General

The Panel 800 operator pane lis developed to satisfy the demands of humanmachine communication. 

Built-in functions such as displaying and controlling text,dynamic indication, time channels, alarm and recipe handling are included.

The operator panel work, for the most part, in an object-oriented way, making it easy to understand and use. 

The configuration operation of the panel is made in a personal computer, using the configuration tool Panel Builder 800. 

The project is then transferred and stored in the operator panel.

The operator panel can be connected to many types of automation equipment, such as PLCs, servos or drives. 


Safety Precautions

Operating environment: Suitable for Class I, Division 2, Groups A, B, C, D or non-hazardous locations, with an upper ambient temperature limit of 40°C 

when installed horizontally and 50°C when installed vertically.

Operation: There are safety requirements for installation, use, maintenance and dismantling processes, such as prohibiting operation in hazardous environments, allowing only qualified personnel to operate, and replacing batteries in non-hazardous areas.


Installation Guide

Preparation for installation: 

The thickness of the mounting plate is required to be 1.5 - 9.0mm, and a certain amount of space needs to be reserved around the panel during installation. 

The installation process involves checking the unit, cutting the opening, fixing the panel and connecting the cables, paying attention to electrical earthing, cable type and voltage polarity when making connections.

Mode switches: 

There are four mode switches on the back of the panel, which should normally be in the OFF position and only be operated by qualified personnel. 

Different combinations of switches correspond to different functions, such as operating mode, system recovery, image loading, service menu and self-test.

Module Installation: 

Internal Compact Flash memory card can be installed to expand project memory, power failure is required for installation; 

Profibus DP expansion module can also be installed, check the device and pay attention to static protection before installation.

CB810 - USB to Ethernet Adapter for project-specific transmissions, connectivity and usage restrictions apply.


Technical Data

1. Dimensions and weight

Panel size: The front panel measures 285 x 177 x 6mm. 

This compact design allows it to fit into a wide range of spaces when installed, and for industrial control cabinets or operator consoles where space is limited, 

the PP836's dimensions do not take up too much space, making it easy to integrate with other equipment.

Installation depth: 56mm, or 156mm if clearance is included. In the actual installation process, this figure determines the depth of the device 

in the installation space, users need to ensure that there is enough depth to accommodate 

the PP836 according to the specific dimensions of the installation location to ensure the stability and safety of the device installation.

Weight: 

The weight of the device is 1.4kg, which makes the device more convenient to carry and install, reduces the labour intensity of the installer, and also facilitates the use of the device in some occasions with strict requirements on the weight of the device.


2.Protection level

Front Panel Protection Rating: 

The front panel has a protection rating of IP66, which means it has excellent dustproof and waterproof capabilities.

In dusty industrial environments, such as mines and cement factories, it can effectively prevent dust from entering 

the equipment and avoid circuit failures due to dust accumulation; in environments that may come into contact with water, 

such as food processing workshops and outdoor equipment control scenarios, 

it can prevent water intrusion and ensure the stable operation of the equipment.

Rear panel protection level: 

The rear panel protection level is IP20, which is mainly used to prevent larger objects from entering the device, 

and provide basic protection for the circuit and components inside the device.


3. Interface types and parameters

Serial Interface: 

The RS422/RS485 serial interface is a 25 - pin D - sub contact, chassis - mounted female interface with standard locking screws 4 - 40 UNC. 

This interface is suitable for industrial field serial communication, can be connected to a variety of devices that support RS422/RS485 protocol,

 such as sensors, actuators, etc., to achieve reliable data transmission.RS232C serial port is a 9 - pin D - sub contact, 

male interface, also equipped with a standard locking screw 4 - 40 UNC, commonly used to connect computers, debugging equipment, etc., for close range low-speed data transmission. The RS232C serial port is a 9-pin D-sub contact male interface, also with a standard locking screw 4 - 40 UNC.

Ethernet port: 

The Ethernet interface is Shielded RJ 45, which supports high-speed network communication and can meet the demand for large data 

transmission between the device and other network devices, such as data interaction with servers and other controllers in 

the factory automation system to achieve remote monitoring, data sharing and other functions.

USB port: 

Host type A (USB 1.1) and Device type B (USB 1.1) interfaces are available, of which the maximum output current of Host type A interface is 500mA. 

Users can connect external storage devices, such as USB flash drives, through the USB interface to facilitate data backup and transfer, 

and can also connect USB keyboards, mice and other devices to enhance the ease of operation of the device.

CF card slot: supports Compact flash type I and II memory cards, which can be used to expand the storage capacity 

of the device to meet the user's needs for project memory expansion, such as storing a large amount of historical data, configuration files and so on.


4. Storage and Clock

Application Flash: 

The device has 12MB of application flash memory (incl. fonts), which is used to store application programs and related data to provide 

the necessary software support for the normal operation of the device. 

In practical applications, this storage space can be used to store the device's control programme, interface display data, etc..

Real-time clock: 

The real-time clock has an accuracy of ±20 PPM and is subject to errors due to ambient temperature and supply voltage,

with a total maximum error of 1 min/month at 25°C and a temperature coefficient of -0.034±0.006 ppm/°C². 

Real-time clocks are essential for recording information such as the time of operation of equipment, the time of events, etc. 

In industrial production processes, accurate time recording helps to monitor and analyse the production process and trace the root cause of problems.


5. Power supply related parameters

Power supply voltage: the power supply is + 24V DC, the operating voltage range is 20 - 30V DC, 

this wider voltage range makes the device can adapt to different power supply environment, improve the applicability of the device. 

In some industrial sites, the power supply voltage may have certain fluctuations, 

PP836 can work stably in this voltage range to ensure the normal operation of the equipment.


  • Basler Electric 9121000106 Manual Voltage Control MVC Guide
  • Basler Electric SR32A-2B15B3E Static Voltage Regulator
  • Basler Electric SR4A2B06B3A Static Voltage Regulator Guide
  • Basler Electric 801A193F02 Hammond Transformer Module
  • Basler Electric BE1-24 Volts Per Hertz Relay A1E F1J D1S0F
  • Basler Electric AEC63-7 Analog Excitation Controller 220-277V
  • Basler Electric BE132R Power Relay T245579
  • Basler Electric MVC 108 Manual Voltage Control 90 37000 102
  • Basler Electric 9022900-103 Control Transformer 6-7VA 60Hz
  • Basler Electric BE1-79M Plug Adapter 9170111102
  • Basler Electric 9 2007 00 100 Current Boost System CBS 305
  • Basler Electric SR4A2B01B3A Static Voltage Regulator 120V
  • Basler Electric BE1-32R Power Solid State Relay E2E A10 A0N0F
  • Basler Electric PRS250 Veri-Sync Relay 9088800102
  • Basler DECS 125-15-B2C Digital Excitation Control
  • Basler BE 13693 002 Transformer
  • Basler BE1-59N Ground Fault Overvoltage Relay
  • Basler BE1-79A Reclosing Relay
  • Basler 9-1051-00-105 Overload Protection Module
  • Basler BE1-32R Power Relay – Directional Overcurrent Guide
  • Basler 9319700103 BE3-27T/59T-3A1N3 Voltage Relay
  • Basler BE1-87G Generator Differential Relay
  • Basler BE3-25-1D1N4 9319100106 480V Relay
  • Basler SR8A2B07B3A Static Voltage Regulator
  • Basler Electric BE4-27/59 Over/Under Voltage Relay 307-2552
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric BE1-27 A3E C3J A1N6F Solid State Protective Relay
  • Basler Electric 9174700-100 Excitation Limiter Generator
  • Basler Electric BE1-87G Generator Differential Relay 09833
  • Basler Electric 9310200100 Power Supply Module
  • Basler Electric TIEE1CD0N07 Control Module
  • Basler Electric BE1-59N Ground Fault Relay T214750
  • Basler Electric SR8A2B10B3AX Static Voltage Regulator 9060200126
  • Basler Electric SSR 125-12 Voltage Regulator
  • Rolls Royce H1111.0204 Ship Main Controller
  • Basler Electric BE3-32-3AC Reverse Power Relay 9 1376 00 105
  • Basler Electric BE3-25-1A1N4 Synch Check Relay 9319100100
  • Basler Electric SR4A-2B15B3A Static Voltage Regulator
  • Basler Electric SR4A-2B15B3E Static Voltage Regulator
  • Basler Electric 9170818100 Solid State Protective Relay
  • Basler Electric AEC63-7 Analog Excitation Controller
  • Basler Electric 17483 Auxiliary Module
  • Basler Electric BE1-59 Over Voltage Relay
  • Basler Electric 21600-101 Control Module
  • Basler Electric KR2F Generator Voltage Regulator 9056600100
  • Basler BE1-CDS Current Differential System
  • Basler Electric CBS 212 Current Boost System 9 2650 00 100
  • Basler Electric IFM-150 Firing Circuit Chassis
  • Basler Electric BE1-60 Voltage Balance Relay C1F A1P D0C3F
  • Basler Electric BE1-32R Power Relay A2E D1R A0N0F
  • Basler Electric BE1-32R Power Relay A2E D1R A0N0F
  • Basler Electric 8650C80G01 Isolation Transducer PCB Board
  • ETEL EA-P2M-300-4/7.5A-0100-01 AccurET Modular 300 Servo Drive
  • Basler Electric 87T Transformer Differential Relay
  • Basler Electric BE-6868 Power Transformer 5950007559202
  • Basler Electric PRS250 Veri-Sync Relay 9088800102
  • Basler Electric SCP-250-G-60 VAR Power Factor Controller
  • Basler DECS-150 AVR 1NS2V1N1S Voltage Regulator
  • Basler UFOV 260A Under Frequency Overvoltage Module
  • Basler MOC2 199 Motor Operated Control – Overview and Setup
  • Basler BE3-49R-5K5A1 Temperature Relay – Complete Guide
  • Basler BE 20035 001 Transformer – Technical Data and Installation
  • Basler BE 02727 001 Transformer – Specifications and Usage
  • Basler BE127 Under Voltage Relay – Features and Application Guide
  • Basler CBS377 Current Boost System – Complete Technical Guide
  • Basler BE1-87G P/N 9170818100 Differential Relay – In-Depth Specs
  • Basler BE1-87G Generator Differential Relay – Technical Overview
  • Basler Electric SR4A2B16 SVR Static Voltage Regulator – Complete Guide
  • Basler Electric 9261500101 Power Supply Module
  • Basler Electric AEM-2020 Analog Expansion Module
  • Basler Electric DGC-2020 Digital Genset Controller 51BRBNEAH001
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric BE1-59N-A5E-E1L-N0S1F Neutral Overvoltage Relay
  • Basler Electric MOC2499 Motor Operator Control Potentiometer 9072300430
  • Basler Electric BE1-50/51M Overcurrent Relay
  • Basler Electric 9148100106 MOC3502 Solid State Relay 250VDC 0.25A
  • Basler Electric CBS 212 Current Boost System 9265000100
  • Basler Electric 10493002 Control Module
  • Basler BE1-32R D3E E1R A0N1F Power Relay
  • Basler SR8A2B15B3A Static Voltage Regulator
  • Basler IFM-105 Firing Circuit Chassis 9324100105
  • Basler SR4A2B05B3A Static Voltage Regulator
  • Basler BE151G1EB6PB0N0F Protective Relay
  • Basler BE1-59 Electric Over Voltage Relay
  • Basler 277 Static Programmable Powerline Carrier Channel
  • Basler BE1-32R D1E A1P A0N1F Power Relay
  • Basler SR4A1B07B3A Static Voltage Regulator
  • Basler Electric BE1-700 Digital Protective Relay
  • Basler Electric SR8A-2B01B3A Static Voltage Regulator
  • Basler Electric SR4A-2B01B3E Static Voltage Regulator
  • Basler Electric 9017709102 PC Board
  • Basler Electric SR4A-2B01B3A Static Voltage Regulator
  • Basler Electric PRS-250 Veri-Sync Relay
  • Basler Electric 9066800102 Excitation Support System
  • Basler Electric BE1-87G Generator Differential Relay 9 1708 18 100
  • Basler Electric 36T865-2 BE03752001 Power Supply
  • Basler Electric M-300 149D940G02 Power Supply
  • Basler Electric ACA2040-25GM 4Mp 25Fps Area Scan Camera
  • Basler BE1-87G-S1A-A1C-A0N0 Differential Relay
  • Basler SR8A-2B06B3E Static Regulator SR8A2B06B3E
  • Basler SCP-210 Frequency Controller 9095400100
  • Basler BE1-59-A3E-A1J-N1N3F Overvoltage Relay BE159A3EA1JN1N3F
  • Basler 9 2011 11 100 Bracket Mounted Terminal Unit
  • Basler 9 1606 00 101 Voltage Regulator
  • Basler CBS-377 Current Boost System 9109600102
  • Basler 8650C72 Exciter Control Module PCB Rev 5
  • Basler C2EE1PA0N1F BE1-32R Reverse Power Relay
  • ADLINK HPCI-14S12U - Industrial Control Backplane 12PCI Backplane PCI-14S Passive Backplane
  • ADLINK PCIe-GIE74C - image acquisition card 4-CH GigE Vision PoE+ Frame Grabber
  • ADLINK PCI-8164 - control card 4-Axis Advanced Motion Controller Board
  • ADLINK PCIe-U304 - 4 Port USB3 PCIe Frame Grabbers USB Screw Hole Card
  • ADLINK PCI-9112 - Multi-Function Data Acquisition Card DAQ Card
  • ADLINK PCI-7432 - 51-12013-0A50 4-CH Isolated Numérique I/O PCI Cartes Digital I/O Card
  • ADLINK PCA-6106P3-0C1 REV.C1 - backplane 6-Slot Passive Backplane Board
  • ADLINK PCI-7224 - 24-CH Opto-Isolated Digital I/O PCI Board
  • ADLINK CPCI-7433R(G) - Digital Input Board Rear I/O CompactPCI Card
  • ADLINK EBP-13E4 - 51-46703-0A30 Industrial PC Backplane Passive Backplane
  • ADLINK PCIE-HDV62 - Image acquisition card High Definition Video Frame Grabber
  • ADLINK EBP-13E4 - 51-46703-0A30 Industrial Backplane Board Passive Backplane
  • ADLINK 90111-B1 / CPCI-6770 - PCB CPU MODULE CompactPCI Single Board Computer
  • ADLINK PCI-7248 - DATA ACQUISITION PCI CARD 48-CH Parallel Digital I/O Board
  • ADLINK PCI-7230 - 51-12003-0a50 board PCI7230 32-CH Isolated Digital I/O Card
  • ADLINK PCI2A000CB - 51-20000-0B30 Multi-Function DAQ Card Baseboard
  • ADLINK PCI-8134-005 - 4-Axis Motion Controller Card
  • ADLINK PCI-7224 - 24-CH Opto-Isolated Digital I/O PCI Card
  • ADLINK PCI-7434 - 64-CH Isolated Digital Output Card
  • ADLINK PCI-8132 - motion control card 2-Axis Servo & Stepper Controller
  • ADLINK PCI-8134 - Motion Controller PCI Card 4-Axis Controller Board