System Overview: Flexible I/O Platform Inside the Control Cabinet
Phoenix Contact's Inline I/O system is a modular I/O solution designed specifically for control cabinets. Its core features are a vast library of I/O and functional terminals, as well as openness to all mainstream fieldbus and Ethernet networks. As a long-term field validated I/O system, Inline is renowned for its reliability, ease of operation, and unparalleled flexibility.
The Inline system adopts a truly modular design: input/output terminals, communication terminals, and functional terminals can be expanded according to requirements, always meeting application requirements. The highly modular 12.5mm width module allows for minimal space expansion of the site - I/O in safety applications or intrinsically safe explosion-proof areas can also be easily accessed and integrated.
Panoramic view of functional terminal types
Inline supports flexible and application-oriented combinations of digital and analog I/O channels, covering the most commonly used standard functions:
Digital inputs
Digital outputs
Analog inputs
Analog outputs
Temperature recording
Counters
Pulse encoders
Position detection
Energy data acquisition
Communication
System characteristics and engineering details
3.1 Wiring and Replacement Advantages
The practical advantage of Inline lies in the details: the bus and power supply do not need to be separately wired - they are automatically connected when the expansion module is inserted. COMBICON spring cage wiring technology ensures fast I/O wiring; Due to the separation of the wiring layer and electronic layer, module replacement can be quickly and easily completed without the need for rewiring.
Other practical features include:
Integrated shielding connection: directly complete shielding connection on the terminal, saving control cabinet space;
Status and Diagnostic LEDs: There are indicator lights on each local bus terminal, clearly indicating the operating status of the Inline station. There are diagnostic LEDs on both the network and local bus;
Clearly numbered wiring terminals: simplified wiring by color coding of terminal points;
Optional plug coding: to prevent accidental insertion of the plug;
MARKING system: Terminals, wires, cables, and equipment can be quickly identified (IB IL Field 2/Field 8 identification fields, ESL 62X10/X46 laser printed identification plates, ZBFM 6 Zack identification strips, etc.);
Flexible Connection: Regardless of single wire, two-wire, three wire, or four wire technology, as well as any preferred sensor/actuator wiring technology, Inline can provide an ideal solution;
Selective segmentation: enhances system security through site segmentation with independent protection and separate switches.
3.2 Inline Block IO - Low Cost Compact Solution
Inline Block IO is a space saving extension of modular Inline I/O systems: the compact and flat Block IO integrates a fixed number of I/Os into the network. Especially for small I/O scenarios, the integration of I/O modules and bus couplers yields significant benefits in terms of operational convenience and cost.
Bus Openness: System Independent Integration
Thanks to the freely selectable bus coupler, the Inline system can connect to all mainstream fieldbus and Ethernet networks: INTERBUS、PROFIBUS、PROFINET、EtherNet/IP、DeviceNet、Modbus(TCP/RTU)、sercos、CANopen。 The communication terminal can integrate additional communication systems as subsystems into the Inline site.
Communication master terminals can connect various subsystems under the Inline site without the need for additional bus couplers: PROFIBUS master (DP V0 master/slave, maximum 12 Mbps), CAN master (CAN 2.0A/2.0B, 10 kbps – 1 Mbps), IO Link master (4 channels+12 digital inputs), AS-i master (specification 2.1, universally compatible with all couplers), IF system bus master (up to 8 EMM/EEM modules integrated, 31 measurement values and 16 control variables).
For centralized or distributed control tasks, the bus coupler can be directly replaced with a compact Inline controller. All controllers are parameterized and programmed using PC WORX engineering software based on IEC 61131, and PC WORX EXPRESS is a free simplified version suitable for compact controller programming.
Controller lineage
Class 100 high-performance controller (ILC 131/151/171/191 ETH, ILC 151 GSM/GPRS): Processing speed of 1.3-1.7 ms/K instructions, program/data storage of 192kB-1 MB, ILC 151 GSM/GPRS integrated modem.
Class 300 high-performance controller (ILC 330/350/370/390 PN series and ILC 370 PN 2TX-IB/M class certified version): processing speed as low as 0.2-0.7 ms/K instructions, program storage of 750 kB-2 MB, data storage of 1.5-4 MB, dual PROFINET interfaces (10/100)+built-in switch, flexible connection to higher-level control rooms, local operation stations or I/O modules; Some models come with an INTERBUS slave interface.
Machine Edition (ME) Compact Controller: ILC 191 ME/INC and ME/AN provide a processing speed of 1.3 ms/K instructions, 2 Ethernet ports, RS-485/RS-422 interface, dual channel pulse/direction interface and PWM, 8 event task compatible digital inputs, encoder input and fast counter input (up to 200 kHz).
