Safety-related Precautions

Operation in Hazardous Environments: This module is suitable for use in certain hazardous locations (Class I Division 2 Groups A, B, C, D and non-hazardous locations). When operating in these environments, be sure to disconnect the power or confirm that the area is safe before connecting, disconnecting, or replacing the components, otherwise serious accidents, such as explosions, may occur.

Static electricity protection: The module is sensitive to static electricity. When operating, touch a grounded object to discharge static electricity, wear a grounded wrist strap, and avoid touching connectors, pins, and internal circuit components. When conditions permit, use an electrostatic safe workstation and store the equipment in an anti-static package when not in use.


Electrical Safety: Plugging and unplugging a module under power can cause an electric arc that not only damages the module and connectors, but can also cause an explosion in a hazardous location. Therefore, when installing or removing a module in a hazardous location, make sure that the power is off or that the area is free of hazards. Also, be sure that the module relay terminals are powered in compliance with UL and CE standards and that the line voltage of the external DC power supply is the same as the power supply powering the SRM chassis.


Installation and Equipment Requirements

Environmental conditions: This equipment is intended for use in industrial environments in pollution degree 2, overvoltage category II applications at altitudes up to 2000 metres above sea level. Use in other environments may present electromagnetic compatibility problems. The device is open and needs to be installed in a suitable enclosure that is flame retardant, has a protection rating of at least IP54 (in Class I, Zone 2 environments) and has internal live parts that are accessible with tools.

Equipment compatibility: The redundant system components must be identical, including the order of the primary and secondary control chassis and their internal modules, as well as the firmware versions of all modules. Otherwise, the 1757-SRM module will not allow the secondary chassis to mate with the primary chassis.


Installation Procedure Considerations

Pre-installation: Before installation, familiarise yourself with the operation of the module and learn about the redundancy system and redundancy media. Prepare the required components, such as the specific chassis, power supply, and fibre optic cables, and follow the appropriate installation instructions for installing and connecting the ControlLogix chassis and power supply. Determine the module mounting slots in the chassis; different chassis models have different recommended slots.

Installation Procedure: When connecting the fiber optic cable, connect one end to the module's fiber optic port before installing the module . When mounting the module, ensure that the board is aligned with the chassis guides and slide in smoothly so that it is flush with the other mounting modules. If a user relay is used, connect the wires to the detachable terminal block after passing them through the ferrite core and plug them into the relay terminals, taking care to operate with the power off to avoid arcing.


System Configuration and Upgrade: After assembling the chassis, specify the primary chassis and qualify the system to ensure that all module pairs have compatible firmware versions. Before specifying a primary chassis, flash upgrade the factory boot firmware of the 1757-SRM module. When upgrading the module firmware, the programmes and data in the device should be backed up, as the upgrade will overwrite the original data.

IMPORTANT INFORMATION AND SAFETY NOTICE: Solid-state devices have different characteristics than electromechanical devices. Ensure that the application meets the requirements before using the device and Rockwell Automation will not be responsible for consequential damages. Document examples are for reference only and may not be reproduced without permission. The manual contains a variety of cautionary statements to alert the user to the dangers of explosion, static electricity, electric shock, and burns, as well as the potential for damage to equipment and injury or death from mishandling. This equipment is intended for use in specific hazardous locations and is to be operated and maintained in accordance with relevant safety regulations, such as operating without power and using qualified components.


Module Overview and Preparation for Installation: 1757 - SRM Series B Modules for ProcessLogix or ControlLogix Redundant Chassis Pairs require knowledge of module operation, redundancy systems, and protection against static electricity prior to installation. Prior to installation, prepare the required components, install and connect the ControlLogix chassis and power supply, identify the module mounting slots, and match the redundant system components, including the chassis and module firmware versions.


Installation and Usage: To assemble the redundant system, assemble two identical chassis, connect the fibre optic cables, and install the modules, taking care to avoid energising the system during installation. If a user relay is used, it must be wired to a detachable terminal block and plugged into the relay terminals. Modules can be installed or removed under power but at some risk. Modules can be reset by cycling power to the chassis or by plugging or unplugging the module. To remove a module, follow the specific procedure and replace the module in its original slot.


Module Status and Troubleshooting: The module has a variety of status indicators, such as module status, health status, communication status and chassis status indicators, which indicate the module's operating status and fault conditions through different displays and colours. Faults are classified into four categories and recorded in the event log, which can be viewed through the module's four-character status display, and corresponding measures, such as reset and replacement of the module, are taken according to different fault types.


Specification and certification information: The module has specific specifications in terms of electrical, physical and environmental aspects, including backplane current, size, weight, mounting method, temperature code, power requirements, insulation resistance, etc . A variety of certifications, such as UL, CSA, FM, CE, etc., are available to comply with relevant standards for use in different regions and environments.

Resources and Contacts: Technical documentation resources are available for review and download on our website, or in paper form by contacting your local distributor or sales representative Rockwell Automation provides web-based and telephone support, and product returns and exchanges are available in accordance with established procedures.

ALLEN BRADLEY 1757-SRM ProcessLogix System Redundancy Module at ₹ 26880 ...

  • Basler Electric 9289902106 Circuit Board
  • Basler Electric BE1-32R Protective Relay A1E E1P BOS1P
  • Basler Electric RAL6144-16GM GigE Line Scan Camera with Lens
  • Basler Electric BE3-49R-5I5A1 Temperature Relay
  • Basler Electric BE1-32R Power Relay B3E E1R A0N1F
  • Basler Electric SR4A2B06B3A Static Voltage Regulator Features
  • Basler Electric 9121000106 Manual Voltage Control MVC Guide
  • Basler Electric SR32A-2B15B3E Static Voltage Regulator
  • Basler Electric SR4A2B06B3A Static Voltage Regulator Guide
  • Basler Electric 801A193F02 Hammond Transformer Module
  • Basler Electric BE1-24 Volts Per Hertz Relay A1E F1J D1S0F
  • Basler Electric AEC63-7 Analog Excitation Controller 220-277V
  • Basler Electric BE132R Power Relay T245579
  • Basler Electric MVC 108 Manual Voltage Control 90 37000 102
  • Basler Electric 9022900-103 Control Transformer 6-7VA 60Hz
  • Basler Electric BE1-79M Plug Adapter 9170111102
  • Basler Electric 9 2007 00 100 Current Boost System CBS 305
  • Basler Electric SR4A2B01B3A Static Voltage Regulator 120V
  • Basler Electric BE1-32R Power Solid State Relay E2E A10 A0N0F
  • Basler Electric PRS250 Veri-Sync Relay 9088800102
  • Basler DECS 125-15-B2C Digital Excitation Control
  • Basler BE 13693 002 Transformer
  • Basler BE1-59N Ground Fault Overvoltage Relay
  • Basler BE1-79A Reclosing Relay
  • Basler 9-1051-00-105 Overload Protection Module
  • Basler BE1-32R Power Relay – Directional Overcurrent Guide
  • Basler 9319700103 BE3-27T/59T-3A1N3 Voltage Relay
  • Basler BE1-87G Generator Differential Relay
  • Basler BE3-25-1D1N4 9319100106 480V Relay
  • Basler SR8A2B07B3A Static Voltage Regulator
  • Basler Electric BE4-27/59 Over/Under Voltage Relay 307-2552
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric BE1-27 A3E C3J A1N6F Solid State Protective Relay
  • Basler Electric 9174700-100 Excitation Limiter Generator
  • Basler Electric BE1-87G Generator Differential Relay 09833
  • Basler Electric 9310200100 Power Supply Module
  • Basler Electric TIEE1CD0N07 Control Module
  • Basler Electric BE1-59N Ground Fault Relay T214750
  • Basler Electric SR8A2B10B3AX Static Voltage Regulator 9060200126
  • Basler Electric SSR 125-12 Voltage Regulator
  • Rolls Royce H1111.0204 Ship Main Controller
  • Basler Electric BE3-32-3AC Reverse Power Relay 9 1376 00 105
  • Basler Electric BE3-25-1A1N4 Synch Check Relay 9319100100
  • Basler Electric SR4A-2B15B3A Static Voltage Regulator
  • Basler Electric SR4A-2B15B3E Static Voltage Regulator
  • Basler Electric 9170818100 Solid State Protective Relay
  • Basler Electric AEC63-7 Analog Excitation Controller
  • Basler Electric 17483 Auxiliary Module
  • Basler Electric BE1-59 Over Voltage Relay
  • Basler Electric 21600-101 Control Module
  • Basler Electric KR2F Generator Voltage Regulator 9056600100
  • Basler BE1-CDS Current Differential System
  • Basler Electric CBS 212 Current Boost System 9 2650 00 100
  • Basler Electric IFM-150 Firing Circuit Chassis
  • Basler Electric BE1-60 Voltage Balance Relay C1F A1P D0C3F
  • Basler Electric BE1-32R Power Relay A2E D1R A0N0F
  • Basler Electric BE1-32R Power Relay A2E D1R A0N0F
  • Basler Electric 8650C80G01 Isolation Transducer PCB Board
  • ETEL EA-P2M-300-4/7.5A-0100-01 AccurET Modular 300 Servo Drive
  • Basler Electric 87T Transformer Differential Relay
  • Basler Electric BE-6868 Power Transformer 5950007559202
  • Basler Electric PRS250 Veri-Sync Relay 9088800102
  • Basler Electric SCP-250-G-60 VAR Power Factor Controller
  • Basler DECS-150 AVR 1NS2V1N1S Voltage Regulator
  • Basler UFOV 260A Under Frequency Overvoltage Module
  • Basler MOC2 199 Motor Operated Control – Overview and Setup
  • Basler BE3-49R-5K5A1 Temperature Relay – Complete Guide
  • Basler BE 20035 001 Transformer – Technical Data and Installation
  • Basler BE 02727 001 Transformer – Specifications and Usage
  • Basler BE127 Under Voltage Relay – Features and Application Guide
  • Basler CBS377 Current Boost System – Complete Technical Guide
  • Basler BE1-87G P/N 9170818100 Differential Relay – In-Depth Specs
  • Basler BE1-87G Generator Differential Relay – Technical Overview
  • Basler Electric SR4A2B16 SVR Static Voltage Regulator – Complete Guide
  • Basler Electric 9261500101 Power Supply Module
  • Basler Electric AEM-2020 Analog Expansion Module
  • Basler Electric DGC-2020 Digital Genset Controller 51BRBNEAH001
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric BE1-59N-A5E-E1L-N0S1F Neutral Overvoltage Relay
  • Basler Electric MOC2499 Motor Operator Control Potentiometer 9072300430
  • Basler Electric BE1-50/51M Overcurrent Relay
  • Basler Electric 9148100106 MOC3502 Solid State Relay 250VDC 0.25A
  • Basler Electric CBS 212 Current Boost System 9265000100
  • Basler Electric 10493002 Control Module
  • Basler BE1-32R D3E E1R A0N1F Power Relay
  • Basler SR8A2B15B3A Static Voltage Regulator
  • Basler IFM-105 Firing Circuit Chassis 9324100105
  • Basler SR4A2B05B3A Static Voltage Regulator
  • Basler BE151G1EB6PB0N0F Protective Relay
  • Basler BE1-59 Electric Over Voltage Relay
  • Basler 277 Static Programmable Powerline Carrier Channel
  • Basler BE1-32R D1E A1P A0N1F Power Relay
  • Basler SR4A1B07B3A Static Voltage Regulator
  • Basler Electric BE1-700 Digital Protective Relay
  • Basler Electric SR8A-2B01B3A Static Voltage Regulator
  • Basler Electric SR4A-2B01B3E Static Voltage Regulator
  • Basler Electric 9017709102 PC Board
  • Basler Electric SR4A-2B01B3A Static Voltage Regulator
  • Basler Electric PRS-250 Veri-Sync Relay
  • Basler Electric 9066800102 Excitation Support System
  • Basler Electric BE1-87G Generator Differential Relay 9 1708 18 100
  • Basler Electric 36T865-2 BE03752001 Power Supply
  • Basler Electric M-300 149D940G02 Power Supply
  • Basler Electric ACA2040-25GM 4Mp 25Fps Area Scan Camera
  • Basler BE1-87G-S1A-A1C-A0N0 Differential Relay
  • Basler SR8A-2B06B3E Static Regulator SR8A2B06B3E
  • Basler SCP-210 Frequency Controller 9095400100
  • Basler BE1-59-A3E-A1J-N1N3F Overvoltage Relay BE159A3EA1JN1N3F
  • Basler 9 2011 11 100 Bracket Mounted Terminal Unit
  • Basler 9 1606 00 101 Voltage Regulator
  • Basler CBS-377 Current Boost System 9109600102
  • Basler 8650C72 Exciter Control Module PCB Rev 5
  • Basler C2EE1PA0N1F BE1-32R Reverse Power Relay
  • ADLINK HPCI-14S12U - Industrial Control Backplane 12PCI Backplane PCI-14S Passive Backplane
  • ADLINK PCIe-GIE74C - image acquisition card 4-CH GigE Vision PoE+ Frame Grabber
  • ADLINK PCI-8164 - control card 4-Axis Advanced Motion Controller Board
  • ADLINK PCIe-U304 - 4 Port USB3 PCIe Frame Grabbers USB Screw Hole Card
  • ADLINK PCI-9112 - Multi-Function Data Acquisition Card DAQ Card
  • ADLINK PCI-7432 - 51-12013-0A50 4-CH Isolated Numérique I/O PCI Cartes Digital I/O Card
  • ADLINK PCA-6106P3-0C1 REV.C1 - backplane 6-Slot Passive Backplane Board
  • ADLINK PCI-7224 - 24-CH Opto-Isolated Digital I/O PCI Board
  • ADLINK CPCI-7433R(G) - Digital Input Board Rear I/O CompactPCI Card
  • ADLINK EBP-13E4 - 51-46703-0A30 Industrial PC Backplane Passive Backplane
  • ADLINK PCIE-HDV62 - Image acquisition card High Definition Video Frame Grabber
  • ADLINK EBP-13E4 - 51-46703-0A30 Industrial Backplane Board Passive Backplane
  • ADLINK 90111-B1 / CPCI-6770 - PCB CPU MODULE CompactPCI Single Board Computer
  • ADLINK PCI-7248 - DATA ACQUISITION PCI CARD 48-CH Parallel Digital I/O Board
  • ADLINK PCI-7230 - 51-12003-0a50 board PCI7230 32-CH Isolated Digital I/O Card