Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE ds200tccag1b Analog I/O Module
    ❤ Add to collection
  • GE ds200tccag1b Analog I/O Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE ds200tccag1b Analog I/O Module

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

GE ds200tccag1b Analog I/O Module


GE ds200tccag1b Analog I/O Module

Part Number ds200tccag1b Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCCAG1B is a Common Analog I/O Board developed by GE under Mark V series. The CTBA, TBQA, and TBCA terminal boards positioned in the R5 core send analog signals to the Common Analog I/O Board (TCCA), which is situated in the R5 core. 420 mA inputs and outputs, RTD inputs, thermocouple inputs, shaft voltage inputs, and shaft current inputs are some of the signals that make up this group. Through the 3PL connector, the signals are written to the STCA board. DS200TCCAG1B Configuration Hardware On the board, there are three hardware jumpers labeled J1, JP2, and JP3. 

The serial RS232 port can be enabled or disabled using J1. For card testing, the oscillator is turned off using JP2. For factory testing, JP3 is used. Software The HMI's I/O Configuration Editor is where the settings for the thermocouples, RTDs, mA inputs and outputs, and shaft voltage and current are entered. 4-20 mA TCCA Input Circuit The circuitry for the 4-20 mA input signals is provided by the board. Through the JBB connector, the signals are read from the CTBA terminal board. The voltage drop is measured by the board and written to the I/O Engine via the 3PL connector as the transducer current is reduced across a burden resistor. 4-20 mA Output Circuit for TCCA The circuitry for driving 420 mA outputs to the CTBA terminal board via the JAA connector is provided by the board. Typically, these signals are utilized to power distant instruments for monitoring. 

 RTD Circuit TCCA The circuitry that draws excitation for the RTDs from the TBCA terminal board. When the temperature varies, the resistance changes, causing the voltage on the RTD to change. A constant current is fed through the RTD. The voltage signal is measured, scaled, and adjusted by the board. The board reads the RTD signals from the TBCA terminal board via the JCC and JDD connectors. The 3PL connector is used to transmit the signals to the I/O Engine. I/O configuration constants are used to choose the kind of RTD. DS200TCCAG1B Thermocouple Circuit The TBQA terminal board reads the thermocouple inputs. The cold junction circuitry on the TBQA terminal board produces the cold junction signals. 

It computes the cold junction compensation using these variables. The actual temperature read by the thermocouple is determined using the thermocouple input and compensation value. Through the 3PL connector, the I/O Engine reads the value. I/O configuration constants are used to choose the types and curves of thermocouples. Shaft Monitoring The board is in charge of monitoring the voltage and current of the turbine shaft. The JBB connector is used to read these signals from the CTBA terminal board. 

Through the 3PL connector, the signals are written to the I/O Engine.DS200TCCAG1B (GE I/O TC2000 Analog Board) features one 80196 microprocessor, multiple PROM modules, one LED and two 5-pin connectors. From the side view of DS200TCCAG1B (Mark V series), you can see the LED. JCC and JDD are the ID?s for the 50-pin connectors.A programmable logic device and 3 jumpers also occupy DS200TCCAG1B (GE I/O TC2000 Analog Board). Usually a site will install a replacement that is just like the original DS200TCCAG1B (Mark V series) when you replace DS200TCCAG1B (Mark V series). 

The drive will function the same as before, prior to the replacement DS200TCCAG1B (Mark V series).What enables DS200TCCAG1B (GE I/O TC2000 Analog Board) to perform the same? The jumpers from the ?defective? DS200TCCAG1B (Mark V series) can be set the same on the new DS200TCCAG1B board. The configuration will be identical and offer the same processing.?In order to have correct jumper placement, remove the defective DS200TCCAG1B (Mark V series) and place it on a clean, level surface. 

Next you?ll have to remove the replacement DS200TCCAG1B (Mark V series) from the static protective bag and put it next to the defective DS200TCCAG1B (Mark V series) on a flattened static protective bag. Be sure to wear a wrist strap when examining the jumpers on the defective DS200TCCAG1B (Mark V series), then correct the new DS200TCCAG1B (Mark V series) board.From the extensive product testing, all versions of DS200TCCAG1B (Mark V series) are compatible to the drive so it will process the same when installed in the drive.

Instructions and warnings related to the operation of the product:

The following specifications must be strictly observed:

 The technical specifications and typical applications of the product system must be strictly observed.

 PERSONNEL TRAINING: Only trained personnel may install, operate, maintain or repair the product system. These personnel must be instructed on the

These personnel must be instructed and briefed on the conditions in the hazardous area.

 Unauthorised modifications: No modifications or structural changes may be made to the product system.

 Maintenance Responsibility: It must be ensured that the product system is used only under appropriate conditions and in a condition fully suitable for use.

 Working environment: The user must fulfil the specified environmental conditions:

Safety regulations

The following safety regulations must be fully observed when (maintenance) work is carried out on the product system:

1 Disconnect completely.

2 Secure to prevent reconnection.

3 Confirm that the installation has been completed.

4 Perform grounding and short-circuiting.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide