Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS215VPROH1B VME PROTECTION ASSEMBLY
    ❤ Add to collection
  • GE IS215VPROH1B VME PROTECTION ASSEMBLY

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS215VPROH1B VME PROTECTION ASSEMBLY

    • ¥21587.36
      ¥21587.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:6.380KG
    • Quantity:
    • (Inventory: 39)
Description

GE IS215VPROH1B VME PROTECTION ASSEMBLY


GE IS215VPROH1B VME PROTECTION ASSEMBLY

Part Number IS215VPROH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockThe IS215VPROH1B is a Turbine Protection Board designed for the Mark VI system. The Turbine Protection Board (VPRO) and its associated terminal boards (TPRO and TREG) provide an independent emergency overspeed protection system. 

The protection system consists of three redundant VPRO boards in a module separate from the turbine control system, which control the trip solenoids via TREG. VPRO also has an Ethernet connection for IONet communications with the control modules. FUNCTIONAL DESCRIPTION The VPRO board in Protection Module P performs the emergency trip function. Up to three trip solenoids can be connected between the TREG and TRPG terminal boards TREG supplies the positive side of the 125 V dc to the solenoids, while TRPG supplies the negative side. Either board has the ability to trip the turbine. VPRO offers emergency Overspeed protection as well as emergency stop functions. It is in charge of TREG's 12 relays, nine of which form three groups of three to control the three trip solenoids. VPROH1A has been replaced by the functionally equivalent VPROH1B. 

VPROH1A and VPROH1B support a second TREG board that is powered by VPRO connector J4. IS215VPROH1B Installation To install the VPRO board Turn off the VME I/O processor rack. Insert the VPRO board and use your hands to push the top and bottom levers in to seat the edge connectors. Tighten the captive screws on the front panel's top and bottom. Power up the VME rack and check the diagnostic lights at the top of the front panel Cable connections to the TPRO and TREG terminal boards are made at the VPRO front panel connectors J3, J4, J5, and J6. To secure the cables, these are latching connectors. J7 is a 125 V dc power connector. 

Refer to the section on diagnostics in this document for more information. You may need to update the VPRO firmware to the most recent version. IS215VPROH1B Operation The main purpose of the protection module is to protect the turbine from emergency overspeed (EOS) using three VPRO boards. VPRO also has backup synchronization check protection, three analog current inputs, and nine thermocouple inputs, which are primarily intended for gas turbine exhaust over-temperature protection. 

With three completely separate and independent VPRO boards named R8, S8, and T8, the protection module is always triple redundant (originally named X, Y, and Z). While the turbine is running, any of these boards can be powered down and replaced without jeopardizing the protection system. Each board has its own I/O interface, processor, power supply, and Ethernet communications to the controller (IONet). The communications allow the controller to send test commands to the protection module and monitor EOS system diagnostics in the controller and on the operator interface. The VPRO board, which serves as the system's heart, is where communications take place. The VPRO board has a VME interface for programming and testing in a VME rack; however, when plugged into the protection module, the backplane is neutralized, removing any continuity between the three independent sections. 

 Speed Control and Overspeed Protection Six passive, magnetic speed pickups are used to implement speed control and overspeed protection. The controllers monitor the first three, which use the median signal for speed control and primary overspeed protection. The second three are connected to the R8, S8, and T8 VPROs in the protection module separately. On the TPRO terminal board, nine passive magnetic speed pickups or active pulse rate transducers (TTL type) are provided, with three monitored by each of the R8, S8, and T8 VPROs. The application software has separate overspeed trip settings for the primary and emergency overspeed trip limits, and a second emergency overspeed trip limit must be programmed into the I/O configurator to confirm the EOS trip point. Interface To Trip Solenoids The trip system combines the controller's Primary Trip Interface with the protection module's EOS Trip Interface. 

To interface with the hydraulics, three separate, triple redundant trip solenoids (also known as Electrical Trip Devices - ETDs) are used. The TRPG and TREG terminal boards are linked by the ETDs. From the turbine control, a separately fused 125 V dc feeder is provided for each solenoid, which energizes in the run mode and de-energizes in the trip mode. Backup Synch Check Protection The Protection Module includes backup synch check protection. The generator and bus voltages are supplied by two single-phase potential transformers (PTs) with secondary outputs of 115 V rms. Between the PTs and the turbine control, the maximum cable length is 100 meters of 18 AWG twisted, shielded wire. Each PT is magnetically isolated, with a rated barrier of 1,500 V rms and a circuit load of less than 3 VA. Synchronization algorithms are based on phase lock loop techniques. At nominal voltage and 50/60 Hz, the phase error between the generator and bus voltages is less than +/-1 degree. 

The measured frequency is within 0.05% of the input frequency and supports a frequency range of 45 to 66 Hz. Diagnostics Three LEDs at the top of the VPRO front panel indicate status. The normal RUN condition is a flashing green, while the FAIL condition is a solid red. The third LED is STATUS, which is normally off but displays a steady orange if the board has a diagnostic alarm condition. VPRO performs diagnostic checks and generates faults in the following ways: Feedback from the trip relay driver and contacts Solenoid voltage and source of solenoid voltage Economizer relay driver and contact feedbacks Relay driver and coil K25A Contact feedback and servo clamp relay driver All analog inputs have high and low limits. 

If any of the above signals fails, a composite diagnostic alarm L3DIAG VPROR, S, or T is generated. Individual diagnostic signals can be latched and then reset with the RESET DIA signal if they become healthy. Features The Board protects against backup synch checks and detects speed differences. The thermocouple and analog inputs are both supported by the board. Two circuit boards are stacked one on top of the other in this module. The top board, an IS200VPRW, is inserted into standoffs and connects to the lower board by four screw connections. Integrated circuits, a transformer, multiple transistors, as well as resistors, capacitors, and diodes, are all present on the board. Carbon composite material is sometimes used to make resistors. There are various inductor coils on the board, as well as numerous connectors, including plugs. 

A heat sink can be found on the right front side. The module's bottom board has two backplanes. There are capacitors and resistors, as well as many integrated circuits, in it. Oscillating chips are included in this category. The top board's standoffs are set towards the board's margins. The module uses the TREG board to regulate trip solenoids. The controller's application software is used to start tests on these trip solenoids. These can also be tripped manually. A faceplate is included with the board. LED indicators, a power switch, cable connectors, and Ethernet connectors are all found on the faceplate. Screws attach this faceplate to the boards.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured