Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

SCHNEIDER TSX Premium System Operation and Maintenance

F: | Au:FANS | DA:2026-05-12 | 469 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Complete guide for on-site selection, installation, and troubleshooting of SCHNEIDER TSX Premium series (TSX P57-10/P57-20 processors and TSX DEY/DSY I/O modules)

In the field of industrial automation, Schneider Electric's Modicon TSX Premium platform has long served process control, infrastructure, and manufacturing industries with its high reliability, modular design, and powerful distributed processing capabilities. Among them, the TSX P57 series processors (P57-10 and P57-20) and the TSX DEY (input)/DSY (output) discrete I/O modules constitute the system core. Although Schneider has launched a new generation of controllers in recent years, a large number of existing production lines, water treatment stations, and packaging equipment are still running these classic modules. For on-site maintenance engineers, quickly mastering processor parameter configuration, I/O module characteristics, and identifying and troubleshooting common faults are key skills in reducing unplanned downtime. This article is based on the TSX Premium Quick Reference Guide (covering technical data in multiple language versions), which systematically outlines the practical knowledge of the entire process from processor selection, I/O module selection, installation and wiring, and fault diagnosis.


Detailed explanation of TSX P57-10 and TSX P57-20 processors

2.1 Capacity and scalability

The TSX Premium rack is connected via Bus X bus, and the processor is located in a specific slot of the rack (depending on the type of power module). The core difference between the two models lies in:

Characteristics TSX P57-10 TSX P57-20

Maximum number of racks (TSX RKY. E.) 2 x 8

The maximum number of I/O points is 512 discrete points, 24 analog signals are 1024 discrete points, and 80 analog signals are available

The maximum number of dedicated modules (counting, axis control, stepper, communication, weighing) is 2 and the maximum is 6

Internal RAM 32 kW 48 kW

PCMCIA memory expansion support (up to 96 Kwords) support (up to 176 Kwords)

1000 instruction execution time (RAM) 1.39 ms 0.78 ms

Programming software PL7 Junior (Windows) PL7 Junior (Windows)

Selection suggestion: If the on-site cabinet space is limited and the control scale does not exceed 512 points, P57-10 is economical and efficient; For production lines with multiple slave stations and high-speed processing requirements, P57-20 provides faster scanning cycles and larger application memory.

2.2 Built in interfaces and communication

The front panel of the processor provides:

TER port: 8-pin mini DIN (RS485 non isolated), default UNI-TELWAY master station, 19200 baud. It can be connected to programming terminals (such as FTX 117) or connected to UNI-TELWAY bus through TSX P ACC 01 isolation box. This port can output 5V power and is used for portable programmers.

AUX port: also an 8-pin mini DIN, used to connect to human-machine interface (HMI) or printer, but does not provide 5V power supply. Can be configured as UNI-TELWAY slave or ASCII character mode.

PCMCIA Type 3 communication card slot: Supports TSX SCP 111 (RS232 multi protocol), TSX SCP 112 (20mA current loop), TSX SCP 114 (RS485/422 isolation), and TSX FPP 10/20 (FIPIO Agent or FIPWAY). Important: Before plugging or unplugging the communication card, the processor power must be cut off, otherwise it may damage the card or cause system failure.

2.3 Memory backup and real-time clock

The internal RAM can be powered off and maintained through the optional battery (TSX PLP 01) on the power module. Please note: The battery is only effective when the processor and power module remain installed in the rack. Removing the processor will result in the loss of real-time clock and timestamp information. After shutdown, if the battery fails, the program and data will be lost. Therefore, it is recommended to replace the battery every 2-3 years.

2.4 RESET button and cold start

The pencil tip reset button on the front panel is used to force a cold start:

Press during normal operation: Depending on the configuration, it can be restarted to STOP or RUN state.

Fault status press: Force start in STOP mode. Attention: This operation will not clear the user program, but will reinitialize all data areas, which may cause production interruption and should be used with caution.


TSX DEY Discrete Input Module: Selection and Characteristics

The input module is used to connect on-site devices such as buttons, limit switches, proximity sensors, etc. According to the signal type and voltage level, it is mainly divided into two categories: DC input and AC input.

3.1 DC input module (24V/48V)

Model number, point connection method, rated voltage, input current (typical), filtering time in accordance with IEC 1131 type

TSX DEY 08D2 8-terminal block 24V DC 7mA 4ms Type 2

TSX DEY 16D2 16 terminal block 24V DC 7mA 4ms Type 2

TSX DEY 16D3 16 terminal block 48V DC 7mA 4ms Type 2

TSX DEY 16FK 16 HE10 connector 24V DC 3.5mA 0.1~7.5ms programmable Type 1

TSX DEY 32D2K 32 HE10 24V DC 3.5mA 4ms Type 1

TSX DEY 64D2K 64 HE10 24V DC 3.5mA 4ms Type 1

Key features:

Constant current input: 24V/48V DC input is a "current generation source" type. When the input voltage exceeds 11V (24V) or 20V (48V), the input current remains constant and is not affected by voltage fluctuations. This improves the tolerance to voltage drop in long cables.

  • Metso Valmet PEFT A413792 - Power Supply Module for Automation Systems
  • Valmet ABTU M2512201 - Analog Binary Termination Unit Module
  • Valmet ABMB MT036 PCB Card - Auxiliary Backplane Motherboard
  • Valmet A413345 FPUS Battery Backup Unit - Standby Power Module
  • Valmet A413060 DMU Rev 04 - Drive Monitor Unit Board
  • Valmet BOR82 A413292 - Binary Output Relay Module
  • Valmet A413383 Ver.04 ESW - Electronic Switching Module Board
  • Valmet Neles A415579 Valve Controller
  • Metso Valmet A413381 ESW Drive Board
  • Valmet ABTU Module 545266-2A 2-545264-2B - Analog Binary Termination Unit
  • Valmet ABMB MT838 PCB - Backplane Bus Mother Board
  • Valmet LEV-EL PG4 N1 H2S Sensor - 600mbar Gas Detector
  • Valmet ABMB MT940 PCB - Analogue Bus Mother Board Backplane
  • Valmet VAT65425921A MT241 PCB Board
  • Valmet A413310 VPU Power Unit - 230VAC 1.5A Automation Supply
  • Valmet Metso IOP303 Input Module 181504 - 32-Channel Digital Input
  • Valmet A413060 DMU Rev 07 - Data Management Unit
  • Valmet M851220 M1 PCB Card - Process Automation Interface Board
  • Valmet A413042 Ver.06 CPU
  • Valmet A413200-01 AIU 8 Analog Input Module
  • Basler DECS-250-CGCM-LN2SA1C Digital Excitation Control System
  • Valmet Automation PLC Module A413171
  • Valmet Automation 542852-3A Rack-Mount Cross Connect Panel
  • Valmet Marine Damatic M851565 Main Keyboard
  • Valmet TIU 6 Printed Circuit Board A413110
  • Metso Valmet U4440253V1.1 RMI CPU 300
  • Metso Valmet A413016 Ver.12 NCU2
  • Valmet M851565 Damatic Keyboard
  • Valmet ATB16-4 16 Channel Relay Card
  • Valmet Metso A413331 SPU Power Supply
  • Valmet PUD 10B Automation Control Rack
  • Valmet MT917 ABMB DMU PCB I/O Module
  • Valmet M851565 Damatic Keyboard Mkb2
  • Valmet EDS-518A-MM-SC Ethernet Gateway
  • Valmet 542836-6A PCB Card
  • Valmet ATB16-4/2 Terminal Board 9144047
  • Valmet ATB16-4 Controller Board 0-50°C 4-20mA Analog Output
  • Valmet 542852-3A Slot Rack Chassis Module
  • Valmet A413026 Ver.M1 FBC Board
  • Valmet IQ Basis Weight SH Sending Assembly A418081
  • Valmet PMB 2R Monolithic Backplane 8-Slot PCB 542821-5A and -5B
  • Valmet ATB16-4 16-Channel Relay Card Controller Board 22195028
  • Valmet Diff-EL SL6NK227SF0 Pressure Transmitter 0-380 mBar
  • Valmet A413110 TIU6 Board Ver.M1
  • Neles Automation A413278 Control Module
  • Valmet BCUTB Terminal Module 10101006 11091002
  • Valmet Senso 160 Measuring Station Display 160.2
  • Valmet AIU 1A Analog Input Unit M851245
  • Valmet IQ Web Caliper Sensor A420734
  • Valmet M851040/M8510401 Memory Board
  • Valmet AN35S1MC02RA Valve
  • Valmet M851121 M2 Cross Connect Panel
  • Valmet AIU-8 Simulator Board 421522-1A
  • Metso BIU 82 D200533 Binary Input Unit
  • Valmet M851121 M2 Module Rack
  • Valmet A413383 PC Board Module
  • Valmet N0542 NO54 ABMB PCB - 545200-3A Board
  • Valmet Metso IOP304 Input Module 181503
  • Valmet PDP601 Distributed Processing Unit 181585
  • Valmet A413084 CPU Board - Processor Module for Automation Systems
  • Valmet AIU 16T Analog Input Module M8512081 M1
  • Valmet AIU 16 Analog Input Module 545100-3A and 545100-3B
  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module