ABB BRC3000A Redundancy Cable
ABB BRC3000A Redundancy Cable
Main Functions
The main function of the ABB BRC3000A redundant cable is to provide backup support for the main cable. When the main cable fails, it can seamlessly switch to the backup cable to ensure the continuous and reliable operation of the industrial automation system.
Product Features
Durable & Abrasion Resistant:
The cable has excellent resistance to abrasion, corrosion and aging, and can be used for a long time in harsh environments to maintain system stability and reliability.
Waterproof and dustproof design:
The cable is designed to be waterproof, dustproof and corrosion-resistant, and is suitable for a variety of indoor and outdoor environments, ensuring that it can work properly under all kinds of harsh conditions.
Quick Installation:
The cable adopts quick-connect terminals, which simplifies the installation process and reduces installation time and cost.
Customisable:
According to the specific needs of customers, the cable can be customized in terms of length, specifications, colour, etc. to meet the needs of different application scenarios.
Technical specifications
Although specific technical specifications may vary depending on production batches and customisation requirements, ABB BRC3000A redundant cables usually have the following basic technical specifications:
Number of input channels: may contain multiple analogue input channels (e.g. 8).
Number of output channels: may contain multiple analogue output channels (e.g. 4).
Output voltage range: typically ±10VDC.
Input Impedance: Multiple impedance options may be available (e.g. 250Ω, 500Ω, 1200Ω, 2500Ω).
Accuracy: Typically high accuracy (e.g. ±0.10% F.S.).
Response Time: Short response time (e.g. 200ms).
Operating Temperature Range: Wide range of operating temperatures (e.g. -40°C to +70°C).
Operating humidity range: Adapt to higher operating humidity (e.g. 5% to 95% RH, non-condensing).
Application Scenarios
ABB BRC3000A redundant cable is widely used in various industrial automation systems, such as power monitoring systems, process control systems, robot control systems and so on. In these systems, it serves as one of the key components to ensure the stable operation of the system and the reliability of data transmission.
Precautions
Correct installation:
Please follow the installation guidelines in the product manual to ensure that the cable is correctly installed and connected to the corresponding equipment.
Regular Inspection:
Inspect the cable regularly to ensure that there are no signs of damage or aging.
Environmental Adaptation:
Before use, verify that the cable is suitable for your specific environment. Consult ABB's technical support team if required.
Parameter and signal display window
• Display and changing of parameters or signals in table form
• Each parameter or signal can be assigned to a parameter or signal group that can then be selected and processed as a group.
Regulator functions
• Voltage regulator with PID filter (AUTO operating mode)
• Field current regulator with PI filter (MAN operating mode)
• Reactive load and/or active load droop/compensation
• Limiters for:
– maximum and minimum field current
– maximum stator current (lead / lag)
– P/Q underexcitation
– Volts-per-Hertz characteristic
• Follow-up control – CHANNEL 1 ↔ CHANNEL 2 (for dual automatic channel systems)
– active CHANNEL ↔ BACKUP (for systems with backup regulator)
– operating mode AUTO ↔ MAN
• Power factor / reactive load regulation
• MANUAL restrict
• Power system stabilizer (option)
– conventional in accordance with IEEE - PSS2A
– Adaptive power system stabilizer
– Multiband power system stabilizer.