  • GE IS200TBCHIH2B Contact Input Terminal Board
    ❤ Add to collection
  • GE IS200TBCHIH2B Contact Input Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200TBCHIH2B Contact Input Terminal Board

    • ¥28974.01
      ¥28734.58
      ¥28974.01
      ¥28974.01
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.780KG
    • Quantity:
    • (Inventory: 60)
Description

GE IS200TBCHIH2B Contact Input Terminal Board


GE IS200TBCHIH2B Contact Input Terminal Board

Part Number IS200TBCHIH2B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200TBCHIH2B is a Terminal Board developed by GE. It is part of Mark VI series. Mark VI integrates multiple functions, including control, monitoring, and protection, into a centralized system, enabling efficient operation and oversight of critical industrial processes. 

 SYSTEM APPLICATION SOFTWARE The application software operates in a sequential manner and is visually represented in a dynamic state through a ladder diagram format, providing an intuitive interface for system control and monitoring. Maintenance personnel are empowered with various capabilities, enabling them to make alterations to the system: Modification Capabilities: Maintenance personnel possess the authority to add, delete, or modify analog loops, sequencing logic, tuning constants, and other essential parameters within the software framework. This flexibility allows for swift adaptations to accommodate evolving system requirements. User-Friendly Interface: The software interface facilitates ease of editing by enabling data points to be selected and seamlessly "dragged" across the screen from one functional block to another. This drag-and-drop functionality simplifies the editing process, enhancing efficiency in making changes or adjustments. Logic Forcing: Maintenance personnel can implement logic forcing, providing the ability to override system logic temporarily for diagnostic or testing purposes. 

Analog Forcing: Allows manual input of analog values, enabling simulation or testing of specific scenarios within the system. Trending at Frame Rate: Real-time data visualization and analysis through trending features, enabling observation and analysis of system behavior at the frame rate level. Availability and Compatibility: The software maintenance tools, housed within the Control System Toolbox, are accessible via the Human-Machine Interface (HMI). Additionally, they are available as a standalone software package compatible with virtually any Windows 95 or NT based PC. This ensures accessibility and convenience for maintenance and troubleshooting tasks, even beyond the confines of the primary control system interface. TERMINAL BLOCK FEATURES Terminal blocks play a crucial role in facilitating secure connections within the Mark VI system. Here are the key features of the 24-position pluggable barrier terminal block (179C9123BB) commonly used in Mark VI terminal boards: Material Composition: Constructed from a durable polyester resin material, providing excellent thermal resistance with a rating of 130). This ensures reliability even in demanding operating conditions. Terminal Rating: Terminal block rated for 300 volts and 10 amperes, meeting UL Class C general industry standards. It offers a creepage of 0.375 inches (9.525 mm) and a strike of 0.250 inches (6.35 mm), ensuring safety and compatibility with various electrical components. Certification: UL and CSA code approved, complying with industry standards for safety and quality assurance. 

This certification underscores the terminal block's reliability and suitability for use in critical applications. Finishing: Screws finished in zinc clear chromate and contacts coated in tin, providing corrosion resistance and ensuring long-term performance and durability in diverse environmental conditions. Number Labeling: Each block screw is labeled with numbers 1 through 24 or 25 through 48 in white, facilitating easy identification and wiring of connections, streamlining installation and maintenance processes. Recommended Torque: The recommended screw tightening torque is 8 in lbs, ensuring optimal and secure connections without risk of over-tightening or damage to components. WIRING AND CIRCUIT CHECKS Verification of Power Wiring: Verify that all incoming power wiring aligns precisely with the provided elementary drawings. 

Adherence to Approved Wiring Practices: Ensure that the incoming power wiring conforms strictly to approved wiring practices, as outlined earlier in this chapter. Inspection of Electrical Terminal Connections: Check that all electrical terminal connections are securely tightened to prevent any potential hazards. Detection of Wiring Damage: Inspect all wiring to ensure that none has been damaged or frayed during installation. If any damage is detected, promptly replace the affected wiring. Verification of Incoming Power: Confirm that the incoming power (125 V dc, 115 V ac, 230 V ac) matches the correct voltage and frequency specifications. Additionally, ensure that the power is clean and free of any noise interference. 

Adjustment of AC to DC Converters (if applicable): If AC to DC converters are utilized, verify that they are set to the correct voltage (115 V or 230 V ac) by selecting the appropriate jumper positions (JTX1 or JTX2) located on the front of the converter. Installation of BJS Jumper (if applicable): In installations comprising multiple PDMs interconnected within a 125 V dc system, ensure that the BJS jumper is installed in one and only one PDM. This arrangement is imperative to prevent impedance reduction to a level where the 125 V dc fails to meet the Not Hazardous Live requirement.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Toshiba TE3 Soft Starter Installation, Operation, and Maintenance Complete Guide
  • TOSHIBA N300 Pro NAS Hard Drive
  • TOSHIBA N300 NAS Hard Drives
  • Toshiba e-STUDIO Multifunctional Digital System Technical Specifications and Application Guide
  • TOSHIBA V200 Series PLC Programming and Safety Application Guide
  • TOSHIBA Unified Controller nv series™ Unified Controller nv series™
  • Toshiba Discrete IGBT Product Technology Analysis and Application Guide
  • Technical Analysis and Application of Toshiba V-Series Integrated Control System
  • TOSVERT VF-AS3 series 600V industrial frequency converter
  • Toshiba VRF Dx coil interface device
  • Toshiba T1-16S Programmable Controller I/O Module Detailed Explanation
  • CE 680 M511 industrial piezoelectric accelerometer
  • Hardware Explanation of Meggitt VM600 MPS Mechanical Protection System
  • Meggitt Vibro meter VM600Mk2 Mechanical Protection and Condition Monitoring System
  • WAGO MCS Connection System
  • WAGO 281-611 Fuse Terminal Analysis
  • Watlow PPC-2000 System Deployment and Configuration Guide
  • Watlow MLS Controller Guide
  • Watlow 8LS Controller Setup Guide
  • Watlow Anafaze System 32 Hardware Installation Guide
  • Watlow ANAFAZE 12LS Installation and Operation Technical Guide
  • Baldor NextMove ST Motion Controller Technical Guide
  • Baldor MotiFlex e100 Servo Drive Installation Guide
  • Baldor FlexDrive II AC Guide
  • Baldor MicroFlex Servo Drive Professional Installation Guide
  • ABB MicroFlex servo drive characteristics and installation guide
  • Baldor BSM Series AC Servo Motor Analysis
  • Baldor Reliability CDPT3320 DC Motor
  • Baldor Reliability NEMA Super-E Ultra High Efficiency Motor Comprehensive Guide
  • Baldor Reliance Full Horsepower DC Motor Comprehensive Guide: From Technical Specifications to Industrial Application Selection
  • Comprehensive Guide to Baldor Motion Control Accessories: HMI Panels, Industrial Cables, Power Supplies, and EMC Filters
  • HIMA HICore 1 In Depth Analysis: A Comprehensive Guide to Functional Safety SoCs, Evaluation Kits, and T Ü V Certification
  • HIMA HIJunctionBox: Creating a New Era of Distributed Intelligent Security Platform
  • HIMA HIMatrix F35 Safety Controller: Specification Manual, SIL 3 Programming and Installation Guide
  • HIMA HIQuad X System Manual: Comprehensive and in-depth analysis of HIMA SIL 3 safety automation system
  • Deep Analysis of HIMA HIMax Safety Control System: Architecture, Redundancy, and Engineering Application Guidelines
  • In depth analysis of HIMA Planar4 system: SIL 4 level hard wired safety logic solution
  • What are the core protection mechanisms of WOODWARD Vertex's anti surge control?
  • Woodward Vertex Compressor Control System: Function, Application, and Installation Details
  • Woodward easYview miniSCADA visualization solution
  • Woodward easyYview Series: Technical Analysis of Mini SCADA Remote Control Panel Designed for Generator Sets and Switchgear
  • Woodward MicroNet Plus: High reliability redundant control system for prime mover control
  • Woodward easyYgen LS-6XT: A Multi Circuit Breaker Control Solution for Complex Power Management
  • Woodward easyYgen LS-6XT Circuit Breaker Control Unit: Technical Characteristics, Installation and Application Guide
  • Woodward LS-521 V2 (Option K12) Circuit Breaker Control Unit
  • Woodward MicroNet TMR 5009 Digital Control System: Authoritative Guide to Hardware Installation and Configuration
  • Woodward MicroNet ™ Analysis and Application of Simplex and Plus Digital Control Systems
  • WOODWARD MSLC-2XT™ Master Synchronizer and Load Control
  • Woodward DSLC Digital Synchronizer and Load Controller: Installation, Operation, and Troubleshooting Guide
  • WOODWARD DSLC-2 Digital Synchronizer and Load Control
  • From Beginner to Proficient: Woodward easyYgen-3000 Controller Interface Configuration, CANopen, J1939 and Modbus Communication Practical Guide
  • WOODWARD easYgen-3000 Series (Package P1) Genset Control
  • WOODWARD ® ProTech‐SX Safety System with Integrated Overspeed Protection
  • Woodward ProTech SX Simplex System: Turbine Single Channel Safety Protection System
  • Woodward QuickTrip Electro Hydraulic Trip Module Components: High Reliability Turbine Safe Shutdown Solution
  • WOODWARD QuickTrip Electro-Hydraulic Trip Block Assembly
  • WOODWARD VariStroke Hydraulic Power Cylinder (VHPC)
  • WOODWARD VariStroke GI single acting electro-hydraulic actuator: a reliable solution for turbine control
  • Woodward VariStroke DX hydraulic servo dual redundant sled
  • Woodward VariStroke-I electro-hydraulic actuator: an innovative solution for steam turbine valve control
  • WOODWARD MicroNet TMR ® OpView of 5009 Digital Control System ™ Interface Operation Manual
  • WOODWARD 5009XT Fault-Tolerant Control
  • Woodward PG-PL Hydraulic Governor: Reliable and Accurate Engine and Turbine Speed Control Solution
  • WOODWARD 2301A Speed Control Controller: A Classic and Reliable Engine and Turbine Speed Control Solution
  • XP POWER VFR05 Series 5W Convertible Plug AC-DC Adapter
  • XP POWER VFL05 Series 5W Wall Mounted AC-DC Power Adapter
  • XP POWER AQM200 Series 200W Natural Cooling Medical Grade AC-DC External Power Supply
  • XP POWER CB Series 1W Natural Cooling Micro High Voltage DC-HVDC Converter
  • XP POWER CDX Series 1500W Dual Frequency RF Power Supply
  • XP POWER RDF25 Series 5W Bottom Cooling DC-DC Converter
  • XP POWER ITX Series 6W DC-DC Converter: A Concise and Efficient Solution
  • XP Power Technical Guide: In Depth Analysis of AC/DC Conversion, System Topology, and High Reliability Design
  • XP POWER C Series Micro Stabilized High Voltage DC-DC Converter
  • XP POWER EHL05 Series 5W AC-DC Power Supply: A Wide Input Solution Designed for 480VAC Systems
  • XP Power: The world's leading expert in power conversion and its full range of solutions
  • XP POWER HDA1500 Series 1.5kW High Power AC-DC Power Supply
  • XP POWER SMP350 Series Fan Cooling 350W AC-DC Power Supply
  • XP POWER MP Series 300-2400 Watts AC-DC Power Supply
  • How to install the YAMAHA RCX40 four axis robot controller?
  • HIMA HIMax X-AO 16 01 Analog Output Module: SIL 3 Safety Certification and Key Technical Features
  • HIMA HIMax ® System Manual is applicable to safety related control systems
  • Hirschmann Industrial Ethernet Switch
  • YASKAWA A1000 series AC frequency converter
  • HIRSCHMANN MACH1040 family Full Gigabit Industrial Ethernet Ruggedized Switch
  • How to operate the Hirschmann MICE series media module and expansion module?
  • How to install Hirschmann MS20/MS30 series industrial Ethernet switches?
  • Hirschmann GUI Graphical User Interface Industrial ETHERNET (Gigabit-)Switch RS20/RS30/RS40, MS20/MS30
  • HIRSCHMANN MICE series modular industrial communication equipment
  • TOSHIBA TOSBERT VF-AS3 series
  • TOSHIBA MG08-D SERIES ENTERPRISE CAPACITY HDD
  • Triconex Tricon™ v9–v11 Systems Planning and Installation Guide
  • XYCOM XVME-100 memory module
  • ABB Ability™ Symphony® Plus MR Series
  • BENTLY 3500/15 AC and DC Power Supplies
  • HITACHI S10VE Programmable Controller
  • ABB SYNCHROTACT ® 5 synchronous devices
  • YASKAWA SGMCS series direct drive servo motor
  • YASKAWA GA700 series AC frequency converter
  • YASKAWA ∑ - V series AC servo drive
  • YASKAWA S-7 series linear servo
  • YASKAWA GA500 series AC micro frequency converter
  • YASKAWA 1000 series frequency converter
  • YASKAWA 120 Series I/O Modules
  • YASKAWA MEMOCON-SC 2000 series reversible counter module
  • YASKAWA Machine Controller MP2000 Series
  • Yaskawa VARISPEED-626M5 frequency converter
  • Yaskawa CP-9200SH Controller
  • WESTINGHOUSE eVinci ™ Micro reactor
  • WESTINGHOUSE HC series molded case circuit breaker
  • WESTINGHOUSE MAX-VH ™/ MAX-VHP ™ Series vertical hollow shaft induction motor
  • WESTINGHOUSE Alpha Plus Series Low Voltage Distribution System
  • WESTINGHOUSE Three Phase Induction Motors
  • WESTINGHOUSE iGen5000 Digital Inverter Generator
  • WESTINGHOUSE E510 series compact AC frequency converter (VFD)
  • WESTINGHOUSE E-Series MCCB (Molded Case Circuit Breaker)
  • WESTINGHOUSE Transformer Product Line
  • Emerson Ovation OCR1100 Controller
  • BENDER Isolated Power Panels
  • Bender LifeGuard® LG2-Series Protection Panels
  • Bender LINETRAXX ® CTAC series AC measurement current transformer
  • Bender GPM series grounding power module
  • BENDER LINETRAXX® CTUB100 series AC/DC sensitive measuring current transformers (type B)
  • Bender LifeGuard ® LG2 series protective panel
  • BENDER ISOMETER ® Iso685 series
  • BENDER Greenlee 555C Electric Pipe Bending Machine
  • BENDER ISOMETER® iso685(W)-D/-S Insulation Monitoring Device
  • BENDER LINETRAXX ® VMD420 Three phase Voltage Frequency Monitor
  • BENDING 77 Series Electric Bender with Single Shoe Groups