ABB TU841 Communications - S800 I/O Communication interfaces
General info
Article number:3BSE020848R11
Communication protocol:Modulebus
Master or slave:N/A
Line redundancy:Yes
Hot Swap:No
Type:Redundant TB840/TB840A, Single I/O, Single Power
Power input:24 V d.c (19.2 - 30 V)
Mounting:Vertical or Horizontal


The TU841 is a module termination unit (MTU) for redundant configuration of Optical ModuleBus Modem TB840/TB840A, for use with non-redundant I/O.

The MTU is a passive unit having connections for power supply, a single electrical ModuleBus, two TB840/TB840A and a rotary switch for cluster address (1 to 7) setting.
Four mechanical keys, two for each position, are used to configured the MTU for the right types of modules. Each key has six positions, which gives a total number of 36 different configurations. The configurations can be changed with a screwdriver.
Termination Unit TU840 connects TB840/TB840A to redundant I/O. Termination Unit TU841 connects TB840/TB840A to non-redundant I/O.
Features and benefits
• A rotary switch for cluster address setting
• Mechanical keying prevents insertion of wrong module type
• Single ModuleBus connection
• Latching device to DIN rail for locking and grounding
• DIN rail mounted


Product Overview

ABB TU841 Communications - S800 I/O Communication Interfaces is a high-performance communication interface module designed specifically for S800 I/O systems, playing a critical bridging role in industrial automation control systems. It can achieve efficient data communication and interaction between S800 I/O systems and various controllers, upper computers, and other external devices, providing a solid foundation for building complex and reliable industrial automation networks. It is widely used in multiple industries such as energy, manufacturing, and transportation, helping enterprises improve their automation level and production efficiency.


Specification parameters

Communication Protocol: Supports multiple industrial standard communication protocols, including PROFIBUS DP, Modbus TCP, Ethernet/IP, etc., which can flexibly adapt to different brands and types of industrial equipment, achieving seamless communication between multiple devices.

Transmission rate: The transmission rate varies depending on different communication protocols. Under the PROFIBUS DP protocol, the maximum transmission rate can reach 12Mbps; Under Modbus TCP and Ethernet/IP protocols, Ethernet based transmission rates can achieve 10/100Mbps adaptive, meeting the requirements of high-speed data transmission.

Interface type: Equipped with a variety of interfaces, including PROFIBUS DP interface, Ethernet RJ45 interface, etc., for easy connection with different devices. Among them, the PROFIBUS DP interface adopts a standard 9-pin D-type connector, and the Ethernet RJ45 interface complies with the IEEE 802.3 standard.

Working voltage: The working voltage range is 24V DC ± 10%, with good power adaptability and stable operation within a certain voltage fluctuation range, ensuring communication continuity.

Working temperature: The working temperature range is -25 ℃ to+70 ℃, and the storage temperature range is -40 ℃ to+85 ℃. It can operate normally under harsh industrial temperature conditions and adapt to the needs of different industrial scenarios.

Protection level: reaching IP20 protection level, it can effectively prevent solid foreign objects larger than 12mm from entering, suitable for most indoor industrial environments. If it needs to be used in more harsh environments, measures such as protective cabinets can be taken.

Core functions

Multi protocol communication: With support for multiple industrial standard communication protocols, TU841 can serve as a communication conversion hub between devices with different protocols. In large-scale industrial automation projects, on-site sensors and actuators using PROFIBUS DP protocol can be connected to upper level monitoring systems based on Ethernet/IP protocol to achieve interconnectivity between heterogeneous devices, break down communication barriers between devices, and improve system integration and compatibility.

High speed data transmission: Based on Ethernet communication interfaces and high transmission rates, it can achieve fast and stable transmission of large amounts of data. In industrial production process monitoring scenarios, various data from on-site equipment (such as temperature, pressure, flow rate, etc.) can be collected and transmitted in real time to the control center, allowing operators to timely grasp the production operation status and quickly issue control instructions to on-site equipment, ensuring efficient and accurate control of the production process.

Equipment status monitoring: Equipped with equipment status monitoring function, it can monitor the real-time operation status of communication interfaces themselves and connected devices. Intuitively display the working status, communication connection status, fault information, etc. of the device through indicator lights, diagnostic software, and other means. When there are abnormal situations such as communication interruptions or equipment failures, timely alarm signals can be issued to facilitate technicians to quickly locate and handle the problem, improving the maintainability and reliability of the system.

Redundant design support: Supports redundant configuration and can form a redundant communication system with another TU841 module. When the main module fails, the backup module can automatically take over communication tasks, ensuring uninterrupted system communication and greatly improving the reliability and stability of industrial automation systems. It is suitable for critical industrial application scenarios that require extremely high reliability, such as power generation, petrochemicals, and other industries.


Precautions

Installation environment: It should be installed in a dry, well ventilated environment away from strong electromagnetic interference sources to avoid damage to equipment caused by harsh environments such as high temperature, humidity, and corrosive gases. The installation location should ensure sufficient space for heat dissipation and equipment maintenance. It is recommended to install it in a standard industrial control cabinet and maintain good ventilation and heat dissipation conditions.

Power connection: Provide stable 24V DC power to the module, ensuring that the power supply voltage is within the specified operating voltage range (24V DC ± 10%). Use power cords that meet the specifications and ensure a secure power connection to avoid abnormal module operation caused by unstable power supply or poor contact. It is recommended to equip overvoltage and overcurrent protection devices to prevent module damage caused by abnormal power supply.

Communication connection: When conducting communication connection, strictly follow the instructions in the product manual to correctly connect various communication cables, ensuring that the interface connection is firm and the contact is good. Use appropriate communication cables (such as PROFIBUS DP dedicated cables, Category 5e and above Ethernet cables, etc.), and pay attention to cable length limitations and laying requirements to avoid affecting communication quality due to cable issues. For systems with redundant configurations, it is important to ensure that the redundant connections are correct and error free.

Parameter configuration: When configuring communication parameters, carefully check each parameter setting to ensure that it matches the parameters of the connected device. Different communication protocols have different parameter requirements (such as baud rate, station address, data format, etc.), and configuration errors may lead to communication failures. After the configuration is completed, conduct sufficient testing to verify the stability of communication and the accuracy of data transmission.

Regular maintenance: Regularly inspect and maintain the TU841 module, including cleaning the surface dust of the equipment, checking the connection of communication cables, and checking the operating status indicator lights of the equipment. Regularly backup module configuration data to prevent system malfunction or parameter loss. At the same time, pay attention to ABB's official product update information and maintenance guidelines, promptly perform software upgrades and troubleshooting, and ensure that the equipment is always in good operating condition.


Similar model supplement

ABB TU830: It is also a communication interface module used for S800 I/O systems. Compared with TU841, TU830 mainly supports PROFIBUS DP protocol, which is slightly inferior in the diversity of communication protocols. But it has high stability and reliability in PROFIBUS DP communication, and is suitable for industrial automation systems mainly based on the PROFIBUS DP protocol. Its price is relatively low, making it an economical choice for projects with limited budgets and relatively single communication protocol requirements.

ABB TU850: The communication interface module of this model is more powerful in terms of functionality than TU841. In addition to supporting common protocols such as PROFIBUS DP, Modbus TCP, Ethernet/IP, it also supports some advanced communication protocols and functions, such as PROFINET, OPC UA, etc. It has higher data processing capabilities and faster transmission speeds, making it suitable for complex industrial automation projects that require extremely high communication performance and functionality, such as large smart factories, high-end manufacturing production lines, etc. However, its price is relatively high, and when selecting, it is necessary to consider project requirements and cost budget comprehensively.

  • Sigmatek MDD111-1 DIAS Drive Axis Module
  • Sigmatek DKL042 05-024-042 Terminal Module
  • Sigmatek DM822 Control Module
  • Sigmatek CDM167 12-008-167-O Module
  • Sigmatek TAE151 Touch Display Unit
  • Sigmatek DCC041 SLIDES Module 05-700-041-D
  • Sigmatek AKM65M-ANC2GBB0 PM Servo Motor
  • Sigmatek ETT221 01-230-221 Operator Terminal
  • Sigmatek SLIDES DAM 124 Analog Module
  • Sigmatek AKM31C-ANCNGBB0 Servo Motor
  • Mannesmann Demag Sigmatek CP626 Central Unit
  • SIGMATEK 0332.554.03 Board 371071000154
  • SIGMATEK 12-250-021 Base Plate Back Panel CM5V020
  • SIGMATEK DM162 S-DIAS Digital Mix Module
  • DEMAG ERGOTECH 061 381 66 Sigmatek 9842.243.02 Circuit Board
  • SIGMATEK CP313-1 PLC Module
  • Sigmatek ETV0551-2 VARAN Touch Terminal
  • Sigmatek SDM 081 FS S-Dias Safety Module
  • DEMAG 05-250-023 Ergotech Motherboard with Sigmatek TMS012
  • Sigmatek CM5V020 12-250-023-K Wiring Base
  • Sigma Tek 5000B-37 Attitude Gyro Indicator
  • Sigmatek SDD120-2 DIAS Drive
  • Sigmatek CME221 Memory Module
  • Sigmatek DCP640 DIAS Central Unit
  • Sigmatek STO040 Safety Output Module
  • Sigmatek CET281 Control Panel
  • Sigmatek CIPC LX800 Demag NC5 CPU
  • Sigmatek DKL093 05-024-093 Terminal Module
  • Sigmatek AI088 20-009-088 Analog Input Module
  • Sigmatek CAI888 Analog Input Module
  • SIGMATEK CCA021 12-025-021 Analog Output Module
  • SIGMATEK 1104.579.05 Control Module
  • SIGMATEK SDI100 Digital Input Module
  • SIGMATEK C-IPC 256MB LX800 Compact Dias
  • SIGMATEK 9423.090.02 Control Module
  • SIGMATEK C-IPC 256 Power Supply 148498
  • SIGMATEK CAI025 Analog Input Module
  • SIGMATEK CTO166 Digital Output Module
  • SIGMATEK CP112 20-004-112 Processor Module
  • SIGMATEK CAI887 12-009-887 Safety Module
  • Sigma-Tek 4000B-31 Directional Gyro 1U262-002-42
  • Sigmatek C-IPC 256MB LX800 IPC Controller
  • Sigmatek C-IPC 01-450-031 Industrial PC LX800
  • Sigmatek C-IPC 256 Industrial PC Controller
  • Sigmatek CCP-531 PLC Processor Module
  • Sigmatek CDI163 Digital Input Module
  • Sigmatek ETV0501 VARAN Terminal 12-230-0501
  • Sigmatek CTMS020 C-DIAS Technology Module
  • Sigmatek CIV512 VARAN Switch Module
  • Sigmatek HU011 20-080-011 Interface Module
  • SIGMATEK SLIDES DAM 124 Module
  • SIGMATEK C-IPC 161 01-450-161L Industrial PC
  • SIGMATEK C-IPC 128MB VIA 733MHz 01-450-024-K
  • SIGMATEK 12-780-012 R8-IPC Geode LX800 Module
  • SIGMATEK CAM124 Analog Module
  • SIGMATEK S1 032-8AF61-R4 EZ Servo Motor
  • SIGMATEK CTO163 Digital Output Module
  • SIGMATEK CCP082 12-004-082 Processor Module
  • SIGMATEK CRCH081 C-DIAS Temperature Module
  • SIGMATEK PC322-K 01-310-322-K Industrial PC
  • SIGMATEK SDD310-2 Servo Drive
  • SIGMATEK AI084 Analog Input Module
  • SIGMATEK CRCH081 12-752-081 Temperature Module
  • Sigma-Tek 5000L-4 Attitude Gyro 1U284-001-3
  • SIGMATEK CM5V020 12-250-023-K Wiring Module
  • Sigma-Tek 4000H-6 Directional Gyro IU262-035-7
  • SIGMATEK Dias DCP160 05-004-160 Processor Module
  • SIGMATEK 0147.395.02 Control Module
  • SIGMATEK A1084 Control Module
  • SIGMATEK DI200 20-006-2000 Digital Input Module
  • Sigmatek DNC115 Encoder Module
  • Sigmatek DAM122 05-017-122 Analog Module
  • Sigmatek 9802.289.01 Control Board TA71 Display
  • Sigmatek TO127 20-007-127 Digital Output Module
  • Sigmatek DNC031 05-011-031 Digital Module
  • Sigmatek VI022 20-003-022 Interface Module
  • Sigmatek CAI085 Analog Input Module
  • Sigmatek CP111 S-DIAS CPU Module
  • Sigmatek CTMS030 Krauss Maffei Module
  • Sigmatek CAM123 Control Module
  • Sigmatek TAE732-P 01-240-732-P Touch Display Unit
  • Sigmatek MDM021 Digital Mixed Module
  • Sigmatek DCP642 DIAS Central Unit
  • Sigmatek CST022 12-014-022 C-DIAS Module
  • Sigmatek SRO021 20-893-021 Safety Relay Output
  • Krauss Maffei MC5 Control System Sigmatek
  • Sigmatek DC061 Module 18-24VDC 300mA
  • Herrmann EVT0855 Ultrasonic Welder Touch Panel
  • Sigmatek CIV521 Control Module 1.4A 2W
  • Sigmatek DDI61 05-006-161 Digital Input Module
  • SIGMATEK ETT312-E Touch Terminal 01-230-312
  • Cessna S3326-1 Sigma Tek 5000B-67 Gyro 1U149-015-9
  • SIGMATEK PS101 Power Supply Module
  • SIGMATEK 0332.554.03 Control Module 371071000154
  • SIGMATEK ETT312-E Touch Terminal 01-230-312
  • SIGMATEK CDM163 Control Module
  • SIGMATEK VSV046 16-023-046 Module
  • SIGMATEK AM221 20-017-221 Analog Module
  • SIGMATEK CTS051 12-053-051 Control Module
  • SIGMATEK AM221 20-017-221 Analog Module
  • Sigmatek CSDI161 12-891-161 Safety Input Module
  • Sigma Tek 4000C-1 Directional Gyro Indicator
  • Sigmatek ETV0501 12-230-0501 VARAN Terminal
  • Sigmatek DDM165 SLIDES Module
  • Sigmatek N100 20-011-100 Control Module
  • Sigmatek AKM54K-ANC2R-B0 PM Servo Motor
  • Sigmatek CTO166 Digital Output Module
  • Sigmatek CP212-K 20-004-212-K CPU Module
  • Sigmatek CDI161 Digital Input Module
  • Sigmatek DCC080 05-700-080-2 Control Module
  • SIGMATEK SCP011 S-DIAS Safety CPU
  • SIGMATEK SCP011 S-DIAS Safety CPU
  • SIGMATEK SRO022 Relay Output Module
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK DSI021 SLIDES Siemens Interface
  • SIGMATEK DIAS DCP161 Module 05-004-161
  • Sigmatek ETT312 Built-in Touch Terminal
  • SIGMATEK DCP 643 DIAS Controller System
  • SIGMATEK CIO021 Multi I/O Module
  • SIGMATEK CTMS020 Control Module
  • Sigmatek CME 221 Memory Module
  • Sigmatek 0420.615.01 Control Board
  • Sigmatek CP111 20-004-111 CPU Module
  • Sigmatek 9405.065.03 Control Board
  • Sigmatek ETEK 01-450-032-K C-IPC 256MB Industrial PC
  • Sigmatek CTO163 12-007-163 Safety Output Module
  • Sigmatek TO081 20-007-081 Digital Output Module
  • Sigmatek SI021 20-022-021 Safety Input Module