Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200STAOH2A Simplex Analog Output Terminal Board
    ❤ Add to collection
  • GE IS200STAOH2A Simplex Analog Output Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200STAOH2A Simplex Analog Output Terminal Board

    • ¥17000.00
      ¥17800.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 36)
Description

GE IS200STAOH2A Simplex Analog Output Terminal Board


GE IS200STAOH2A Simplex Analog Output Terminal Board

Part Number IS200STAOH2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200STAOH2A is a Simplex Analog Output Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in Distributed Control Systems. Compact analog output terminal boards are available, such as the Simplex Analog Output (STAO) terminal board, which is made for flat or DIN-rail mounting. Eight 0-20 mA analog outputs on STAO are powered by the PAOC I/O pack. Similar to the TBAO terminal board, the onboard circuitry and noise reduction are present. The board is equipped with high-density Euro-block style terminal blocks for connecting to the customers' devices. The board is identified to the I/O processor by an onboard ID chip for system diagnostics. 

The D-type connector is used to connect the I/O pack, which uses Ethernet to talk to the controller. INSTALLATION: The STAO and a plastic insulator are mounted in a panel or on a DIN-rail-mounted sheet metal carrier. The STAO plus insulator mount can also be attached to a sheet metal assembly that is bolted directly to a cabinet. Driven equipment can be placed up to 300 meters (984 feet) away from the turbine control cabinet and shouldn't have a resistance greater than 900. There are two varieties of Euro-block terminal blocks: An unpluggable mount terminal block with 36 terminals is present on STAOH1. A permanently installed terminal block with 36 terminals is present on STAOH2. The eight analog outputs are attached directly to the terminal block. For the SCOM connection, there are two screws. Typically, shielded twisted pair (#18 AWG) wires are utilized. An external mounting bracket supplied by GE or the client is used by the I/O cable shield termination. The mounting holes E1 and E2 are for the chassis ground screw connection (SCOM). To save cabinet space, DIN-type terminal boards can be stacked vertically on the DIN rail. 

 STAO Wiring and Cabling OPERATION: Eight analog control current outputs are supported by STAO. The voltage drop across the current sense resistor in the local loop is detected for each output, and the signal is transmitted back to the I/O processor that regulates the current. Each output's surge is suppressed and high-frequency noise is reduced by filters close to the signal exit point. The D/A converter and drivers that produce the regulated currents are found in the I/O processor. STAO Terminal Board DIAGNOSTICS: The output current is shown by the voltage drop across a series resistor on the board. A diagnostic alarm (fault) is generated by the I/O processor if either of the two outputs becomes unhealthy. The I/O controller queries each ID device that each cable connector on the terminal board has to offer. The terminal board serial number, board type, revision number, and the placement of the JR, JS, and JT connectors are all encoded on a read-only chip known as the ID device. A hardware incompatibility fault is produced when the I/O controller reads this chip and runs across a mismatch.

SPECIFICATIONS

Part No: IS200STAOH2A
Manufacturer: General Electric
Function: Terminal Board
Series: Mark VIe
Number of channels: 8
Analog output current: 0-20 mA
Customer load resistance: Up to 900 Ω
Size: 15.9 cm high x 10.2 cm wide
Operating temperature: -30 to 65oC
Technology: Surface mount
Availability: In Stock
Product of Origin: USA
Manual: GEH-6721

FUNCTIONAL DESCRIPTION:

IS200STAOH2A is a Simplex Analog Output Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in Distributed Control Systems. Compact analog output terminal boards are available, such as the Simplex Analog Output (STAO) terminal board, which is made for flat or DIN-rail mounting. Eight 0-20 mA analog outputs on STAO are powered by the PAOC I/O pack. Similar to the TBAO terminal board, the onboard circuitry and noise reduction are present. The board is equipped with high-density Euro-block style terminal blocks for connecting to the customers' devices. The board is identified to the I/O processor by an onboard ID chip for system diagnostics. The D-type connector is used to connect the I/O pack, which uses Ethernet to talk to the controller.

INSTALLATION:

The STAO and a plastic insulator are mounted in a panel or on a DIN-rail-mounted sheet metal carrier. The STAO plus insulator mount can also be attached to a sheet metal assembly that is bolted directly to a cabinet. Driven equipment can be placed up to 300 meters (984 feet) away from the turbine control cabinet and shouldn't have a resistance greater than 900. There are two varieties of Euro-block terminal blocks:

An unpluggable mount terminal block with 36 terminals is present on STAOH1.

A permanently installed terminal block with 36 terminals is present on STAOH2.

As seen in the following diagram, the eight analog outputs are attached directly to the terminal block. For the SCOM connection, there are two screws. Typically, shielded twisted pair (#18 AWG) wires are utilized. An external mounting bracket supplied by GE or the client is used by the I/O cable shield termination. The mounting holes E1 and E2 are for the chassis ground screw connection (SCOM). To save cabinet space, DIN-type terminal boards can be stacked vertically on the DIN rail.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide