-Protection level (according to EN60529): enclosure IP20, terminal IP20
-Protection level: Level II
Power consumption - DC voltage (UH=UHN, typical value): 3W
-AC voltage (UH=UHN, typical value): 3.5VA
Internal fuse cannot be replaced, 1.25AT
Status display: 1 green working LED (RUN)
RS232 connection - Connection method: 9-pin sub-D socket
-Maximum baud rate: 115200 baud
-Minimum baud rate: 1200 baud
Optical interface - optical input/output: 1 transmitter, 1 receiver, factory state: light off when idle; Transmitter ST: HFBR 1404; Receiver ST: HFBR 2402
-Optical connection: ST (plastic protective cover)
-Data display: None
-Wavelength: 820nm
-Transmission power: 50/125 μ m multimode fiber: -19dBm; 200 μ m HCS fiber: -6.2dBm
-Sensitivity: -30dBm
-Light budget: 10dB (+3dB system budget)
-Maximum transmission distance: 625/125 μ m fiber optic 3km
-Maximum baud rate: 115200 baud (recommended for fiber optic connections); Approximately 2.5mA at 1200 baud
2 binary inputs - Connection method: 2-pole connector Phoenix, isolated
-Switching voltage: 24-250V DC (-15%,+20%)
-Power consumption (voltage independent): approximately 2.5mA
-Status display: 1 yellow LED per input (BI-1, BI-2)
2 instruction outputs (relays) - Relay type: MSR relay (K1, K2), 1 floating normally open relay
-Connection method: 2-pole terminal Phoenix
-Switching voltage (rated voltage): 250V AC/DC
-Switch capacity: 5A (long-term); 30A (0.5s, if the relay displays); 50-270W (depending on voltage), each 1000VA
-Switching current: Long term 1A
-Status display: 1 yellow LED (K1, K2)
-Fiber optic operation response time (from binary input event of transmitter A to binary output response of transmitter B): 1200 baud 118ms, 2400 baud 63ms, 4800 baud 34ms, 9600 baud 20ms, 19200 baud 17ms, 38400 baud 15ms, 57600 baud 14ms, 115200 baud 12ms (recommended for direct fiber optic connection)
-Response time for modem operation (MT2843BLG modem) (binary signal event from transmitter A to binary signal response from transmitter B): 9600 baud 102ms, 19200 baud 71ms
1 fault indicator output relay - connection method: 2-pole terminal Phoenix
-Switching voltage (rated voltage): 250V AC/DC
-Switch capacity: 30W/VA
-Switching current: Long term 1A
-Fault indicator: No specific parameters
Safety (according to DIN EN 61010 Part 1) - Overvoltage category: Class III (3.7kVAC/5.2kVDC)
-Pollution level: Level 2
-Fire rating (according to UL 94): V0 level
Dielectric Loss Test (EN61010) - Power to Relay to Binary Input: 3.1kV DC/1s (with bypass capacitor)
-Power supply to RS232: 2.0kV AC/50Hz/1s (without bypass capacitor)
-RS232 to relay to binary input: 2.0kV AC/50Hz/1s (without bypass capacitor)
Electromagnetic compatibility test - Electromagnetic immunity test: EN 50082-2
-Electromagnetic emission test: EN 50081-1
Permissible environmental conditions - Operating temperature: -5 ° C to+55 ° C
-Storage temperature with factory packaging: -25 ° C to+70 ° C
-Transportation temperature with factory packaging: -25 ° C to+70 ° C
-Humidity: 10% -93% (no condensation allowed)
-Air pressure: 0-3000 ASL

Functional Unit Description
(1) Overall structure
The signal converter inside the casing is a hard wired and functionally tested unit, equipped with snap on mounting components for DIN EN 50022 35mm top cap rails; The auxiliary power supply can be safely connected through screw terminals; Fiber channel is adapted through ST terminals; The RS232 interface is connected through a 9-pin sub-D socket; The device does not contain silicone and halogens, and has flame retardancy.
(2) Terminal position and allocation
The terminal positions have a specific layout (see Figure 3), and each pin has a clear meaning and abbreviation, as follows:
|Pin | Meaning | Abbreviation|
|L+| Power supply L+| AC: L1; DC:L+|
|L - | Power supply L - | AC: N; DC:L-|
|Pin 1 | Fault signal relay contact M1 | 1 (normally closed contact)|
|Pin 2 | Fault signal relay contact M1 | 2 (normally closed contact)|
|Pin 3 | Command relay K1 | 3 (normally open contact)|
|Pin 4 | Command relay K1 | 4 (normally open contact)|
|5- Pin | Binary Input 1- | BI-1-|
|6+pins | Binary input 1+| BI-1+|
|7- Pin | Binary Input 2- | BI-2-|
|8+pins | Binary input 2+| BI-2+|
|Pin 9 | Command relay K2 | 9 (normally open contact)|
|Pin 10 | Command relay K2 | 10 (normally open contact)|
(3) Switch position and RS232 interface
DIP switch operation: DIP switches can be operated from the outside and have specific position layouts (see Figure 4).
RS232 interface (9-pin sub-D socket): Each pin has a clear description, abbreviation, and direction as DTE, as follows:
|Pin | Description | Abbreviation | Direction as DTE|
| ---- | ---- | ---- | ---- |
|1 | None | None | No connection|
|2 | Receive data | RxD | Input (←)|
|3 | Send Data | TxD | Output (→)|
|4 | None | None | No connection|
|5 | Signal Ground | GND|-|
|6 | None | None|-|
|7 | Signal Ground | GND|-|
|8 | Activity Interface Selection | Bridge | Input|
|9 | None | None|-|
Interface selection instructions:
|Connection status | Interface status | Remarks|
|Not connected | Fiber optic connection activated | Pin 8 open circuit, factory set to fiber optic connection|
|Bridge | RS232 connection activation | Bridge pins 8-7 at the input of the converter|