Extreme Conditions (XC) version: The controller, bus couplers (Modbus TCP, INTERBUS), communication master station, and complete set of I/O terminals all offer an extended temperature range model from -40 ° C to+60 ° C, suitable for harsh environments.

Local bus expansion and long-distance transmission
5.1 Cabinet Expansion
Using a local bus extension terminal (such as IB IL 24 LSKIP-PAC), the Inline station can be extended by one or more rows in the control cabinet, up to a maximum of 20 meters.
5.2 Expansion to the Site
Through the Inline branch terminal (IB IL 24 FLM-PAC/FLM MULTI-PAC), Fieldline Modular devices with IP65/IP67 protection levels can be connected to the Inline local bus - without the need for additional bus couplers, directly connected to existing sites, saving time and effort. The maximum length of the M8/M12 local bus is 40 meters, with a maximum of 16 devices; FLM-PAC supports connection at the end of the site, while FLM MULTI-PAC supports access to the M8 local bus at any point of the site.
5.3 Point to point multiplex transmission
The Inline field multiplexer (IB IL 24 MUX MA-PAC) transmits industrial signals in pairs in a point-to-point manner - it can be transmitted through two-wire copper cables, fiber optics, modems, or wireless transmission. The digital and analog Inline I/O terminals can be freely combined without any software. Multiplexing mode transmission distance:
Second line copper cable: maximum 12 km;
Permanent telephone line: up to 20 km (requires converter);
Fiber optic: up to 45 km (requires converter).
A single set of MUX system can connect up to 512 digital or 32 analog I/O (or mixed) and transmit up to 512 I/O data.
5.4 Bluetooth wireless I/O
Industrial Bluetooth technology is used for I/O communication of Inline Block IO devices: it is easy to install and reliable for transmission, making it an ideal solution for input/output layer data transmission. ILB BT ADIO MUX-OMNI (omnidirectional antenna, 16 dBm) and MUX-PANEL (directional antenna, 12 dBm) both provide 16 digital inputs/16 digital outputs/2 analog inputs/2 analog outputs; ILB BT ADIO 2/2/16/16 is a wireless I/O device that can be accessed through FL BT MOD IO AP or FLM BT BS 3.
Functional Safety: SafetyBridge Technology
SafetyBridge I/O can achieve functional safety independently of the network at the Inline I/O layer. SafetyBridge technology performs all safety related functions in machines/systems - regardless of the type of Inline bus coupler used, SafetyBridge I/O modules can operate without the need for an additional safety controller and are certified for all mainstream Ethernet networks.
The advantage of network independence: SafetyBridge technology can be easily integrated into all mainstream fieldbus and Ethernet networks, continuing to use your preferred network solution without the need to build additional secure networks, saving time and cost for machine and system design.
Three key points of SafetyBridge
Centralized or distributed installation: The usage of flexible I/O modules is up to you to decide;
No need for a safety controller: The I/O integrated with SafetyBridge technology handles all safety functions, while the standard control system is only responsible for data exchange between I/O modules;
SAFECONF software easy configuration: After completing the security configuration, the generated security logic is downloaded to the security logic module through the standard control system.
Safety terminal specifications
Safety logic module (IB IL 24 LPSDO 8 V2/V3-PAC): V2 can connect 5 safety I/O modules (24 kB logical memory), V3 can connect 16 (60 kB logical memory); 4 secure dual channel or 8 secure single channel outputs per module, 24 V DC 2 A/channel; Intelligent logic module with 8 safety outputs, capable of connecting up to 16 additional safety I/O modules;
Secure Input Module (IB IL 24 PSDI 8/16-PAC): Each module has 4 secure dual channel or 8 secure single channel inputs, and 2 clock outputs powered by UT1/UT2; PSDI 16 is compatible with PROFIsafe and SafetyBridge;
Safety output module (IB IL 24 PSDO 8-PAC, PSDOR 4-PAC, PSDO 4/4-PAC): PSDOR 4 consists of 2 safety dual channel relays or 4 safety single channel relays (2 normally open contacts each), with 2 read back inputs for recording external circuit breakers; PSDO 4/4 is a digital output with 4 safety positive switches and 4 safety negative switches;
Safety level: All meet PL e (EN ISO 13849-1), SIL 3 (IEC 61508), and SIL CL 3 (EN IEC 62061) - these are key capabilities in high safety requirements areas such as the automotive industry, such as safety networks in automotive assembly.
In addition, the PROFIBUS coupler IL PB BK DI8 DO4/EF-PAC supports PROFIsafe; Both INTERBUS Safety and PROFIsafe safety I/O have corresponding product lines.
Intrinsic safety Ex-i: Intrinsic safety I/O in explosion-proof areas
Inline intrinsic safety I/O connects input and output signals to a network or bus system. Standard I/O terminals can be used in potentially explosive and non explosive areas up to Zone 2; The input/output signals of Zone 1 and Zone 0 can be connected through the blue I/O module - simply install the module at the Inline station. The terminals are parameterized using FDT technology and troubleshooting is carried out through channel level diagnosis.
I/O operation and installation partition reference in Ex environment (annual exposure time): Zone 2 (0.0-0.1%/year, maximum 10 hours), Zone 1/21 (0.1-10%/year, 10-1000 hours), Zone 0/20 (>10%/year, over 1000 hours).
Core intrinsic safety terminal
Intrinsic safety power terminal (IB IL EX-IS PWR IN-PAC): 24 V DC (UEx), maximum 1000 mA, diagnostic LED, electronic overload protection, very energy-efficient;
Ex-i Digital I/O (IB IL EX-IS DIO 4/NAM-PAC): 4-channel configurable, 2-wire connection, supports NAMUR sensor (EN 60947-5-6) and mechanical contact input, intrinsic safety solenoid valve/sound and light alarm/signal light output, single channel diagnosis, 8.2V sensor power supply;
Ex-i Analog I/O (IB IL EX-IS AIO 4/EF-PAC): 4-channel configurable, input 0-10 V/0-20 mA/4-20 mA, output 0-20 mA/4-20 mA, optional passive output, module level electrical isolation, single channel diagnostics;
Ex-i temperature input (IB IL EX-IS TEMP4 RTD/TC-PAC): RTD input Pt/Ni (DIN 100/200/500/1000), TC input J/K/E/R/S/T type, 4-wire connection, high precision.

Configuration and Engineering Software
8.1 Project+and CLIP Project
Using Project+and CLIP Project allows for quick and easy planning and configuration of I/O sites. The created site is based on actual needs, and after comparing and considering technical data and specifications, an efficient and error free site structure is ultimately obtained. Phoenix Contact provides a complete suite: planning, configuration, parameterized support for startup, and application programming integration (such as Siemens STEP 7/TIA Portal).
Project+: Quickly complete configuration without receiving training on configuration rules; By comparing all specifications, ensure optimal coordination of modules and eliminate errors such as selecting the wrong module; It can be downloaded for free from the official website;
CLIP PROJECT: After transferring the Project+planned Inline site, it is convenient to complete the configuration of the entire DIN rail; Form a consistent and efficient process chain through optimal interaction with CAE systems; CLIP PROJECT Marking can quickly generate site identifiers;
FDT technology: allows the Inline module to be parameterized independently of the controller, and the specialized device DTM provides a customized parameterization window; Function block libraries assist in fast startup and error free parameterization of I/O components;
The device description files for each relevant communication system can be downloaded, making it convenient to integrate Inline station signals into the controller.
Industry application examples
The Inline system is suitable for a wide range of industry solutions - whether you are deeply involved in the automotive industry, specialized in mechanical manufacturing, planning water and sewage treatment plants, or implementing logistics center automation, Inline can provide terminals that match specific application areas. The system is flexible and future oriented, ensuring investment costs even if future modifications are needed
Intelligent communication: In warehousing, logistics, and transportation technology, automation tasks are efficiently executed through various communication terminals (such as universal serial communication terminals, Inline IO Link master stations, etc.);
Optimal Collection: In water and wastewater treatment applications, the Inline power measurement terminal can achieve optimal collection of specific measurement values;
Secure Network: The automotive industry has extremely high requirements for system security, with Inline secure input/output terminals meeting PL e, SIL 3, and SIL CL 3 levels;
High cost-effective automation: The Inline ME version is particularly suitable for space saving and low-cost applications in machine batch production.
Certification and Reliability
The Inline system has numerous industry-specific and country specific certifications to ensure compliance with the specific requirements of your industry, with new certifications continuously increasing including INTERBUS, T Ü V Rheinland, PTB, UL/CSA, cULus, Ex Explosion proof, DNV, Lloyd's Register, Germanischer Lloyd, RINA, ABS (Classification), ODVA (DeviceNet/EtherNet/IP), PI (PROFIBUS/PROFINET), and more.
Product Overview Quick Look (Selection Points)
Bus coupler (Ethernet)
Model (Order Number) Bus I/O Configuration Width
IL PN BK DI8 DO4 2TX-PAC(2703994) PROFINET(stack 2.2) 8 DI / 4 DO 500 mA,RJ45 80 mm
IL PN BK DI8 DO4 2SCRJ-PAC (2878379) PROFINET (stack 3.1) as above, SCRJ45 80 mm
ILB PN 24 DI16 DIO16-2TX(2878146) PROFINET Block IO 16 DI + 16 DIO 500 mA, 3-port switch 156 mm
IL EIP BK DI8 DO4 2TX-PAC(2897758) EtherNet/IP V1.2 8 DI / 4 DO 80 mm
IL ETH BK DI8 DO4 2TX-PAC(2703981) Modbus TCP (UDP) 8 DI / 4 DO,HTTP/TFTP/BootP/SNMP 80 mm
ILB ETH 24 DI16 DIO16-2TX(2832962) Modbus TCP Block IO 16 DI + 16 DIO 156 mm
IL S3 BK DI8 DO4 2TX-PAC(2692380) sercos V1.1.2 8 DI / 4 DO 80 mm
Sercos site can also be expanded: ILB S3 24 DI8 DO4 AO2 INC-IN2 is a 2-axis positioning controller (± 10 V analog output, incremental encoder input, 8 DI, 4 DO); The ILB S3 AI4 AO2-2TX provides 4 inputs/2 outputs, 16 bit general-purpose analog signals (including Pt100/500/1000).
Bus coupler (fieldbus)
Model (order number) bus characteristics
IBS IL 24 BK-T/U-PAC (2861580) INTERBUS supports branch bus terminals, Inline plug bus connection, 48.8 mm
IBS IL 24 BK-LK/45-PAC (2862165) INTERBUS fiber optic connection 45 ° outgoing line, 85 mm
IBS IL 24 BK RB-LK-PAC (2861506) INTERBUS with remote bus branch, fiber optic
IL PB BK DI8 DO4/EF-PAC (2692322) PROFIBUS DP/V1, PROFIsafe compatible, IO Link calls, EF output
IL PB BK DP/V1-PAC(2862246) PROFIBUS DP/V1 2 A @ UL,D-SUB
IL DN BK DI8 DO4-PAC (2897211) DeviceNet TWIN-COMBICON connection, including CLIPFIX 35 end gear
IL CAN BK-TC-PAC(2718701) CANopen 2 A @ UL
IL MOD BK DI8 DO4-PAC(2878696) Modbus RTU (ASCII) D-SUB,80 mm
The corresponding Block IO (ILB) version covers combinations such as DI16/DI32/DO16/DO32/DI8 DO8/DI16 DO16/AI4 AO2, with 2/3 line connections and bus connections through Inline plugs or D-SUB/TWIN-COMBICON.
Power supply and segmented terminals
Power terminals (12.2 mm): IB IL 24 PWR IN-PAC (8 A), PWR IN/2-F (with fuse 6 A), PWR IN/2-F-D (with fuse+diagnostic 4 A); IB IL 120/230 PWR IN series (120/230 V AC, including isolation terminals, 36.6 mm);
Potential distribution terminals: IB IL PD 24V-PAC (US → 8 contacts), IB IL 24 PD GND-PAC (GND → 8 contacts);
Boost terminal: IB IL 24 PWR IN/R-PAC is used to boost the communication power supply and I/O voltage (logic maximum 2 A, 8 A @ UM/US, 48.8 mm); PWR IN/R/L-0.8A-PAC is specifically designed for communication power supply;
Segmented terminals: IB IL 24 SEG (8 A), SEG/F (fuse 6 A), SEG/F-D (fuse+diagnostic), SEG-ELF (electronic fuse+diagnostic 2.5 A) - the hardware foundation for implementing selective segmented protection.
Digital I/O terminals (12.2mm basic width, 48.8mm high-density version)
Digital input: 1 channel 120/230 V AC; 2-channel NPN; 4 channels; 8-channel single/4-wire (IB IL 24 DI 8/T2-PAC compliant with EN 61131-2 Type 2); 16/32 channel HD version (single wire connection);
Digital output: 1 channel 12-253 V AC 500 mA; 2-channel 24 V DC 2 A/NPN/EDO (parameterized output behavior); 4/8 channel 500 mA single or 4-wire, 8-channel 2 A, 8-channel NPN 1 A; 16/32 channel version;
Relay terminals: IB IL 24/230 DOR1/W (lamp load 3 A), DOR1/W-PC (inductive and capacitive load 2.6 A), DOR2/W (2 x SPDT, 5-50 V AC/5-120 V DC 2 A), DOR4 series (4 x SPDT), DOR4/HC-PAC (4 contacts 5-253 V AC maximum 10 A, high turn-on current); DOR LV-SET provides isolation terminals for relay output terminals.
Analog quantity and temperature terminal
Analog inputs: AI 2/SF (2-channel 16 bit universal), AI 2-HART (2-channel isolated, supporting HART sensors), AI 4/U (differential voltage 12 bit), AI 4/I (differential current 13 bit), AI 4/EF (with actuator power supply, overload protection, bus synchronization ≥ 1 ms, 16 bit), AI 8/SF and AI 8/IS (8-channel, including 0-25 V/± 25 V/0-50 V, 0-40 mA/± 40 mA range, multiplexing mode);
Analog outputs: AO 1/SF and AO 2/SF (16 bit, 500 Ω load, short circuit protection), AO 2/U/BP (± 10 V 16 bit), AO 2/UI (12 bit short circuit protection), AO 4/8/U/BP (4 or 8 output, short circuit protection, defined fast turn off behavior);
Temperature terminals: IB IL 24 TC (motor PTC thermistor evaluation, 1 input 1 output), TEMP2 RTD (2-channel 16 bit), TEMP2 UTH (2-channel thermocouple), TEMP4/8 RTD (2/3-wire or 4-wire connection, high-precision version with 4-wire connection).
Measurement and open-loop control terminals
Strain gauge measurement: IB IL SGI 2/F (extremely fast ≥ 1 ms, bus synchronization), SGI 2/P (high precision, RS-485 external display), SGI 1/CAL (can be calibrated by EC type approval, up to 3000 spacing values, matched with SGI EU CALSET calibration kit);
Power measurement: IB IL PM 3P/N/EF (3-phase+neutral wire, direct current acquisition of 1 A or 5 A, maximum outer conductor voltage of 690 V AC L-L);
Power level terminals: IB IL 400 MLR 1-8A (electromechanical load relay direct starter, 3.7 kW/400 V AC), ELR 1-3A (electronic load relay direct starter 1.5 kW), ELR R-3A (electronic reversible starter);
Positioning/Counting/PWM: IB IL SSI (single axis point-to-point absolute value SSI positioning, fast/slow motion principle), SSI-IN (SSI absolute value position reading, maximum 25 bit resolution), CNT (counter, 100 kHz, 24 bit binary counting, pulse generator), DI 8/S0 (8-channel S0 pulse encoder counter, 32-bit counting range), INC-IN (incremental encoder position, 25 bit actual value), IMPULSE-IN (magnetostrictive length measurement system position reading, 5 μ m position resolution), PWM/2 (2-channel PWM, pulse/direction interface control stepper motor power stage, maximum 50 kHz @ 5 V/500 Hz @ 24 V).
Communication terminal
Serial interface: IB IL RS UNI (configurable RS-232 or RS-485/422, process data only, 250 kbaud), RS 232/RS 232-PRO (38.4 kbaud), RS 485/422 and RS 485/422-PRO;
Special protocol: IB IL DALI/PWR (single channel DALI master station+integrated DALI power supply, safe electrical isolation, 61mm) and DALI/PAC extension terminals; IB IL MBUS (single channel M-bus master station, up to 30 M-bus devices, 19.2 kbaud); SRC-RS485 EVC EnOcean wireless receiver is used in conjunction with RS 485/422-PRO;
Local bus extensions: IBS IL 24 RB-T (INTERBUS remote bus branch, copper cable), RB-LK (fiber optic), FLM/FLM MULTI (Fieldline branch terminal), LSKIP (local bus extension terminal).
Accessory system
Improve the coverage of accessories throughout the entire process of the project:
VARIOFACE pre adapter (FLKM 14-PA-INLINE series): provides cabinet external adapter for 8/16/32 channel Inline modules;
Bus connectors: IBS DSUB 9/L and 9/C (D-SUB 9 connector), SUBCON 9/F-SH and 9/M-SH (INTERBUS D-SUB plug), SUBCON-PLUS-PROFIB/CAN (PROFIBUS and CAN plug), PSM-SET-FSMA/4-KT and 4-HCS (INTERBUS fiber FSMA plug);
End gears and end caps: CLIPFIX 35-5 standard end gear, CLIPFIX 35 (CANopen/DeviceNet coupler specific end gear), E/AL-NS 35 (vibration condition end gear), I-L ATP GN end cover plate, IL CP encoded profiles (100 pieces/pack).