Bently Nevada 3300 XL 8mm Proximity Sensor System

F: | Au:FAN | DA:2025-09-12 | 668 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Bently Nevada 3300 XL 8mm Proximity Sensor System

Core positioning and composition of the product

1. Core functions

Based on the principle of eddy current induction, a voltage signal proportional to the distance between the probe tip and the conductive surface is output, which can simultaneously measure static position (such as radial/axial position of the shaft) and dynamic vibration (such as vibration of rotating equipment). It also supports Keyphasor signal reference and speed measurement, mainly used for state monitoring of fluid film bearing equipment.

2. System composition

The entire system consists of three parts, and each component supports complete interchangeability without the need for separate matching or bench calibration:

3300 XL 8mm probe: core sensing component responsible for collecting distance signals;

3300 XL extension cable: connects probe and preamplifier, 1-meter system does not require extension cable;

3300 XL Proximitor Sensor: processes probe signals and outputs standard voltage, supporting multiple installation and communication scenarios.

Core advantages of the product

1. High compatibility and interchangeability

Backward compatibility: 3300 XL 8mm components (electrical+physical) can be interchanged with non XL series 3300 5mm/8mm components to adapt to old system upgrades; However, when used in combination, system performance may be limited by the specifications of non XL components.

Flexible adaptation: When the installation space is limited and an 8mm probe cannot be used, it can be replaced with a 3300 series 5mm probe (refer to document 141605); If a narrow side view probe is required, the 3300 NSv system can be used (refer to document 147385).

2. Strong environmental adaptability

Structural durability: The probe adopts patented TipLoc molding technology (the probe tip is more firmly combined with the body), CableLoc design (75lbf/330N tensile strength), 8mm probe coil packaging is thicker, and the resistance to physical damage is stronger;

Protection and anti pollution: FluidLoc cable is optional to prevent oil and other liquids from leaking through the interior of the cable; The preamplifier has high immunity to radio frequency interference (RFI/EMI) and can meet EU CE certification without the need for special shielded conduits;

Wide temperature range and resistance to extreme conditions: Standard probe operating temperature -52~+177 ℃ (-62~+350 ℉), extended temperature range (ETR) probe tip can reach 218 ℃ (425 ℉), ETR cable can reach 260 ℃ (500 ℉), while resisting 50g impact and 30g vibration (10Hz~2kHz).

3. Convenient installation and maintenance

Flexible installation: The preamplifier supports high-density DIN rail installation or traditional panel installation (4-hole installation position compatible with the old model), without the need for additional isolation plates;

Simplified connection: The components use gold-plated ClickLoc connectors, which only require finger tightening (indicated by a "click" when in place), without the need for specialized tools; It is recommended to install a connector protective cover (or use accompanying silicone tape, but not recommended for use in turbine oil environments).


Key technical parameters

1. Electrical performance (standard conditions:+18~+27 ℃, altitude of 2000 meters, -24Vdc power supply, AISI 4140 steel target)

Parameter category specific specifications

Linear range of 0.25~2.3mm (10~90mil), corresponding to output voltage of -1~-17Vdc

Incremental scaling factor (ISF) standard 5/1-meter system: 7.87V/mm (200mV/mil) ± 5%; 9-meter system/ETR system: ± 6.5% (0~45 ℃)

Linear Deviation (DSL) standard 5/1-meter system: ± 0.025mm (± 1mil); 9-meter system/ETR system: ± 0.038mm (± 1.5mil)

Supply voltage -17.5~-26Vdc (with safety barrier -23~-26Vdc), maximum power consumption 12mA

Frequency response 0~10kHz,+0/-3dB (supports up to 305 meters/1000 feet of on-site wiring)

2. Mechanical and physical parameters

Key specifications of components

Probe material: PPS plastic at the tip of the probe, AISI 303/304 stainless steel casing; Cable: 75 Ω three-axis FEP/PFA insulation

Extended cable capacitance 69.9pF/m; 3-meter cable resistance: core wire 0.66 Ω± 0.10 Ω, outer conductor 0.20 Ω± 0.04 Ω

The material of the preamplifier is A308 aluminum; Weight 246g (8.67oz); Installation torque: maximum probe housing 11.2~33.9N · m

The typical total weight of the system is 0.7kg (1.5lb); Probe 323g/m, extension cable 34g/m (with armor 103g/m)


Applicable scenarios and compliance certification

1. Target application areas

Mainly used in industrial scenarios that require monitoring the status of rotating equipment, including:

Energy: Wind turbines;

Heavy industry: steel, aluminum equipment;

Manufacturing: Pressure machines, metal forming equipment;

Special scenarios: testing and simulation systems, chemical equipment, robots.

2. Compliance and Security Certification

Specific standards and levels for certification types

Electromagnetic compatibility (EMC) complies with EN 61000-6-2 (industrial immunity) and EN 61000-6-4 (industrial emissions)

Functional safety SIL 2 (HFT=0), SIL 3 (HFT=1)

ATEX/IECEx hazardous area certification: II 1 G Ex ia IIC T4/T5 Ga (Zone 0), II 3 G Ex nA IIC T4/T5 Gc (Zone 2); cNRTLus:Class I Zone 0/2、Div 2

  • Basler SR32A2B05B3E Static Voltage Regulator
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric 9110000113 Excitation Module
  • Basler Electric 90-72300-114 Control Accessory
  • Basler Electric PRS-250 Protection Relay System
  • Basler Electric BE1-50/51M-109 Overcurrent Relay
  • Basler Electric SR4A1B10B3E Static Voltage Regulator
  • Basler Electric CBS 212 Current Boost System
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric MOC2207 Motor Operated Potentiometer
  • Basler Electric SR4A1B05A3E Static Voltage Regulator
  • Basler Electric BE1-32R Power Relay B2EE1PA0N1F
  • Basler BEI-81 Underfrequency Relay
  • Basler CBS 212A Current Boost System
  • Basler SSR 63-12 Static Voltage Regulator
  • Basler DGC-2020 Digital Genset Controller
  • Basler BE1-32 Reverse Power Relay
  • Basler BE1-50/51B-207 Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler L304KC Protective Relay
  • Basler BE3-25-1S1N4 Time Overcurrent Relay
  • Basler 9032300113 Excitation Support System
  • Basler BE1-59N Ground Overvoltage Relay
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler MOC2102 Potentiometer
  • Basler BE1-87G Generator Differential Relay
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS 125-15-B2C5 Digital Excitation System
  • Basler Electric PLA2400-12GM Power Supply
  • Basler Electric BE1-50/51B-235 Overcurrent Relay
  • Basler Electric BE1-27/59 Undervoltage Overvoltage Relay
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE1-32R Solid State Power Relay
  • Basler Electric BE1-700 Digital Generator Management Relay
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric BE10493002 Protection Module
  • Basler Electric BEI-79A1AA5CA3M1F Digital Annunciator
  • Basler Electric SSR 32-12 Static Voltage Regulator
  • Basler Electric BE1-CDS240 Current Differential System
  • Basler Electric BE1-67 Directional Overcurrent Relay
  • Basler Electric 9121000106 DECS-100 Voltage Controller
  • Basler Electric BEI-871 Interface Module
  • Basler Electric 8650C72 Exciter Control Module
  • Basler Electric RDP-110-S1 Generator Annunciator
  • Basler Electric BE1-32O/U Directional Power Relay
  • Basler Electric BE2000E AVR Voltage Regulator
  • BASLER ELECTRIC BE1-50F2EA1PA0N0F Instantaneous Overcurrent Relay
  • BASLER ELECTRIC BE1-81T1EE1WA0N1F Underfrequency Relay
  • Basler BE1-67 Directional Overcurrent Relay
  • Basler BE1-25/79TR Reclosing Relay
  • Basler CEM-2020 Contact Expansion Module
  • Basler BE1-11 Overcurrent Protection Relay
  • Basler BE1-GPS Generator Protective Relay
  • BASLER ELECTRIC MVC-300 MANUAL VOLTAGE CONTROL UNIT 9121000106
  • Basler Electric KR2FF Voltage Regulator 9 1163 00 109
  • BASLER ELECTRIC BE1-87G-G1E-A1K-A0N0F Generator Differential Relay
  • Basler BE1-47NE3EA1PA0N2F Phase Sequence Relay
  • Basler BE1-81-T1E-E1C-B0N1F Frequency Relay
  • Basler DECS125-15 Excitation Control
  • Basler BE1-25 Sync-Check Relay
  • Basler BE1-50/51B Overcurrent Relay
  • Basler BE1-40Q Loss of Excitation Relay
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler SSE-N 250-9 KW Shunt Exciter Assembly
  • Basler BE1-87T Transformer Differential Relay
  • Basler BE1-60 Solid State Protective Relay
  • Basler DECS125-15 Excitation Control System
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE150BF Overcurrent Relay
  • BASLER ELECTRIC BE1A1HF1JD1S2F Overcurrent Relay
  • Basler BE1-81O Under/Over Frequency Relay
  • Basler EDM-200 Exciter Diode Monitor
  • Basler DECS125-15-B2C5 Excitation Control
  • Basler 9261402100 PCB Board
  • Basler 9252000107 Overcurrent Relay
  • Basler BE1-87T Solid State Protective Relay
  • Basler Electric Phase Directional Overcurrent Relay BE1-Z2JA0N2F
  • Basler SSR125-12 Static Voltage Regulator
  • Basler Electric KR7F VOLTAGE REGULATOR 9116200100
  • BASLER ELECTRIC BE1-59N-A8E-E1L-N0S1F Ground Overvoltage Relay
  • Basler SR8A2B06B3A Static Voltage Regulator
  • BASLER ELECTRIC BE1-81O/UT3EE1KA7N1F Under/Over Frequency Relay
  • Basler MOC2107 Output Module
  • Basler 9125600102 Control Module
  • BASLER ELECTRIC BE1-81T1EE1EA2N0F
  • Basler BE3-25A Time Overcurrent Relay
  • Basler Electric CBS 212 Current Boost System 9 2650 00 100 120/240 VAC 50/60Hz
  • Basler Electric BE1-27 Under Voltage Relay A3EC1JA0N5F
  • Basler BE1-32R Power Relay B2EE1PA0N1F
  • Basler DECS100-B15 Automatic Voltage Regulator
  • Basler SR8A-2B15B3A Static Voltage Regulator
  • Basler AVC63-4 Analog Voltage Regulator
  • Basler UFOV 260 A Overvoltage Module
  • Basler SR4A-2B16B3A Static Voltage Regulator
  • Basler SR4A-2B16B3E Static Voltage Regulator
  • Basler SCA1300-32GM CCD Camera
  • Basler BE34062001 G18 Transformer
  • Basler BE1-87T Transformer Differential Relay
  • Basler 9 2849 00 101 DECS Power Module
  • Basler RAL6144-16GM Line Scan Camera
  • Basler 9269101107 Voltage Regulator Board
  • Basler BE1-851 Overcurrent Relay
  • Basler SR32A-2B13B3E Static Voltage Regulator
  • Basler 9 2007 00 100 Current Boost System CBS 305
  • Basler DECS-100-B11 Automatic Voltage Regulator
  • Basler BE127 Under Voltage Relay
  • Basler 3300C03B1028-G01 Spike Suppressor
  • Basler SSR 125-12 Static Voltage Regulator
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BE32965001 Transformer Timer Kit
  • Basler D90 96801 100 PCB Card
  • Basler BE1-81-T1E-E1C-A0N1F / 9106400 Underfrequency Relay
  • Pro-Face Basler AGP3600-T1-D24 HMI Touch
  • Basler SR4A2B10B1A Static Voltage Regulator
  • Basler SR8A2B05B3A Static Voltage Regulator
  • Basler BE1-25 Time Overcurrent Relay M1FA6PA4S0F
  • Basler SR4A2B05B3E Static Voltage Regulator
  • Basler DECS-200-2L Digital Excitation Control
  • Basler BE303280001 Control Transformer
  • Basler 9262103004 Voltage Regulator Board For Basler DECS-400
  • Basler ICRM-7 Inrush Current Reduction Module
  • Basler BE1-32R Power Relay
  • BASLER ELECTRIC KR4F VOLTAGE REGULATOR 9042600100 600V 50/60Hz
  • Basler 9222600101 Power Module