<span style="font-size: 18px; font-family: arial;">OMRON CJ1W-SCU32 Serial Communication Unit</span>

OMRON CJ1W-SCU32 Serial Communication Unit for CJ Series PLCs

The OMRON CJ1W-SCU32 is a high-performance serial communication module designed for the CJ1, CJ2, and CS1 series PLCs (when used in a CJ rack). It provides two independent serial ports: one RS-232C and one RS-422A/485 (switchable). The unit supports protocol macros, Modbus RTU (master and slave), Host Link (SYSMAC WAY), NT Link, and no-protocol communication. This makes it ideal for connecting HMIs, barcode readers, weigh scales, serial printers, variable frequency drives, and other serial devices to the PLC without custom programming.


Port Specifications

Port 1 is RS-232C (9-pin D-sub male) with a maximum cable length of 15 meters. Port 2 is RS-422A/485 (5-pin removable terminal block) supporting 2-wire or 4-wire configurations, with a maximum distance of 500 meters. Both ports are electrically isolated from the PLC backplane and from each other. Baud rates are selectable from 1200 to 115200 bps, with data bits (7 or 8), parity (none, even, odd), and stop bits (1 or 2) configurable per port.

::::

ParameterPort 1 (RS-232C)Port 2 (RS-422/485)
Connector9-pin D-sub male5-pin terminal block
Cable length15 m max500 m max
Isolation500 VAC500 VAC
ProtocolsProtocol macro, Modbus, Host Link, NT Link, No-protocolSame
Baud rate1200 to 115200 bps1200 to 115200 bps


Protocol Macro Function

The protocol macro feature allows the CJ1W-SCU32 to communicate with virtually any serial device by defining send/receive sequences using the CX-Protocol software (included with CX-One). Up to 1000 protocol sequences can be stored in the unit’s flash memory. Each sequence can include conditional branching, checksum calculation, and timeout handling. This eliminates the need to write complex communication logic in the PLC ladder program. The unit also supports Modbus RTU master function (reading/writing coils and registers) and slave function (responding to Modbus requests).

Data Exchange with PLC CPU

The SCU32 exchanges data with the CPU via special I/O words allocated in the CIO area and DM area. Each port has a 256-byte send buffer and 256-byte receive buffer. Data can be transferred using simple MOV instructions or using the built-in “TXD” and “RXD” instructions for no-protocol mode. For protocol macro and Modbus, the unit automatically transfers data between its buffers and the CPU’s DM area without user ladder programming. The unit also supports high-speed data links (up to 10 ms cycle) when using the Host Link or NT Link protocols.

Configuration and Setup

Configuration is performed using the CX-Integrator or CX-Programmer software. The unit’s node number (unit number) is set via rotary switches on the front panel (0 to 95). Port settings are defined in the PLC’s DM parameter area (special DM words). Alternatively, the CX-Protocol software can create and download protocol macro data. The SCU32 has 16 diagnostic LEDs (green/red) on the front to indicate power, port activity, and communication errors. The unit supports hot-swapping (installation and removal with power off only, but can be inserted with power off).

Environmental and Mechanical Data

The CJ1W-SCU32 is a CJ-series module measuring 90mm (H) x 31mm (W) x 90mm (D) and weighing 120 g. It requires a CJ-series backplane and consumes 300 mA from the 5 VDC backplane supply (no external 24V needed). Operating temperature: 0°C to 55°C, storage -20°C to 75°C. Humidity: 10% to 90% non-condensing. The unit is rated IP20 and meets CE, UL, and RoHS standards. It is designed for pollution degree 2 environments.

Typical Applications

The CJ1W-SCU32 is widely used for: connecting a barcode scanner to read product codes into the PLC, interfacing a weigh scale for batching systems, communicating with a variable frequency drive via Modbus RTU for speed control, linking to an HMI (Pro-face, Omron) via Host Link, and connecting a serial printer for alarm logging. Its two independent ports can serve two different devices with different protocols simultaneously. The unit is also used in legacy system upgrades where existing serial devices must be retained.

Installation and Ordering

Order number: CJ1W-SCU32. The unit is supplied with a terminal block for port 2 (RS-422/485) and a dust cover. A 9-pin D-sub cable (e.g., CJ1W-CN226) is required for port 1. For RS-422/485 wiring, use shielded twisted-pair cable. The unit is compatible with all CJ1, CJ2, and CS1 (with CJ adapter) CPUs. For applications requiring only one RS-232C port, consider the CJ1W-SCU22. The SCU32 is fully supported by CX-One software version 4.0 or later. OMRON provides a 2-year warranty.


HCIX15-TE-FA-NC Heavy-Duty Limit Switch
UNITROL1000 B-Z V104 3BHE014557R6104 Excitation System Controller / AVR-PSS Module (for UNITROL 1000)
ABB Unitrol 1000-7 Digital Static Excitation System
Woodward 5501-381 Fuel Metering Valve / Servo Valve
A-B 1797-PS2N2 DC Input Power Supply (for 1797 FLEX I/O System)
ELAU MC-4/11/03/400 Digital Servo Drive
ELAU MC-4/11/22/400 Digital Servo Drive
MC-4/11/10/400 Digital Servo Drive
ABB UNC4672AV1 HIEE205012R0001 Interface Module / Signal Conditioning Board
80190-800-01-R Communication Interface Module / Network Adapter
KONGSBERG RCU502I 421768 Remote Control Unit (Modular I/O & Control Module)
XVS-460-57MPI-1-10 Variable Frequency Drive (AC Drive)
LinMot E1250-EC-UC Tubular Linear Servo Motor (Actuator)
PP D539 A102 Protection Relay Module / System Controller Component 3BHE039770R0102
HONEYWELL LG1093AC01 Precision Limit Switch
MCS2000-DRV2 Digital Servo Drive Module
1TGE120021R0810 Numerical Distance & Line Differential Protection Relay (REL 670 series)
1TGE120021R0110 Numerical Distance & Line Differential Protection Relay (REL 670 series)
1TNA920611R0002 Auxiliary Contact Block (Side-Mounting)
1TGE120011R1000 Numerical Line Differential Protection Relay (REL 670 series)          
  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector
  • Microchip PIC16F182X Low Power Design
  • FANUC α iS servo HRV calibration practice
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide