Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE
    ❤ Add to collection
  • GE IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE
    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE

GE IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE

Part Number is420ucsch1b Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS420UCSCH1B is a Quad Core Controller manufactured and designed by General Electric. It is a part of the Mark VIe Series used in GE Distributed Control Systems. It is a version of the quad-core controller that is used with the QNX Neutrino operating system. TMR, Simplex, and Dual redundancy are supported by the component. The QNX operating system is used in high-speed, highly reliable industrial applications. 

Another type of technology used on this controller is Embedded Field Agent (EMA) technology, which allows Predix cloud-based applications and possibly web applications to be applied over a stable connection, allowing real-time data to be delivered to the connecting controllers. IS420UCSCH1B Features The controller comes with 4 GB of DDR3-1333 SDRAM, which is a type of memory used in computers and other digital devices for high-speed data storage. The controller has 5 Ethernet ports, which allow it to connect to other devices and networks for data transfer and communication. 

The controller uses ControlST as its Human-Machine Interface (HMI), which is a software application used to interact with and control the device. The Mark VIe quad-core controller runs high-speed, high-reliability industrial applications using real-time hypervisor technology and QNX Neutrino, a real-time, multi-tasking operating system (OS). PredixTM cloud-based apps and/or locally hosted web applications are applied through a secure connection and delivered real-time data using embedded field agent (EFA) technology. A software package tailored to the UCSCH1x controller's use is preloaded. It leverages IONet interfaces as a turbine or balance of plant (BoP) controller and runs Mark VIe firmware and applications. 

Only supporting Mark controls I/O packs and controllers, IONet is a private special-purpose Ethernet. To synchronize the clocks of the I/O modules and controllers to within 100 microseconds, IEEE 1588 protocol is employed through the IONet interfaces. With the IONet connections, external data is transmitted to and from the controller's control system database. To the I/O modules, this also refers to process inputs and outputs. The UCSC controller lacks any application I/O, in contrast to conventional controllers that host application I/O on a backplane. Operation The operation of the system involves several key aspects, including the installation of the ToolboxST application, configuring the UDH network communication, and establishing the necessary IP address for communication with site HMIs. Here is an expanded explanation of these operations: ToolboxST Application Installation: To facilitate configuration and management tasks, the ToolboxST application is typically installed on a minimum 4 GB unencrypted flash drive. 

This flash drive serves as the storage medium for the application and contains the necessary files and settings. The ToolboxST application provides a user-friendly interface for configuring various aspects of the system, including network communication. UDH Network Configuration: The UDH (User Datagram Header) network is utilized for communication within the system. During the configuration process, the ToolboxST application is employed to define the communication parameters for the UDH network. This involves setting up network addresses, ports, protocols, and other relevant settings. The configuration ensures that the control module can establish reliable and secure communication with other devices and systems within the network. 

Default IP Address: By default, the control module is assigned the IP address 192.168.101.111. This IP address serves as the initial configuration for the module's network connectivity. However, it is important to note that this default IP address may need to be modified to match the specific requirements and setup of the site or network where the system is deployed. Configuring Relevant UDH IP Address: In order for the control module to effectively communicate with the site HMIs (Human-Machine Interfaces), it must be configured with the relevant UDH IP address. This IP address is specific to the UDH network and enables seamless communication between the control module and the site HMIs. 

Through the ToolboxST application, the control module's IP address can be customized and set to the appropriate value that aligns with the network configuration and addressing scheme of the site. Virtual Network The virtual network feature in controllers is a powerful capability provided by the hypervisor, enabling seamless communication and data exchange between virtual machines (VMs) running on the same physical machine or across multiple physical machines in the network. The virtual network functions similarly to a conventional Ethernet network, facilitating data transmission between VMs just as physical Ethernet networks facilitate data transfer between physical machines. Virtual network plays a crucial role in connecting different components of the system and enabling efficient data transfer. Specifically, it facilitates data exchange between the Embedded Field Agent (EFA) and the Mark VIe control, both of which run as separate VMs on the UCSCH1 controller. 

Here's how the virtual network enables data communication between the EFA and the Mark VIe control: EFA and Mark VIe Control VMs: In the UCSCH1 controller, the EFA and the Mark VIe control are both running as virtual machines (VMs) within the same hypervisor environment. Each VM operates independently, emulating separate computing environments within the same physical machine. Data Transfer through Virtual Network: When data needs to be exchanged between the EFA and the Mark VIe control, it is transmitted through the virtual network provided by the hypervisor. 

The virtual network efficiently routes the data between the two VMs, enabling seamless and fast communication. Connection to the Cloud: The EFA, being an essential component for remote monitoring and management, requires a connection to the cloud for data exchange with remote servers or cloud-based applications. This connection allows the EFA to send data to the cloud and receive commands or updates from the cloud-based systems. Physically Managed Switch for Network Division: To maintain proper network segregation and security, a physically managed switch is used to divide the networks. The physically managed switch creates distinct network segments, ensuring that the Mark VIe control, which contains sensitive control data, remains isolated from the cloud network. This network division helps protect critical control systems from potential external threats. 

By leveraging the virtual network, the controller achieves efficient and secure data communication between its different VMs, enabling seamless coordination and control of various components in the system. The integration of a physically managed switch adds an extra layer of security, ensuring the safety and integrity of critical control systems while allowing the EFA to establish connections with cloud-based systems for enhanced functionality and remote monitoring capabilities. Ethernet Ports/Controller Communications Support 3 IONet ports (R/S/T) for I/O module communications (simplex, dual, TMR, and Shared I/O supported). ENET 1 - EGD/UDH communications to ToolboxST PC, HMIs, UCSCS2A Safety controller, and GE PACSystems products. 

Modbus TCP Slave, Read/Write. ENET 2 - Secondary UDH communications, Modbus TCP Slave and OPC UA. IICS Cloud port for Embedded Field Agent (EFA). Module Ports The control module is equipped with various ports on its front and bottom panels, serving different purposes and enabling connectivity and functionality. Here is an expanded explanation of each port: Ethernet Ports: The front panel of the module features five Ethernet ports. These ports are used for establishing network connections and enabling communication with other devices or systems within the network. Predix Connectivity Port: Located on the bottom panel, this Ethernet port is specifically designated for connectivity to Predix, a cloud-based platform developed by GE. It facilitates data exchange and integration with Predix for enhanced monitoring and analytics capabilities. 

USB Ports: The module has two USB ports, which are primarily used for specific functions. These ports are typically utilized during the initial setup of the UDH (User Datagram Header) network IP address. Additionally, they can be utilized for a restore function, allowing for the restoration of the module's configuration or software. COM Port: The COM port is a serial communication port that employs an RJ-45 connector and operates at a speed of 115200 bits per second (bit/s). The configuration for this port is 8N1, which denotes eight data bits, no parity bit, and one stop bit. This port does not employ flow control and is commonly used by GE for troubleshooting purposes in the field. It supports the serial redirection of UEFI-setup, facilitating configuration adjustments and troubleshooting activities. Display Port: The module features a Display Port, although it is disabled after the system's startup. 

The Display Port is typically used to connect an external display device for video output, but its functionality is limited or deactivated once the module is operational. microSD Port: While the module includes a microSD port, it is not currently supported. The microSD port is designed to accommodate a microSD card, which can be utilized for storage purposes. However, in this particular system, the functionality of the microSD port is not enabled or actively supported. Product Attributes Altitude for Normal Operation: Designed to operate within an altitude range of 0-1000 meters. 

It can function reliably in environments with varying atmospheric pressure, ranging from 101.3 to 89.9 kilopascals (kPa). This attribute ensures that the module can maintain optimal performance even at different altitudes. Dimensions with Mounting: The module has specific dimensions when considering its mounting. It has a height of 8.03 inches, a depth of 5.99 inches, and a width of 2.17 inches when properly mounted. These dimensions provide guidance for installation and integration into the overall system architecture. HMI (Human-Machine Interface): Supports ControlST V07.00.00C or later as its human-machine interface. The HMI facilitates interaction between the module and the human operator, allowing for intuitive control, monitoring, and configuration of the system. 

Memory Type: The module is equipped with 4 GB DDR3-1333 SDRAM memory. This type of memory is commonly used for storing and processing data within the module. The 4 GB capacity provides sufficient space for efficient data management and enables the module to handle complex control algorithms and calculations effectively. Number of Ethernet Ports: Features a total of six Ethernet ports. Five of these ports are located on the front panel, providing convenient access for networking purposes. Additionally, one Ethernet port is available on the bottom of the module, specifically designed for Predix connectivity. 

These Ethernet ports facilitate seamless communication and data exchange between the module and other devices or systems within the network. NVSRAM (Nonvolatile Static Random-Access Memory): The module incorporates NVSRAM, which includes 3067 nonvolatile program variables, 64 totalizers, and 338 forces. NVSRAM allows the module to retain critical information, such as program variables and configuration settings, even during power outages or system failures. This attribute ensures data integrity and reliability, crucial for applications where data loss is not acceptable. 

Platform Configuration Supported Features: Supports EFA (Embedded Functionality Automation), Embedded EtherCAT (Ethernet for Control Automation Technology), and Embedded PPNG (Predix Process & Notification Gateway) as its platform configuration features. These advanced networking capabilities enhance the module's connectivity, compatibility, and overall performance in complex industrial control systems. Storage Temperature: The module is designed to withstand a wide range of storage temperatures, from -40 to 85 degrees Celsius. This attribute allows the module to be stored safely in environments with extreme temperature conditions, ensuring its durability and long-term reliability. Diagnostics The Control Module's circuit cards include system (software) limit checking, high/low (hardware) limit checking, and comprehensive diagnostics for abnormal hardware conditions. 

System limit checking consists of two limits for each analog input signal, which can be set with the I/O Configurator in engineering units for high/high, high/low, or low/low. Each input limit can be configured for latching/non-latching and enable/disable. System limit checking logic outputs are generated per frame and stored in the database (signal space) for use in control sequencing and alarm messages. Each analog input has high/low (hardware) limit checking, with typically two occurrences required before an alarm is triggered. These limits are not programmable and are chosen to be outside the normal control requirements range but within the linear hardware operational range (before the hardware reaches saturation). 

The software maintenance tools provide access to diagnostic messages for hardware limit checks and all other hardware diagnostics for the card (Control System Toolbox). In the database, each card has a composite logic output, and another logic output indicates a high/low (hardware) limit fault of any analog input or the associated communications for that signal. Characteristics HMI: ControlST - The human-machine interface (HMI) used in this system is ControlST. ControlST is a software or hardware component that allows users to interact with and control the system. Trip Solenoid Rating: 125 V dc - The trip solenoid used in the system has a rating of 125 volts direct current (V dc). The trip solenoid is an electromechanical device that is used to trip or close circuit breakers or other devices in response to specific conditions. Span: -8 mV to +45 mV - The span refers to the range of values that can be measured or controlled. In this case, the system has a span of -8 millivolts (mV) to +45 mV. 

This indicates that the system can measure or control signals within this voltage range. Power supply voltage: 28 V dc - The power supply voltage for the system is 28 volts direct current (V dc). This voltage is used to provide power to the various components of the system. Voltage Range: 18 - 32 VDC - The system operates within a voltage range of 18 to 32 volts direct current (VDC). This indicates that the system is designed to function properly within this voltage range. Platform Configuration Supported Features: EFA, Embedded EtherCAT, and Embedded PPNG - The platform configuration of the system supports several features, including EFA (Electronic Function Blocks), Embedded EtherCAT (Ethernet for Control Automation Technology), and Embedded PPNG (Powerful Programmable Numeric Gateway). These features enhance the system's capabilities and functionalities. 

NVSRAM: 3067 Nonvolatile Program Variables, 64 Totalizers, and 338 Forces - The system has NVSRAM (Nonvolatile Static Random Access Memory) that can store 3067 nonvolatile program variables, 64 totalizers, and 338 forces. NVSRAM is a type of memory that retains its stored information even when power is removed from the system. Number of Ethernet Ports: 6 - The system is equipped with six Ethernet ports. Ethernet ports are used for connecting the system to a network, allowing for communication with other devices or systems. Altitude for Normal Operation: 0-1000 m at 101.3 to 89.9 kPa - The system is designed to operate normally within an altitude range of 0 to 1000 meters. The atmospheric pressure range for normal operation is 101.3 to 89.9 kilopascals (kPa). 

HMI: ControlST V07.00.00C or Later - The specific version of the ControlST HMI used in the system is V07.00.00C or later. This indicates the minimum version requirement for compatibility and functionality with the system. Cable Separation and Routing When it comes to cable separation and routing in control systems, it is important to consider certain factors to ensure optimal system performance. One significant consideration is the prevention of electrical noise interference caused by different voltage levels in the cabling. Electrical noise can disrupt the operation of microprocessor-based control systems, leading to malfunctions or unreliable performance. To mitigate the risks associated with electrical noise interference, it is essential to follow proper guidelines and recommendations during the installation of cables. Before proceeding with the cable installation, it is advisable to consult the relevant manuals and documentation provided by the manufacturer or system designer. 

These manuals often contain specific instructions and precautions for cable installation in various scenarios. If the installation site presents unique circumstances or if the guidelines mentioned in the documentation cannot be met, it is crucial to seek further guidance or clarification. During the planning stages of system revamps or upgrades, adherence to level rules is highly recommended. Level rules refer to established standards and guidelines for cable separation and routing in control systems. These rules ensure that cables are appropriately organized and spaced to prevent interference and optimize system performance. By considering level rules during the planning process, the chances of a trouble-free installation and proper application of the control system are significantly increased. By following these guidelines and best practices, potential issues arising from electrical noise interference can be minimized. Proper cable separation and routing help maintain the integrity of the control system, ensuring reliable and efficient operation. It is important to prioritize these considerations during the design, installation, and maintenance phases to maximize the performance and longevity of the control system. Environment Features The Mark VIe control system cabinet should be installed in an environmentally controlled room or in the control room itself. The cabinet should be installed in a location where the floor surface allows for attachment in only one plane (a flat, level, and continuous surface). The mounting hardware is supplied by the customer. 

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer