  • ABB CAI04 Ability ™  Symphony ®  Plus Hardware Selector
    ❤ Add to collection
  • ABB CAI04 Ability ™ Symphony ® Plus Hardware Selector

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    ABB cAI04 is ABB Ability ™  Symphony ®  The compact analog input module under the Plus series has the core function of processing up to 8 thermocouple (TC) and millivolt (mV) level group isolated field signals, and each channel can be independently configured. The module needs to complete parameter settings through function codes (FC): FC 221 (I/O device definition) is used to set the overall operating parameters of the module, and FC 222 (analog input channel) is used to configure the engineering units, high and low alarm limits, and other details of a single input channel

    • ¥12733.00
      ¥11644.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.570KG
    • Quantity:
    • (Inventory: 99999)
Description

ABB cAI04 is ABB Ability ™  Symphony ®  The compact analog input module under the Plus series has the core function of processing up to 8 thermocouple (TC) and millivolt (mV) level group isolated field signals, and each channel can be independently configured. The module needs to complete parameter settings through function codes (FC): FC 221 (I/O device definition) is used to set the overall operating parameters of the module, and FC 222 (analog input channel) is used to configure the engineering units, high and low alarm limits, and other details of a single input channel




ABB CAI04 ABB Ability ™  Symphony ®  Plus Hardware Selector

Core positioning and basic functions of the product

ABB cAI04 is ABB Ability ™  Symphony ®  The compact analog input module under the Plus series has the core function of processing up to 8 thermocouple (TC) and millivolt (mV) level group isolated field signals, and each channel can be independently configured. The module needs to complete parameter settings through function codes (FC): FC 221 (I/O device definition) is used to set the overall operating parameters of the module, and FC 222 (analog input channel) is used to configure the engineering units, high and low alarm limits, and other details of a single input channel.

Key Performance and Technical Advantages

(1) Signal processing capability

Signal type and range: Supports multiple thermocouple types (international standards: E, J, K, R, S, T, B, L, N (14/28 AWG), U; Chinese standards: E, S, and mV range (0~100 mV or -100~+100 mV).

A/D conversion performance: Each channel has a 16 bit polarized A/D resolution and is equipped with 2 A/D converters (serving 4 input channels each). The update time for 8 channels is only 300 milliseconds, and the accuracy reaches ± 0.05% of the full-scale range (FSR=200 mV).

Cold end compensation: supports three configurable methods, namely built-in RTD on module mounting base, external RTD connected to module base TB3, and user configured independent application input.

(2) Reliability and Protection

Isolation performance: 1500V 1-minute galvanic isolation is achieved between on-site signals and logic circuits, and 1 × 8 groups of isolation are used for channels (also 1500V 1-minute).

Anti interference capability: The minimum normal mode noise suppression is -70 dB, and the minimum common mode noise suppression (including DC) is -90 dB. At the same time, it has passed multiple electromagnetic compatibility (EMC) tests, such as ESD immunity, surge immunity, etc. (all reaching IEC/EN standard Severity level 3 or 4).

Diagnosis and maintenance: The front panel is equipped with a STATUS indicator light (R running light, F fault light, and 1-8 channel lights), supports mini USB local connection, and can achieve remote diagnosis of HN800 devices through SPE; The open circuit detection time is less than 5 seconds and does not require manual calibration, with automatic calibration function.


Basic Information and Environmental Adaptability

(1) General Information

Product number: 2VAA008414R1, with a lifecycle status of "ACTION" (in service), no HART, SOE function or redundant design, compact appearance (127 mm), supporting horizontal row or vertical column installation.

Power requirements: 24 VDC ± 10%, typical current 65 mA, maximum current 73 mA, power supply connected to POWER TB of cHBX01L or VBX01T; The overvoltage category is Class I (compliant with EN 61010-1 standard), with a maximum on-site cable length of 600 meters (1968 feet).

Reliability index: According to MIL-HDBK-217-FN2 standard, the mean time between failures (MTBF) at PR A level is 327498 hours, and the mean time to repair (MTTR) is 1 hour.

(2) Environment and Compliance

Environmental tolerance range: operating temperature -40~+70 ℃ (compliant with IEC/EN 60068-2-1/2 standard), storage temperature -40~+85 ℃ (compliant with MIL-STD-810G standard); Relative humidity of 20%~95% (no condensation at 40 ℃, in compliance with IEC/EN 60068-2-78 and other standards); It can adapt to altitudes ranging from 0 to 3048 meters (for work) and 0 to 12192 meters (for storage), and meets the ISA S71.04 G1/G3 air quality standards (SPCxxxA version is optional).

Mechanical environment tolerance: working sine vibration of 5-60 Hz (0.137 mm), 60-150 Hz (1.0 G, in accordance with IEC/EN 60068-2-6 standard); Transport vibration of 10-500 Hz (compliant with MIL-STD-810G standard); Storage impact of 15 G (11 milliseconds, compliant with IEC/EN 60068-2-27 standard); Drop tolerance of 100 mm (compliant with IEC/EN 60068-2-31 standard), protection level IP20 (compliant with EN 60529 standard).

Compliance certification: Passed CE certification (compliant with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC), RoHS compliance (Directive 2015/863), WEEE compliance (Directive 2012/19/EU); CSA certification covers ordinary non hazardous locations, as well as Class I Zone 2 A/B/C/D hazardous non flammable locations.


Compatibility and physical specifications

(1) Compatibility

It needs to be used in conjunction with MTU base cHBS01 CJC and cVBS01 CJC. The key code for slot 1 of the base is 10, and slot 2 is 17.

(2) Size and weight

Dimensions: Width 27 mm, Depth 106 mm, Height 127 mm;

Weight: 168 g.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration