Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200TCCAG2A  Analog I/O Board
    ❤ Add to collection
  • GE DS200TCCAG2A Analog I/O Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200TCCAG2A  Analog I/O Board

    • ¥22000.00
      ¥24520.00
      ¥22000.00
      ¥22000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

GE DS200TCCAG2A  Analog I/O Board


GE DS200TCCAG2A  Analog I/O Board

Part Number DS200TCCAG2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCCAG2A is a Common Analog I/O Board developed by GE. It is a part of mark V series. The Common Analog I/O Board (TCCA), which is housed in the R5 core, scales and conditions analog signals from the CTBA, TBQA, and TBCA terminal boards. 4-20 mA inputs and outputs, RTD inputs, thermocouple inputs, shaft voltage inputs, and shaft current inputs are among the signals available. The STCA board receives the signals via the 3PL connector. 

 Connectors 2PL - Power distribution from the TCPS board in the R5 core. 3PL - The Data Bus in core R5 that connects the STCA, TCCA, and TCCB boards. Conditioned signals are transferred to the COREBUS via 3PL. JAA - Transports 420 mA output signals to the CTBA terminal board. JBB - Transports the CTBA terminal board's shaft voltage and current signals, as well as 4-20 mA input signals. JCC - RTD input signals from the TBCA terminal board are carried by JCC. 

JDD - RTD input signals from the TBCA terminal board are carried by this bus. JAR/S/T - Transports thermocouple and cold junction input signals from the TBQA terminal board. JC - Transports TCPS power supply diagnostic signals. JEE - Not Typically used. DS200TCCAG2A Configuration Hardware On the TCCA board, there are three hardware jumpers: J1, JP2, and JP3. J1 is used to enable and deactivate the serial RS232 port. JP2 is used to turn off the oscillator during card testing. JP3 is used in the factory for testing. Appendix A contains information on how to configure the hardware jumpers on this board.

 Software The I/O Configuration Editor on the HMI is used to enter I/O configuration constants for thermocouples, RTDs, mA inputs and outputs, and shaft voltage and current settings. Thermocouple Circuit The TBQA terminal board reads the thermocouple inputs. The cold junction circuitry on the TBQA terminal board generates the cold junction signals. The TCCA board uses these values to calculate cold junction compensation. The thermocouple input and compensation value are used by the TCCA board to calculate the actual temperature read by the thermocouple. The value is read by the I/O Engine via the 3PL connector. I/O configuration constants are used to select thermocouple types and curves.C) 

OTHER INFORMATION

As with any General Electric Mark V Series product, this DS200TCCAG2A Common Analog I/O Board was manufactured using multiple product-specific hardware components; contributing towards its intended functionality as a Common Analog I/O Board. Fortunately for our purposes, this DS200TCCAG2A Common Analog I/O Board can additionally be considered a well-documented General Electric product offering, as it is detailed in product-specific instructional manual materials.

Hardware Tips and Specifications

The GE I/O TC2000 Analog Board DS200TCCAG2A features one 80196 microprocessor and multiple PROM modules. It also contains one LED and 2 50-pin connectors. The LED is visible from the side view of the board. The IDs for the 50-pin connectors are JCC and JDD. The GE I/O TC2000 Analog Board DS200TCCAG2A also is populated with 5 34-pin connectors. Both the 50-pin and the 34-pin connectors use ribbon cables to connect to the rest of the DS200TCCAG2A board's assembly. Because of the potential for multiple 34-pin ribbon cables that could be connected to the new board, it is important to know where they connect when the new board is installed. Another consideration with the ribbon cables inherent to this DS200TCCAG2A Common Analog I/O Board is the proper handling technique when you disconnect them from the board. Ribbon cables have minimal support between the connector and the cable attached to them; with this in mind it is easy to pull the wires out of the connector if you tug the cable out of the connector on the board. To avoid that problem, only pull the cable out by holding the connector at the end of the ribbon cable, before gently pulling it out of the connector on the board. Adding to our ribbon cable problem here is that fact that the ribbon cable is comprised of multiple individual strands of copper wire; without taking the ribbon cable apart it is impossible to know if the connections are intact.

The ribbon cables and connectors adopted by this DS200TCCAG2A Common Analog I/O Board are not the only hardware elements present in its assembly. This DS200TCCAG2A Common Analog I/O Board additionally makes use of three total manually-moveable hardware jumpers; included in its assembly for different purposes. The JP1-labeled jumper present in this PCB's assembly is responsible for disabling of the RS-232 serial communications port. The JP2-labeled jumper present in the assembly of the DS200TCCAG2A I/O Board can disable this device's oscillator for card test. Finally, the JP3 jumper included with the DS200TCCAG2A Common Analog I/O Board is included for factory testing purposes only.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice