  • GE IS200STAOH2A Simplex Analog Output Terminal Board
    ❤ Add to collection
  • GE IS200STAOH2A Simplex Analog Output Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200STAOH2A Simplex Analog Output Terminal Board

    • ¥17000.00
      ¥17800.00
      ¥17000.00
      ¥17000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 36)
Description

GE IS200STAOH2A Simplex Analog Output Terminal Board


GE IS200STAOH2A Simplex Analog Output Terminal Board

Part Number IS200STAOH2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200STAOH2A is a Simplex Analog Output Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in Distributed Control Systems. Compact analog output terminal boards are available, such as the Simplex Analog Output (STAO) terminal board, which is made for flat or DIN-rail mounting. Eight 0-20 mA analog outputs on STAO are powered by the PAOC I/O pack. Similar to the TBAO terminal board, the onboard circuitry and noise reduction are present. The board is equipped with high-density Euro-block style terminal blocks for connecting to the customers' devices. The board is identified to the I/O processor by an onboard ID chip for system diagnostics. 

The D-type connector is used to connect the I/O pack, which uses Ethernet to talk to the controller. INSTALLATION: The STAO and a plastic insulator are mounted in a panel or on a DIN-rail-mounted sheet metal carrier. The STAO plus insulator mount can also be attached to a sheet metal assembly that is bolted directly to a cabinet. Driven equipment can be placed up to 300 meters (984 feet) away from the turbine control cabinet and shouldn't have a resistance greater than 900. There are two varieties of Euro-block terminal blocks: An unpluggable mount terminal block with 36 terminals is present on STAOH1. A permanently installed terminal block with 36 terminals is present on STAOH2. The eight analog outputs are attached directly to the terminal block. For the SCOM connection, there are two screws. Typically, shielded twisted pair (#18 AWG) wires are utilized. An external mounting bracket supplied by GE or the client is used by the I/O cable shield termination. The mounting holes E1 and E2 are for the chassis ground screw connection (SCOM). To save cabinet space, DIN-type terminal boards can be stacked vertically on the DIN rail. 

 STAO Wiring and Cabling OPERATION: Eight analog control current outputs are supported by STAO. The voltage drop across the current sense resistor in the local loop is detected for each output, and the signal is transmitted back to the I/O processor that regulates the current. Each output's surge is suppressed and high-frequency noise is reduced by filters close to the signal exit point. The D/A converter and drivers that produce the regulated currents are found in the I/O processor. STAO Terminal Board DIAGNOSTICS: The output current is shown by the voltage drop across a series resistor on the board. A diagnostic alarm (fault) is generated by the I/O processor if either of the two outputs becomes unhealthy. The I/O controller queries each ID device that each cable connector on the terminal board has to offer. The terminal board serial number, board type, revision number, and the placement of the JR, JS, and JT connectors are all encoded on a read-only chip known as the ID device. A hardware incompatibility fault is produced when the I/O controller reads this chip and runs across a mismatch.

SPECIFICATIONS

Part No: IS200STAOH2A
Manufacturer: General Electric
Function: Terminal Board
Series: Mark VIe
Number of channels: 8
Analog output current: 0-20 mA
Customer load resistance: Up to 900 Ω
Size: 15.9 cm high x 10.2 cm wide
Operating temperature: -30 to 65oC
Technology: Surface mount
Availability: In Stock
Product of Origin: USA
Manual: GEH-6721

FUNCTIONAL DESCRIPTION:

IS200STAOH2A is a Simplex Analog Output Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in Distributed Control Systems. Compact analog output terminal boards are available, such as the Simplex Analog Output (STAO) terminal board, which is made for flat or DIN-rail mounting. Eight 0-20 mA analog outputs on STAO are powered by the PAOC I/O pack. Similar to the TBAO terminal board, the onboard circuitry and noise reduction are present. The board is equipped with high-density Euro-block style terminal blocks for connecting to the customers' devices. The board is identified to the I/O processor by an onboard ID chip for system diagnostics. The D-type connector is used to connect the I/O pack, which uses Ethernet to talk to the controller.

INSTALLATION:

The STAO and a plastic insulator are mounted in a panel or on a DIN-rail-mounted sheet metal carrier. The STAO plus insulator mount can also be attached to a sheet metal assembly that is bolted directly to a cabinet. Driven equipment can be placed up to 300 meters (984 feet) away from the turbine control cabinet and shouldn't have a resistance greater than 900. There are two varieties of Euro-block terminal blocks:

An unpluggable mount terminal block with 36 terminals is present on STAOH1.

A permanently installed terminal block with 36 terminals is present on STAOH2.

As seen in the following diagram, the eight analog outputs are attached directly to the terminal block. For the SCOM connection, there are two screws. Typically, shielded twisted pair (#18 AWG) wires are utilized. An external mounting bracket supplied by GE or the client is used by the I/O cable shield termination. The mounting holes E1 and E2 are for the chassis ground screw connection (SCOM). To save cabinet space, DIN-type terminal boards can be stacked vertically on the DIN rail.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice