Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB CAI04 Ability ™  Symphony ®  Plus Hardware Selector
    ❤ Add to collection
  • ABB CAI04 Ability ™ Symphony ® Plus Hardware Selector

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    ABB cAI04 is ABB Ability ™  Symphony ®  The compact analog input module under the Plus series has the core function of processing up to 8 thermocouple (TC) and millivolt (mV) level group isolated field signals, and each channel can be independently configured. The module needs to complete parameter settings through function codes (FC): FC 221 (I/O device definition) is used to set the overall operating parameters of the module, and FC 222 (analog input channel) is used to configure the engineering units, high and low alarm limits, and other details of a single input channel

    • ¥12733.00
      ¥11644.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.570KG
    • Quantity:
    • (Inventory: 99999)
Description

ABB cAI04 is ABB Ability ™  Symphony ®  The compact analog input module under the Plus series has the core function of processing up to 8 thermocouple (TC) and millivolt (mV) level group isolated field signals, and each channel can be independently configured. The module needs to complete parameter settings through function codes (FC): FC 221 (I/O device definition) is used to set the overall operating parameters of the module, and FC 222 (analog input channel) is used to configure the engineering units, high and low alarm limits, and other details of a single input channel




ABB CAI04 ABB Ability ™  Symphony ®  Plus Hardware Selector

Core positioning and basic functions of the product

ABB cAI04 is ABB Ability ™  Symphony ®  The compact analog input module under the Plus series has the core function of processing up to 8 thermocouple (TC) and millivolt (mV) level group isolated field signals, and each channel can be independently configured. The module needs to complete parameter settings through function codes (FC): FC 221 (I/O device definition) is used to set the overall operating parameters of the module, and FC 222 (analog input channel) is used to configure the engineering units, high and low alarm limits, and other details of a single input channel.

Key Performance and Technical Advantages

(1) Signal processing capability

Signal type and range: Supports multiple thermocouple types (international standards: E, J, K, R, S, T, B, L, N (14/28 AWG), U; Chinese standards: E, S, and mV range (0~100 mV or -100~+100 mV).

A/D conversion performance: Each channel has a 16 bit polarized A/D resolution and is equipped with 2 A/D converters (serving 4 input channels each). The update time for 8 channels is only 300 milliseconds, and the accuracy reaches ± 0.05% of the full-scale range (FSR=200 mV).

Cold end compensation: supports three configurable methods, namely built-in RTD on module mounting base, external RTD connected to module base TB3, and user configured independent application input.

(2) Reliability and Protection

Isolation performance: 1500V 1-minute galvanic isolation is achieved between on-site signals and logic circuits, and 1 × 8 groups of isolation are used for channels (also 1500V 1-minute).

Anti interference capability: The minimum normal mode noise suppression is -70 dB, and the minimum common mode noise suppression (including DC) is -90 dB. At the same time, it has passed multiple electromagnetic compatibility (EMC) tests, such as ESD immunity, surge immunity, etc. (all reaching IEC/EN standard Severity level 3 or 4).

Diagnosis and maintenance: The front panel is equipped with a STATUS indicator light (R running light, F fault light, and 1-8 channel lights), supports mini USB local connection, and can achieve remote diagnosis of HN800 devices through SPE; The open circuit detection time is less than 5 seconds and does not require manual calibration, with automatic calibration function.


Basic Information and Environmental Adaptability

(1) General Information

Product number: 2VAA008414R1, with a lifecycle status of "ACTION" (in service), no HART, SOE function or redundant design, compact appearance (127 mm), supporting horizontal row or vertical column installation.

Power requirements: 24 VDC ± 10%, typical current 65 mA, maximum current 73 mA, power supply connected to POWER TB of cHBX01L or VBX01T; The overvoltage category is Class I (compliant with EN 61010-1 standard), with a maximum on-site cable length of 600 meters (1968 feet).

Reliability index: According to MIL-HDBK-217-FN2 standard, the mean time between failures (MTBF) at PR A level is 327498 hours, and the mean time to repair (MTTR) is 1 hour.

(2) Environment and Compliance

Environmental tolerance range: operating temperature -40~+70 ℃ (compliant with IEC/EN 60068-2-1/2 standard), storage temperature -40~+85 ℃ (compliant with MIL-STD-810G standard); Relative humidity of 20%~95% (no condensation at 40 ℃, in compliance with IEC/EN 60068-2-78 and other standards); It can adapt to altitudes ranging from 0 to 3048 meters (for work) and 0 to 12192 meters (for storage), and meets the ISA S71.04 G1/G3 air quality standards (SPCxxxA version is optional).

Mechanical environment tolerance: working sine vibration of 5-60 Hz (0.137 mm), 60-150 Hz (1.0 G, in accordance with IEC/EN 60068-2-6 standard); Transport vibration of 10-500 Hz (compliant with MIL-STD-810G standard); Storage impact of 15 G (11 milliseconds, compliant with IEC/EN 60068-2-27 standard); Drop tolerance of 100 mm (compliant with IEC/EN 60068-2-31 standard), protection level IP20 (compliant with EN 60529 standard).

Compliance certification: Passed CE certification (compliant with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC), RoHS compliance (Directive 2015/863), WEEE compliance (Directive 2012/19/EU); CSA certification covers ordinary non hazardous locations, as well as Class I Zone 2 A/B/C/D hazardous non flammable locations.


Compatibility and physical specifications

(1) Compatibility

It needs to be used in conjunction with MTU base cHBS01 CJC and cVBS01 CJC. The key code for slot 1 of the base is 10, and slot 2 is 17.

(2) Size and weight

Dimensions: Width 27 mm, Depth 106 mm, Height 127 mm;

Weight: 168 g.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide