RELIANCE ELECTRIC INVERTRON DBU dynamic braking unit: precise control of braking energy to ensure stable operation of the drive system

In industrial variable frequency drive systems, processes such as rapid deceleration of the motor, lowering of potential loads (such as lifting heavy objects from a crane), or stopping of a centrifuge will cause the motor to operate in a generating state, converting mechanical energy into electrical energy and feeding it back to the DC bus of the frequency converter. If this regenerated energy cannot be consumed in a timely manner, it will cause a sharp increase in DC bus voltage, threaten the safety of power devices, trigger overvoltage faults (such as the "HU" fault of GV3000), or force the frequency converter to automatically extend the deceleration time. The Dynamic Braking Unit (DBU) is a key component designed to address this issue. The INVERTRON DBU series guides excess DC bus energy to external braking resistors through intelligent control, safely dissipating it in the form of thermal energy to ensure the stability and reliability of the drive system during four quadrant operation. This article will comprehensively analyze the working principle, technical details, selection calculation, installation points, and advanced diagnostic functions of DBU.


The core function and working principle of DBU

A frequency converter with a diode rectifier bridge can only transmit energy unidirectionally on its DC bus, making the system essentially operate in two quadrants (forward and reverse electric). When the motor is in regenerative braking mode, energy cannot be fed back to the grid and can only accumulate in the DC bus capacitor, resulting in a voltage rise.

The core of DBU is an IGBT (Insulated Gate Bipolar Transistor) switching circuit controlled by an intelligent gate driver. It monitors the DC bus voltage (UDC) in real-time. When the UDC exceeds the preset "on" threshold (such as approximately DC 750V when set to 460V line voltage), the internal regulator of the DBU (initially a BUA type hysteresis regulator, later upgraded to a BUC type PWM regulator) will drive the IGBT to conduct at high frequency (BUC is 1kHz), connecting the DC bus to the external braking resistor. The braking resistor consumes energy, causing a decrease in UDC. When UDC is below the "turn off" threshold (such as DC 720V), IGBT turns off and stops consuming energy. Through this "switch" or "PWM" control, the DBU maintains the bus voltage within a safe range, allowing the inverter to quickly stop according to the set deceleration slope or stably control the potential load.

INVERTRON DBU offers four power levels and two configurations:

Basic models: DBU-50 (37kW), DBU-100 (75kW), DBU-200 (150kW)

Built in diagnostic card types: DBU-50-DIS, DBU-100-DIS, DBU-200-DIS

High power type (standard built-in diagnostic): DBU-400 (300kW)


Analysis of Key Specifications and Technical Parameters

Choosing and applying DBU requires a thorough understanding of its electrical and mechanical parameters.

Electrical specifications:

Maximum braking current (Imax): From 50A for DBU-50 to 400A for DBU-400, it defines the peak processing capability of the unit.

Minimum value of braking resistance: To ensure that the IGBT inside the DBU does not overcurrent, a resistor with a resistance value not less than the specified value must be used. The resistance value varies depending on the line voltage jumper setting (415V or 460V). For example, DBU-100 requires a resistance of ≥ 7.2 Ω at 460V.

Braking power:

Continuous braking power: The power that can be continuously consumed for a long time under a 460V bus voltage (such as 18kW for DBU-100).

Short term braking power: The peak power allowed to be processed in a short period of time (such as 75kW for DBU-100 at 460V). This corresponds to the power at which the maximum current Imax flows through the minimum allowable resistance.

Allowable load characteristics: To prevent thermal overload, the load of DBU during a 10 minute cycle must be limited within the current time area of "Imax x x 2.5 minutes". DBU-400 allows 400A current to last for 110 seconds/10 minutes.

Line voltage selection (key setting): The blue jumper plug (position: 460V/415V) on the regulator card under the DBU cover plate is crucial. It determines the operating voltage threshold of DBU.

Factory default: For safety reasons, set to 460V (corresponding to UDC activation point~750V).

415V system: Used for GV3000 frequency converters with line voltage ≤ 415V, or INVERTRON VTI/VCI/VGI 415V type (with a maximum allowable bus voltage of DC 720V), the jumper must be changed to 415V (corresponding to UDC turn-on point~680V).

The consequences of incorrect settings: Using 460V settings in a 415V system can cause the DBU to act too late, and the bus voltage may have triggered the inverter overvoltage fault before reaching 750V.

Environment and Machinery: Operating temperature range of 0-40 ° C (rated below 40 ° C), protection level IP20. During installation, it is necessary to ensure that the heat sink is vertical and there is at least 100mm space above and below for natural air convection (DBU-400 with fan, requires forced air cooling, air volume 158m ³/h).

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit