Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200TBQAG1A Terminal Board
    ❤ Add to collection
  • GE DS200TBQAG1A Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200TBQAG1A Terminal Board

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

GE DS200TBQAG1A Terminal Board


GE DS200TBQAG1A Terminal Board

Part Number DS200TBQAG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TBQAG1A is a Thermocouple Termination Module manufactured and designed by General Electric as part of the Mark V LM Series used in gas turbine control systems. The R1 and R5 cores contain the TBQA (Thermocouple Termination Module). 45 thermocouple input signals can be received by the TBQA terminal board. The TBQA in R1 distributes its input signals in the following ways: 15 signals (thermocouples #1 through #15) go to the TCQA in R1, 15 signals (thermocouples #16 through #30) go to the TCQA in the core of R2, and 15 signals (thermocouples #31 through #45) go to the TCQA in R3. 42 thermocouple input signals are connected to the TCCA board in "R5" and can be received by the TBQA board in "R5". 

The circuits for compensating for cold junctions are likewise provided by the TBQA board. TBQA CONNECTIONS: JAR - Writes the cold junction signal and the thermocouple signals #1 through #15 to the TCQA board in the core. The thermocouple signals #1 through #15 and the cold junction signal are written to the TCCA board in the core from the core. JAS - Writes the cold junction signal and thermocouple signals #16 through #30 to the TCQA board in the core. The thermocouple signals #16 through #30 and the cold junction signal are written to the TCCA board in the core from the core. JAT - Thermocouple signals #31 through #45 and a cold junction signal are written to the TCQA board in the 'R3' core from the 'R1' core. The thermocouple signals #31 through #42 and the cold junction signal are written from the R5> core to the TCCA board in the R5> core. 

 THERMOCOUPLE INPUTS: Three groups of 15 people each make up the TBQA terminal board, one group for each core, and each group has its own solid-state cold junction compensation. Typically, control and trip purposes are handled by the thermocouple inputs. 42 thermocouples that are mounted on a TBQA terminal board inside the R5 core can be monitored by the R5 controller. Three groups of fourteen inputs each having a distinct solid-state cold junction correction make up this group of inputs. R5 inputs are usually solely used for monitoring; they are never utilized for control or trip.

This DS200TBQAG1A product offering is a Thermocouple Termination Module originally manufactured for placement in General Electric's Mark V Turbine Control System Series, as explained earlier. As you have surely been able to discern based on its full extended series name, the Mark V product series that this DS200TBQAG1A PCB belongs to has specific applications in the management and control systems of compatible steam, wind, and gas turbine automated drive assemblies, and is considered one of the final General Electric product series to make use of the company's patented Speedtronic control system technology. This DS200TBQAG1A PCB's Mark V Turbine Control System Series, while one of the final GE Speedtronic product series, is also considered a now-obsolete legacy series due to its eventual manufacturing discontinuation in the years following its initial release. This DS200TBQAG1A PCB, while functionally-describable as a Thermocouple Termination Module, is not the original product of its intended functionality to feature within the Mark V; that would be the DS200TBQAG1 parent printed circuit board missing this DS200TBQAG1A Board's A-rated functional product revision.

Hardware Tips and Specifications

This DS200TBQAG1A printed circuit board necessitates its own series of functionally-important hardware components and component specifications. The GE RST Terminal Board DS200TBQAG1A features 2 90-pin terminal blocks to support a maximum of 180 signal wires. The terminal blocks are labeled TB1 and TB2. The GE RST Terminal Board DS200TBQAG1A also contains 3 20-pin connectors. The GE RST Terminal Board DS200TBQAG1A contains five screw holes that secure the board inside the board rack. The board is heavy due to the terminal blocks and the multiple signal wires so it must be securely attached to the rack. As discussed in this DS200TBQAG1A product offering's originally-introduced instructional documentation, no hardware customization is possible in the assembly of this DS200TBQAG1A printed circuit board as no manually-moveable hardware jumpers have been inserted in its assembly; Berg-type or otherwise. Several different styles of Mark V Turbine Control System Series connectors have been made available to the assembly of this DS200TBQAG1A Thermocouple Termination Module. These connectors include:

The JAR TCQA Board Thermocouple Signals Connector

The JAS TCQA Board Thermocouple Signals Connector

The JAT TCQA Board Thermocouple Signals Connector


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide