  • GJR5253200R1161 MODBUS Communication Processor
    ❤ Add to collection
  • GJR5253200R1161 MODBUS Communication Processor

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    MODBUS Communication Processor
    Manufacturers
    ABB

    Model(s)
    ABB Advant Controller 31, ABB Advant OCS

    Additional Information
    07KP93B Module, MODBUS protocol, 2 communication channels,Master and Slave operation, operation Interfaces RS232/422/485, Supply Voltage 24 Vdc
    Estimated Shipping Size
      Dimensions: 6.0" x 4.0" x 6.0"
      (15.2 cm x 10.2 cm x 15.2 cm)
      Weight: 0 lbs 15.0 oz (0.4kg )


    Tariff Code: 8517620050


    Country of Origin: Sweden
      Ships from Webster NY, USA

    • ¥510.00
      ¥122930.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.000KG
    • Quantity:
    • (Inventory: 2)
Description
MODBUS Communication Processor
Manufacturers
ABB

Model(s)
ABB Advant Controller 31, ABB Advant OCS

Additional Information
07KP93B Module, MODBUS protocol, 2 communication channels,Master and Slave operation, operation Interfaces RS232/422/485, Supply Voltage 24 Vdc
Estimated Shipping Size
  Dimensions: 6.0" x 4.0" x 6.0"
  (15.2 cm x 10.2 cm x 15.2 cm)
  Weight: 0 lbs 15.0 oz (0.4kg )


Tariff Code: 8517620050


Country of Origin: Sweden
  Ships from Webster NY, USA


GJR5253200R1161 MODBUS Communication Processor

Basic information

Model number: The complete model number is GJR5253200R1161 07KP93, where GJR5253200R1161 is the specific number of the product and 07KP93 is the series or function code to which it belongs, etc., which is used to accurately identify the product in the ABB product system.

Place of origin: Sweden.

Functional features

Communication interface and protocol support: Equipped with two communication channels, it supports RS232/422/485 interface, and can be flexibly connected with various devices. Meanwhile, it fully supports the RTU mode of MODBUS protocol, which can transmit more data under the same baud rate and improve the communication efficiency, which is suitable for the interaction of large amounts of data in the industrial environment.

Master-slave operation mode: It has two operation modes: master and slave, which can be flexibly configured according to the actual application requirements. As a master, it can initiate communication requests and perform data query and control on slave devices; as a slave, it can respond to the master's requests and accurately return data or perform corresponding operations to the master, thus realising efficient coordination and data sharing among devices.

Data processing and transmission: the core function is to process and transmit MODBUS communication data. It can receive MODBUS data from external devices and process the data according to the protocol such as parsing and checking to ensure the accuracy and integrity of the data. Then the processed data will be transmitted to the control system or other devices connected to it, and at the same time, it can also convert the commands and data issued by the control system into MODBUS format and send them to the corresponding external devices, realising two-way data communication.

Technical Parameters

Working voltage: the working power supply is 24V DC, which matches the common DC power supply voltage level in industrial automation control system, and it is convenient to share the power supply with other devices, which reduces the complexity and cost of the system.

Application Fields

Industrial automation control system: widely used in various industrial automation production lines, such as automotive manufacturing, food and beverage processing, electronic equipment production and other industries. It can be used to connect PLCs, sensors, actuators and other devices in the production line, to achieve coordinated control and data sharing between the devices, and to improve production efficiency and product quality.

Process control system: In chemical, petroleum, natural gas and other process industries, it is used to connect the on-site smart meters, controllers and remote monitoring systems. Through the communication processor, the temperature, pressure, flow and other process parameters collected by the field equipment can be transmitted to the monitoring centre in real time, and at the same time, the control instructions can also be accurately sent to the field equipment to ensure the safe and stable operation of the production process.

Intelligent building and energy management system: In the field of intelligent building, it can be used to connect various equipments in the building, such as air-conditioning system, lighting system, lift system, etc., to realise remote monitoring and intelligent management of the equipments. In addition, in the energy management system, it can communicate with energy measuring instruments, smart meters and other equipment to achieve real-time monitoring of energy consumption and data analysis, providing support for energy saving and consumption reduction.

OTHER INFORMATION

• Read the safety precautions carefully. 

• Check the delivery for transportation damage. If damage is found, notify the  supplier as soon as possible. 

• Do not use the operator panel in an environment with high explosive hazards. 

• The supplier is not responsible for modified, altered or reconstructed  equipment. 

• Use only parts and accessories manufactured according to specifications of the  supplier. 

• Read the installation and operating instructions carefully before installing,  using or repairing the operator panel. 

• Never allow fluids, metal filings or wiring debris to enter any openings in the  operator panel. This may cause fire or electrical shock. 

• Only qualified personnel may operate the operator panel. 

• Storing the operator panel where the temperature is lower/higher than  recommended in this manual can cause the LCD display liquid to  congeal/become isotopic. 

• The LCD display liquid contains a powerful irritant. In case of skin contact,  wash immediately with plenty of water. In case of eye contact, hold the eye  open, flush with plenty of water and get medical attention.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer