Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200TCCAG2A  Analog I/O Board
    ❤ Add to collection
  • GE DS200TCCAG2A Analog I/O Board

    110V-380V
    1A-30A
    5W-130W
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200TCCAG2A  Analog I/O Board

    • ¥22000.00
      ¥24520.00
      ¥22000.00
      ¥22000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

GE DS200TCCAG2A  Analog I/O Board


GE DS200TCCAG2A  Analog I/O Board

Part Number DS200TCCAG2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCCAG2A is a Common Analog I/O Board developed by GE. It is a part of mark V series. The Common Analog I/O Board (TCCA), which is housed in the R5 core, scales and conditions analog signals from the CTBA, TBQA, and TBCA terminal boards. 4-20 mA inputs and outputs, RTD inputs, thermocouple inputs, shaft voltage inputs, and shaft current inputs are among the signals available. The STCA board receives the signals via the 3PL connector. 

 Connectors 2PL - Power distribution from the TCPS board in the R5 core. 3PL - The Data Bus in core R5 that connects the STCA, TCCA, and TCCB boards. Conditioned signals are transferred to the COREBUS via 3PL. JAA - Transports 420 mA output signals to the CTBA terminal board. JBB - Transports the CTBA terminal board's shaft voltage and current signals, as well as 4-20 mA input signals. JCC - RTD input signals from the TBCA terminal board are carried by JCC. 

JDD - RTD input signals from the TBCA terminal board are carried by this bus. JAR/S/T - Transports thermocouple and cold junction input signals from the TBQA terminal board. JC - Transports TCPS power supply diagnostic signals. JEE - Not Typically used. DS200TCCAG2A Configuration Hardware On the TCCA board, there are three hardware jumpers: J1, JP2, and JP3. J1 is used to enable and deactivate the serial RS232 port. JP2 is used to turn off the oscillator during card testing. JP3 is used in the factory for testing. Appendix A contains information on how to configure the hardware jumpers on this board.

 Software The I/O Configuration Editor on the HMI is used to enter I/O configuration constants for thermocouples, RTDs, mA inputs and outputs, and shaft voltage and current settings. Thermocouple Circuit The TBQA terminal board reads the thermocouple inputs. The cold junction circuitry on the TBQA terminal board generates the cold junction signals. The TCCA board uses these values to calculate cold junction compensation. The thermocouple input and compensation value are used by the TCCA board to calculate the actual temperature read by the thermocouple. The value is read by the I/O Engine via the 3PL connector. I/O configuration constants are used to select thermocouple types and curves.C) 

OTHER INFORMATION

As with any General Electric Mark V Series product, this DS200TCCAG2A Common Analog I/O Board was manufactured using multiple product-specific hardware components; contributing towards its intended functionality as a Common Analog I/O Board. Fortunately for our purposes, this DS200TCCAG2A Common Analog I/O Board can additionally be considered a well-documented General Electric product offering, as it is detailed in product-specific instructional manual materials.

Hardware Tips and Specifications

The GE I/O TC2000 Analog Board DS200TCCAG2A features one 80196 microprocessor and multiple PROM modules. It also contains one LED and 2 50-pin connectors. The LED is visible from the side view of the board. The IDs for the 50-pin connectors are JCC and JDD. The GE I/O TC2000 Analog Board DS200TCCAG2A also is populated with 5 34-pin connectors. Both the 50-pin and the 34-pin connectors use ribbon cables to connect to the rest of the DS200TCCAG2A board's assembly. Because of the potential for multiple 34-pin ribbon cables that could be connected to the new board, it is important to know where they connect when the new board is installed. Another consideration with the ribbon cables inherent to this DS200TCCAG2A Common Analog I/O Board is the proper handling technique when you disconnect them from the board. Ribbon cables have minimal support between the connector and the cable attached to them; with this in mind it is easy to pull the wires out of the connector if you tug the cable out of the connector on the board. To avoid that problem, only pull the cable out by holding the connector at the end of the ribbon cable, before gently pulling it out of the connector on the board. Adding to our ribbon cable problem here is that fact that the ribbon cable is comprised of multiple individual strands of copper wire; without taking the ribbon cable apart it is impossible to know if the connections are intact.

The ribbon cables and connectors adopted by this DS200TCCAG2A Common Analog I/O Board are not the only hardware elements present in its assembly. This DS200TCCAG2A Common Analog I/O Board additionally makes use of three total manually-moveable hardware jumpers; included in its assembly for different purposes. The JP1-labeled jumper present in this PCB's assembly is responsible for disabling of the RS-232 serial communications port. The JP2-labeled jumper present in the assembly of the DS200TCCAG2A I/O Board can disable this device's oscillator for card test. Finally, the JP3 jumper included with the DS200TCCAG2A Common Analog I/O Board is included for factory testing purposes only.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Meggitt Vibro Meter RPS 6U rack power module
  • Motorola MVME Series IPMC712/761 I/O Module
  • Analog Devices DS3800 Advanced NV SRAM Battery Cover
  • ABB DO02 digital output module
  • GE Multilin D20/D200 Substation Controller
  • ABB PBA800 Process Bus Adapter
  • Foxboro Evo FBM237 Analog Output Module
  • Foxboro Evo FBM217 Discrete Input Module
  • Allen Bradley 1756 ControlLogix I/O Specifications Module
  • ​Molex SST-ESR2-CLX-RLL and SST-SR4-CLX-RLL communication modules
  • How to install ABB ACS880-01-025A-3 frequency converter?
  • SEMIKRON SKiiP 1213 GB123-2DL V3 module
  • Bently 3500/60 and 3500/61 temperature modules
  • ABB ACS880-01-025A-3 frequency converter
  • Emerson DeltaV S-series Traditional I/O Modules
  • HONEYWELL EXCEL 5000 OPEN SYSTEM
  • Pepperl+Fuchs RSD-CI2-Ex8 Analog Input Module
  • Bently Nevada 3500/50M tachometer module
  • Woodward 2301A 9907 series electronic load distribution and speed controller
  • ABB IMDSI13 Digital Slave Input Module
  • Eaton XV-102 Touch Screen Display
  • Rockwell ProSoft MVI56-MCM Modbus master-slave communication module
  • Watlow Series CLS200 Controller
  • GE IS230 Series Industrial Managed Layer 2 Switches
  • GE IC693TCM302/303 Temperature Control Module
  • MKS 979B Atmosphere to Vacuum Transducer
  • What scenarios is the Syco Tec 4061 AC motor spindle suitable for?
  • Emerson DeltaV Electronic Marshalling Migration Solution
  • Barber Colman MA41-7153-502 and similar series actuators
  • BARTEC MODEX PROFIBUS 07-7331-2305 Series Interface Module
  • Rockwell Automation 1794 Series FLEX I/O Digital Input Module
  • GE PCI5565 Multi Channel MIL-STD-1553 Interface Card
  • How to install the Rockwell Automation 1757-SRM (B-series) module?
  • KIDDE S732DVT-EST1 Digital Video, 2-Way MPD Data Tx, MM, Can
  • Foxboro Evo ™ FBM217 Discrete Input Module
  • Allen-Bradley SLC 500 ™ 1746 series I/O modules
  • Allen-Bradley SLC 500 ™ Installation Guide for 32 Channel Digital I/O Module
  • Allen Bradley 1746-NI8 Analog Input Module Application Case
  • Rockwell 1746-IB32 Digital Input Module
  • Emerson PACSystems ™ Ethernet Switch SLM082
  • How to install GE IC695CRU320 redundant control unit?
  • Bently 3500/15 AC and DC power modules
  • Horner APG HE693CALKIT simulation module
  • ABB INNPM22 Network Processor Module
  • Eckardt SRI986 Intelligent Valve Positioner
  • Honeywell System 57 5704 Control System
  • Schneider Electric 140CHS 1100 Communication Module
  • Moog CD series compact dynamic brushless servo motor
  • HARTING DIN 41612 connector
  • ABB DAPU100 3ASC25H204 Interface Template
  • ProSoft Technology ILX56-PBM PROFIBUS DPV1 Master/Slave Module
  • Emerson DeltaV S Series Traditional I/O Modules
  • MOTOROLA MVME6100 series VME single board computer
  • Emerson MVME5100 Series VME Bus Processor Module
  • Siemens 6EP1334-3BA00 (SITOP PSU200M) stabilized power supply
  • GE Power Management SR489 Generator Management Relay
  • Eaton MTLx544-S Series (MTL4544/S, MTL5544/S) Relay Power Supply
  • Emerson MVME5100 Series VME Bus Processor Module
  • Teknic SSt-6000-U Digital Servo Drive
  • HIMA HIMatrix MI 24 01 Safety Related Controller Module (HI 800 209 E)
  • Horner Automation MAN0344-03 Industrial Controller/Human Machine Interface (HMI)
  • Emerson Automation Series MC-PHAI01 (51403479-150) 8-Channel Analog Input Module
  • Bently Nevada 3500/42M Proximity Seismic Monitor
  • GE VMIACC5595 Embedded Industrial Control Module
  • Rockwell SLC ™ 500 series 1747-L543 (SLC 5/04 controller)
  • Honeywell WEB-HMI10/CF 10.1 "TFT ARM Cortex-A53 Quad Core 3 Ethernet, 2 USB ports
  • How to install the Rockwell Automation 1756 series ControlNet communication module?
  • National Instruments 6030E/6031E/6032E/6033E series
  • ABB 1TGE120011R1000 motor and feeder control unit
  • Watlow CLS200 series controller
  • Schneider 140DDI84100 Discrete Input Module
  • How to install the Modicon Quantum 140ACI03000 analog input module?
  • Rockwell Automation ControlLogix 5570 and 5560 controllers
  • ABB IEMMU21 module installation unit (rear installation)
  • Endress+Hauser Prosonic T FMU30 Ultrasonic Liquid Level Measuring Instrument
  • ABB SC510 submodule carrier (without CPU)
  • Beijer Mitsubishi Electric E1000 Series Operation Panel
  • HIMA HIMatrix F30 Compact Safety Controller
  • HIMA HIMax Safety Control System
  • HIMA HIMatrix F2 DO 8 01 Remote I/O Module
  • HIMA HIQuad X Safety System
  • HIMA HIMax X-SB 01 System Bus Module
  • How to order KOLLMORGEN Saia PCD series I/O modules?
  • Kollmorgen S700 series digital servo amplifier
  • KOLLMORGEN P70360 High Performance Microstep Driver
  • KOLLMORGEN AKM series synchronous servo motor
  • KOLLMORGEN AKD ®- N servo drive
  • KOLLMORGEN AKD ® Servo driver CANopen communication
  • KOLLMORGEN AKD ® Servo drive fault card
  • SERVOSTAR ® CD series servo amplifier
  • SERVOSTAR ® Usage of CD-LITE servo amplifier
  • SERVOSTAR ™ 601... 620 digital servo amplifier (S600 series)
  • B&R Power Panel 300/400 Touch Screen
  • Emerson S-series Mass Connection Solutions
  • Emerson DeltaV SIS Logic Solver (SLS1508)
  • How to order Emerson DeltaV Ethernet I/O Card (EIOC)?
  • Emerson DeltaV ™ M-series Traditional I/O
  • Emerson DeltaV ™ Electronic Marshalling for Migrations
  • Emerson DeltaV Controller Redundancy Function
  • Emerson DeltaV Bulk Power Supplies
  • Emerson DeltaV SD Plus Controller
  • Emerson DeltaV M Series Virtual I/O Module 2 (VIM2)
  • Emerson DeltaV M Series MD Plus Controller
  • Emerson Ovation ™ Power system (5X00785G09)
  • Emerson DeltaV Intelligent Switch
  • Emerson A6110 Dual Channel Shaft Vibration Monitor
  • Emerson MMS 3210/xxx-xxx Dual Channel Shaft Position Transmitter for Eddy Current Sensors
  • Emerson MMS 3120 Dual Channel Bearing Vibration Transmitter
  • Emerson MMS 677X Dual Channel Bar Chart Indicator
  • Emerson Martens Standard Signal Instrument S 1010
  • Emerson CON021 Eddy Current Signal Converter Ordering Method!
  • How to order AMS 6500 Classic system protection card?
  • Emerson Machine Monitoring Systems RPM Transformer PR 9376
  • Emerson Linear Displacement Sensor PR 9350/.. Series
  • Emerson PR 9376 series eddy current sensor system
  • Emerson Electric Power Absolute Vibration Sensor (PR 9266/.. And PR 9268/..)
  • How to operate Emerson Motion Control FX 490?
  • Emerson The Ovation ™ What fields is the Control System applicable to?
  • Emerson Ovation Distributed Control System Input/Output (I/O) Module
  • Emerson HART High Performance Analog Input Module
  • Emerson Ovation ™ Controller Model OCR1100
  • Emerson PAC8000 Remote I/O
  • Emerson A6500-LC LVDT preamplifier
  • EMERSON A6370 Overspeed Protection Monitor
  • EMERSON A6110 axis relative vibration monitor
  • EMERSON FloBoss ™ S600+ Flow Computer
  • EMERSON CSI 2130 Machinery Health ™ Analyzer
  • AMS 2140 Machinery Health ™ How to operate Analyzer?