus live threshold (VL ↑/VB ↑, 40-245V), and power-off threshold (VL ↓/VB ↓, 10-180V).

3. Input/output unit

Digital input: 3-channel DC input, including circuit breaker status (allowing synchronous check when open), manual mode trigger, and enable signal.

Output contacts: 5-way relay contacts, including 2-channel closing permission (default normally open), 1-channel alarm (default normally closed), and 2-channel configurable auxiliary contacts (supporting signal outputs such as synchronization, undervoltage, and power loss).

4. Self check and Communication

Continuously monitor memory (ROM/RAM/EEPROM), analog circuits, etc., output alarms and display error codes when faults occur (e.g. 8.0 indicates ROM failure).

Supports RS-485 communication (optional fiber optic interface), baud rate 0.3-38.4kbaud (default 9.6kbaud), and supports Modbus protocol.

Technical specifications

Electrical parameters

Rated voltage: 63-220Vac (continuous withstand 440Vac).

Auxiliary power supply: 24-48Vdc, 48-125VDC, 110-250Vdc (± 20% fluctuation).

Measurement accuracy: Voltage ± 2% or 0.5V; Angle ± 1 ° (at 20-220Vac); Frequency slip ± 5mHz.

Contact capacity: Closing allows contact 4000VA (maximum 440Vac/300Vdc), auxiliary contact 1760VA.

Environmental and Physical Characteristics

Working temperature: -25 ° C to+55 ° C, storage temperature: -40 ° C to+70 ° C.

Humidity: ≤ 95% (no condensation).

Shell: Made of steel plate material, supporting panel installation or MID system integration, weighing approximately 3kg.


Operation interface and navigation

1. Front end devices

Button: Three vertically arranged buttons, from top to bottom, are ENTER (confirm/enter),+(add/next), and - (decrease/previous).

Display: A 3-digit 7-segment LED display screen used to show parameter values, status codes, and settings.

Indicator lights: 3 LED indicator lights, namely:

READY (green): The relay is ready and the protection function is enabled.

52 (red): The conditions for closing are met.

27 (red): The undervoltage condition is met.

2. Switching between working modes

Reading mode: default power on mode, displaying real-time data and status. Press ENTER to cycle through the various functional items (F0-F12).

Setting mode: In read mode, press ENTER and - simultaneously to enter and modify parameters. After setting up, press+and - simultaneously to return to read mode; If there is no operation for 2 minutes, it will automatically return.

Calibration mode: In reading mode, press ENTER and+simultaneously to enter and display the average values of line voltage and bus voltage for calibration.

Read mode function (F0-F12)

The main functions of cycling through the ENTER key include:

Functional code description

The F0 relay status displays a two digit error code (such as 0.0 indicating normal, 8.0 indicating ROM fault), with the decimal point constantly lit to distinguish the status from the numerical value.

Real time display of RMS voltage value in V for F1-F2 line voltage (VL)/bus voltage (VB).

F3 voltage difference (Δ V) displays the absolute difference between VL and VB, measured in V.

F4 phase angle difference (Δ θ) displays the phase difference between two voltages (0-180 °), and overflow (three horizontal lines) is displayed when the voltage is less than 9V.

  • Applied Materials 0100-35218 - Amat RF Gn rateur Board
  • Applied Materials 4060-01365 - AMAT Heat Exchanger Hoses Make Offers!UPS Shipping!
  • Applied Materials 0040-88097 - , 0040-88188 HEATER, HA12 VACUUM CHUCK, 300MM SACVD P AMAT
  • Applied Materials 0020-99268 - INNER SHIELD / AMAT
  • Applied Materials 0010-47964 - 304-0201 AMAT APPLIED APPLIED MATRIALS COMPONENTS
  • Applied Materials 0010-25273 - AMAT FAST DATA COLLECTOR
  • Brooks GF125CXXC - GF125C-102465 N2 10 SCCM MFC AMAT 0190-41803 MASS FLOW
  • Applied Materials 0010-08113 - AMAT ASSY, INPUT GRIPPER, UPGRADE, 200MM MESA
  • Applied Materials 0021-35008 - AMAT PLATE, REFLECTOR, 200MM, MOD II
  • Applied Materials 0190-03554 - AMAT MAG DRIVER, 50A, 2-CHANNEL, KOLLMORGEN 1000-0121-01
  • Applied Materials 0020-08673 - AMAT SHIELD, INNER, AL ARC-SPRAY SST, SIPM
  • Applied Materials 0090-09242 - (AMAT) COIL, MAGNET, SIDE
  • Applied Materials 0244-00027 - AMAT QUIMONDA 20K CHAMBER-1-30-2008 R2 / 3700-02724, 3700-03473
  • Applied Materials 0190-35864 - AMAT AC Inout Cable, 2015P-MS Connector
  • Applied Materials 3870-03835 - ISO VALVE, EXHAUST THROTTLE / AMAT
  • Applied Materials 0190-09328 - HEAT SHIELD CHAMBER A ISOLATION VALVE AMAT
  • Applied Materials 3930-00005 - AMAT DPS VAT PM-7E CONTROLLER ASSY
  • Applied Materials 0100-09245 - AMAT PCB ASSY 2PH STEP M DRIVER INTF BD
  • Applied Materials 0010-09022 - AMAT SLIT VALVE ASSY
  • Kensington M4000 - Newport Servo Positioning Controller Robot AMAT 0190-23563W
  • Applied Materials 453012 - AMAT In-Situ Particle Monitor
  • Applied Materials 0010-50867 - 215-0202 AMAT APPLIED (#2) 0010-50866 0010-42855
  • Applied Materials 0015-09055 - BELLOWS ASSY SUSCEPTOR HOLLOW / AMAT
  • Applied Materials 0190-25889 - AMAT SBC P1.0GHZ, 512MB RAM, 100GB HD 3U CPCI , AS IS
  • Applied Materials 0010-00685 - ACTUATOR ASSY STD CATHODE AMAT
  • Applied Materials 3620-00342 - AMAT PUMP PNEU 6 GPM 60 PSI 1/2
  • Applied Materials 0190-76273 - 303-0201// AMAT APPLIED DRIVER, PVD LAMP/HEATER DRIVER
  • Applied Materials 0040-75151 - FILLER CHAMBER APF / AMAT
  • Applied Materials 0090-77053 - TRANSDUCER,PRESSURE / AMAT
  • Applied Materials 0020-19258 - AMAT PEDESTAL TITANIUM 300MM PCII (4)
  • Applied Materials 0020-36036 - AMAT HOUSING MAGNETIC REV002
  • XP Power 102320-01 - Applied Materials AMAT 0195-14725 Control Box
  • Applied Materials 0100-13024 - AMAT ASSY, PCB INTERFACE PROCESSOR DIST.
  • Applied Materials 0010-03338 - applied materials WxZ heater pedestal 8" 0010-38328 0010-03372
  • Applied Materials 0010-30139 - ASSY,HV FILTER,DPS CHAMBER AMAT
  • Applied Materials 21016404077 - NEAT STAGE CONTROLLER / AMAT
  • VAT 601BS-29NN-0003/1263 - SERVICE BOX 2,AMAT PN: 3870-05773
  • Applied Materials 0040-23664 - PLATFORM, LEVEL / AMAT
  • Applied Materials 0020-37639 - AMAT WAFER LIFT ASSEMBLY RTP XE 200MM
  • Applied Materials 0020-28205 - 124-0101 AMAT APPLIED COVER RING, 6 101% HI-PWR COH [REFURBISHED]
  • Applied Materials 0010-16392 - ESC ASSY, 300MM, DUAL ELECTRODE, IA AMAT
  • Applied Materials 0190-24681 - TEMPERATURE CONTROLLER AMAT YAMATAKE
  • Applied Materials 0041-56873 - CHAMBER LID PLATE SPIRAL LID MALD / AMAT
  • Applied Materials 0190-34283 REV 2 - AMAT MKS AS01496-0-3
  • Applied Materials 0020-70336 - AMAT / FROG LEG ARM & WING SET
  • Applied Materials 0227-06385 - 103-0101// AMAT APPLIED ISOLATION TRANSFORMER W/TB, 20
  • Verity Instruments 1011240 - OFS Detector Module AMAT 0190-44813 Working Surplus
  • Applied Materials 0190-16235 - MOTOR/ENCODER, ROBOT, WET, SHOULDER, ASSY / AMAT
  • ICT 4916171 - PMT+PRE AMP In-Lens Detector AMAT Applied Materials
  • Applied Materials 4060-00930 - 215-0201 AMAT APPLIED APPLIED MATRIALS COMPONENTS
  • Applied Materials 0010-70321 - 123-0301// AMAT APPLIED ASSY, SLIT VALVE O-RING, CROWNED
  • Applied Materials 0020-20691 - 120-0501 AMAT APPLIED PEDESTAL CD/PT WAFER200 MM [REFURBISHED]
  • Applied Materials RF DOME MATCH - AMAT Centura DPS Poly Etch | AE PN: 3155086-102 Rev C
  • Applied Materials 0021-44786 - 209-0501 AMAT APPLIED APPLIED MATRIALS COMPONENTS
  • Applied Materials 0190-00970 - AMAT HT SCR POWER CONTROLLER 480VAC
  • Applied Materials 0100-00003 - AMAT VME STEPPER CONTROLLER,USED
  • Varian E11130733 - AMAT Ion implanter Computer PN:E11130733 / E19287563
  • Applied Materials 0190-18327 - AMAT ASSY, HOSE 50',SMC/AMAT1, MALE QD TO FEM
  • Applied Materials 0090-00925 - AMAT MOTOR ENCODER ASSY FOR LONG ROBOT MIRRA CMP 200MM
  • Verity SD2048DL - Amat APPLIED MATERIALS 0190-25450 Spectrometro
  • Applied Materials 0090-A3682 - AMAT PMT-100 DETECTOR ASSY
  • Applied Materials 0150-43931 - AMAT CABLE ASSY SLURRY LINE 3/4 RETROFIT , AN
  • Applied Materials 0240-27279 - Kit 3 Laser robot Char AMAT
  • Applied Materials 0190-13626 - 144-0401 AMAT APPLIED PURCHASE SPEC. CTI OBIS HE 8 FLEXLINE ME
  • Applied Materials 0010-29842 - AMAT ASSEMBLY, 300MM DBR HIGH TEMP BELT WRIST
  • Applied Materials EFEM IO CONTROLLER - EFEM IO CONTROLLER ENDURA
  • Kawasaki 30C65E-A010 - AMAT ROBOT CONTROLLER
  • Applied Materials 0100-77014 - AMAT CMP ENDPOINT CONTROLLER BD.
  • Applied Materials 4060-00937 - AMAT 16-PORT PNEUMATIC MANIFOLD ASSY EX420-SDN1
  • Applied Materials 0100-A2141 - BOARD
  • Applied Materials 0200-10390 - GDP, CHAMBER RPS / AMAT
  • Applied Materials 0190-15759 - AMAT SERVOMOTOR REFLEXION LK W/ 0020-63195 017PLX0220-XX-5597X
  • Applied Materials 0020-46516 - AMAT CLAMP, ROLLING SEAL, 200MM 5 ZONE PROFIL
  • Applied Materials 0010-11491 - AMAT 002 Heater *used working, clean surface*
  • Applied Materials 0100-00011 - PCB DRIVER CHOPPER AMT 0100000011 / AMAT
  • Applied Materials 0270-06857 - AMAT FIXTURE HANDLE WINDOW CLAMP
  • Applied Materials 0660-01660 - AMAT VGC 332140 CONVECTRON MODULE GAGE 3U CARD
  • Applied Materials 0020-35819 - 124-0401 AMAT APPLIED CHUCK, ASP, 200MM, TOP MOUNT TYPE
  • Applied Materials 0010-00298 - (AMAT) RF MATCH, ASSEMBLY AMAT 8300
  • Applied Materials 0040-86650 REV. 003 - AMAT RF COIL FOR ETCH CHMABER
  • Applied Materials 0021-29364 - QUARTZ KIT HOUSING / AMAT
  • Applied Materials 0010-09341 - 112-0203// AMAT APPLIED (#1) WAFER LIFT ASSY
  • Applied Materials 0041-25016 Rev 05 - Faceplate,AMAT,Used,US+97064
  • Applied Materials 0010-10245 - DC POWER SUPPLY BOX ASSY (24V AT 31A), AMAT
  • MKS CDN497 - Redesign Board AS00497-AB REV 02 CDN500R-10 0190-37771 AS01500-10
  • Applied Materials 0010-25482 - AMAT CHAMBER MODULE CONTROLLER
  • Applied Materials 1080-01809 - AMAT Servo Drive Module 0190-83793 REV 03
  • Applied Materials 0270-D5390 - 0270-D5390
  • KLA-Tencor 1530B-12-5000_SA - SensArray Calibration Tool, AMAT 1310-00070
  • Applied Materials 0090-04309 - AMAT ASSEMBLY, RF FILTER BOX, 200MM PRODUCER
  • Applied Materials 0190-07679 - AMAT Operator Interface Control Switch
  • Applied Materials 30712640100 - ASA ASSY / AMAT
  • Applied Materials 0010-20130 - BLADE ASSY 8 INCH BUFFER / AMAT
  • Applied Materials 0242-09033 - 322-0401 AMAT APPLIED KIT, CO H.O.T. PACK, 484NM [REFURBISHED]
  • Applied Materials 0040-36170 - AMAT EV Module Banner Relay DTLR Interlook 0110-09307
  • Applied Materials 0190-09419 - 303-0401 AMAT APPLIED DRIVE SINGLE PHASE, PHASETRONICS
  • Applied Materials 0040-18208 - Ultima ESC AMAT
  • Applied Materials 0200-08347 - AMAT Robot Blade, 453012
  • Applied Materials 300MM ENDURA - SOURCE ASSY AMAT
  • Applied Materials 0150-38496 - C/A RF GENERATOR DIGITAL I/O, 5200 IPS, AMAT
  • Applied Materials 0090-02788 - 212-0301 AMAT APPLIED ELECT ASSY, 300MM STD-PRECLEAN CHM INTER
  • Applied Materials 0100-01321 REV 009 - AMAT DIGITAL I/O BOARD (R3S3.3)
  • Applied Materials 0040-89462 - AMAT FLANGE, 6 PORT, 300MM TITAN CONTOUR
  • Applied Materials 0190-18128R - AMAT ASTEX D13449 Magnetron Head AG9131A 6.7KV 3.5KW
  • Applied Materials 0010-09933 - 320-0202 AMAT APPLIED HV MODULE ASSY, ESC
  • Applied Materials 0021-22583 - BUSHING RIGID COIL SUPPORT / AMAT
  • Applied Materials 9090-00986 - AMAT Part Number
  • Applied Materials 0040-75907 - 316-0402// AMAT APPLIED ARM, LEFT, VHP+ ROBOT NEW
  • Applied Materials 0020-27812 - AMAT PIN ALIGNMENT G-12 SOURCE FRAME Qty 2
  • Applied Materials 0010-01412 - ACTURATOR ASSY-SLIT LINER DOOR AMAT
  • Eaton PW5115 - 5115 1500i RM BLK 103003276-6591 AMAT APPLIED MATERIALS 0190-26019-
  • Applied Materials 0010-03151 - AMAT ASSY, ELECTRONIC BOX, BRUSH, 300 MM HVM
  • Applied Materials 0150-00743 - AMAT Pyrometer 2mm Probe 300mm Radiance Working
  • Applied Materials 0190-09459 - CABLE ASSY, FIBER OPTIC 20 FT AMAT
  • Applied Materials 0040-75445 - AMAT WRIST ASSY, ROBOT / AMAT
  • Applied Materials 0195-15018 - AMAT SUPER SET MF CIOC
  • Applied Materials 0190-09764 - AMAT ZERO FIRING VARIABLE TIME BASE SCR POWER
  • Applied Materials 0090-05777 REV 01 - AMAT DC DISTRIBUTION BOX
  • Advanced Energy 3155031-023A - AE 0190-01720 RF Match AMAT *used working
  • Applied Materials OEMNMCB3 - temperature controller
  • Applied Materials 0010-19706 - HEATER ASSY, 300MM ENDURA DEGAS, AMAT
  • Applied Materials 0010-29083 - POWER SUPPLY AMAT
  • Applied Materials 0015-09091 - AMAT PHASE ANGLE CON, P1038
  • Applied Materials 0010-30135 - DPS METAL THROTTLE VALVE AMAT
  • Applied Materials 0040-64389 - ENDURA II TXZ 300MM ISAC TOWER AMAT CDN396R CDN391R
  • Applied Materials 0190-01720 - (ADVANCED ENERGY 3155031-023) E-CHUCK POWER SUPPLY ASSY
  • RFPP RF-50SWC - 5000w 13.56MHZ Advanced Power AE Amat RF
  • Applied Materials 0190-05111 rev 002 - AMAT Control Video Switch