Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200TCEBG1B Common Circuits for EOS Board
    ❤ Add to collection
  • GE DS200TCEBG1B Common Circuits for EOS Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200TCEBG1B Common Circuits for EOS Board

    • ¥22000.00
      ¥24520.00
      ¥22000.00
      ¥22000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE DS200TCEBG1B Common Circuits for EOS Board


GE DS200TCEBG1B Common Circuits for EOS Board

Part Number DS200TCEBG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCEBG1B is a Protective Termination Expander Board and is part of the GE Speedtronic Mark V gas turbine control system. This board is located in the P1 Core location 2, Scales the potential transformer and current transformer used by the TCCB boards in the R5. These signals are used for the generator and bus voltages and line current and are landed on the PTBA terminal board. There are no hardware jumpers on the TCEB board for the configuration. The alarm horn jumper is located on the PTBA terminal board. There is no software configuration on the TCEB board.

DS200TCEBG1B (GE Protective Termination Expander Board) features 3 bayonet connectors, 4 signal transformers, one 26-pin connector, four 10-pin connectors and three 20-pin connectors. DS200TCEBG1B (Mark V series) diagnostic tools are limited, although, you can use the available diagnostic tools on the drive to understand the board and all components in the drive. DS200TCEBG1B (Mark V series) diagnostics will generate a report that includes all warning, error and trip conditions generated by the drive.nnThe diagnostic report of DS200TCEBG1B (Mark V series) also includes the details of the boards in the drive. From DS200TCEBG1B?s report, you can find the cause of the problem and how to resolve the issue. 

Through a serial cable, you can upload the report to a laptop that is connected to the drive.?nnDS200TCEBG1B (Mark V series) is located in the core. DS200TCEBG1B holds the microprocessor circuitry for the protection of DS200TCEBG1B (Mark V series), the DS200TCEBG1B (Mark V series) being known as the protective processer.?nnDS200TCEBG1B (GE Protective Termination Expander Board) scales the PT and CT signals used by the TCCB board, which are used for the generator, bus voltages and line current, which are then landed on the PTBA terminal board.

OTHER INFORMATION

Hardware Tips and Specifications

The General Electric Protective Termination Expander Board model DS200TCEBG1B features a complete total of 3 bayonet connectors, 4 signal transformers, and 1 26-pin connector. It also contains 4 10-pin connectors and 3 20-pin connectors. The GE Protective Termination Expander Board DS200TCEBG1B is limited in the diagnostic tools available if you suspect that the board is not operating as you expected. However, you can use the diagnostic tools available on the drive to gain insight into the board and all components in the drive. The diagnostics generate a report that details all warning, error, and trip conditions generated by the drive. The various connectors made available to the assembly of this DS200TCEBG1B Protective Termination Expander Board are described in detail in the DS200TCEBG1B instructional manual attached above, for your convenience. As with any individual hardware component in this DS200TCEBG1B printed circuit board product offering's assembly, this DS200TCEBG1B PCB's connectors are all identifiable through their own individual corresponding factory-printed nomenclature labels. Some of this DS200TCEBG1B PCB's various connectors include:

The JKX/Y/Z TCEA Board Various Signals Connector

The JMP TCCB Board PT and CT Signals Connector

The JU PTBA Board Magnetic Pickup and Flame Detection Signals Connector

The JV PTBA Board PT and CT Signals Connector

The JVA PTBA Board UV Flame Detection Signals Connector

The JWX/Y/Z TCEA, TCEB, and PTBA Boards 335 V dc Signals Connector

The JPU Connector

The JPV Connector

The JPW Connector

Instructions and warnings related to the operation of the product:

The following specifications must be strictly observed:

 The technical specifications and typical applications of the product system must be strictly observed.

 PERSONNEL TRAINING: Only trained personnel may install, operate, maintain or repair the product system. These personnel must be instructed on the

These personnel must be instructed and briefed on the conditions in the hazardous area.

 Unauthorised modifications: No modifications or structural changes may be made to the product system.

 Maintenance Responsibility: It must be ensured that the product system is used only under appropriate conditions and in a condition fully suitable for use.

 Working environment: The user must fulfil the specified environmental conditions:

Safety regulations

The following safety regulations must be fully observed when (maintenance) work is carried out on the product system:

1 Disconnect completely.

2 Secure to prevent reconnection.

3 Confirm that the installation has been completed.

4 Perform grounding and short-circuiting.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide
  • Pro face PFXSTM6400WAD human-machine interface
  • Pacific Scientific 6410 Stepper Driver
  • Parker EVM32-II Modular Expansion Base Plate
  • Parker COMPAX series compact servo controller: integrated motion control and drive
  • Parker Compumotor ZETA6000 Single Axis Drive Controller
  • PI C-663.12 Mercury Step Motor Controller
  • NetTest TUNICS series tunable external cavity laser
  • Complete Guide to Inline Automation Terminal System
  • Phoenix FL MC 1000 SC (ST) Fiber Optic Converter
  • Phoenix ST series spring cage terminal block
  • ROSS Pneumatic Valve Full Series
  • BD SENSORS DMP 333 High Pressure Transmitter
  • OE Max Controls NX70 series PLC
  • SAIA PCD4.W500/W600 Intelligent Simulation Module
  • Saia Burgess PCD4.U100 Migration Kit
  • SAIA PCD1 Controller Full Series
  • SAIA Burgess PCD2.H110 Counting and Measurement Module
  • SAMSON Type 3434 Pneumatic Controller Module
  • SanDisk iNAND Flash and microSD
  • Optimus® Product Family of SAS SSDs
  • SANMOTION PB servo stepper
  • ADCA AVM/AVF234S electric actuator
  • SBS Technologies VIPC616 Carrier Board
  • SBS Technologies VIPC616 VME Carrier Board
  • Greenspring P2 Video Graphics Controller
  • ABB UniPack-S Steel Compact Substation
  • Schaffner Ecosine ® Economy Line FS 42842 Compact Passive Harmonic Filter
  • Schenck Process INTECONT Tersus Weighing Instrument
  • ENTRELEC contactor relay
  • Smiths Connectors MHD/MDD/MDP CONNECTOR SERIES PCB High Density Connectors
  • SEW EURODRIVE DFP21B bus interface
  • SEW-EURODRIVE MOVIDRIVE B Series Manual
  • SEW Eurodrive R series parallel axis reduction motor
  • SEW EURODRIVE DFY/DFS Synchronous Motor Guide
  • SEW MOVITRAC 31C Installation and Debugging
  • SEW EURODRIVE MOVIDYN communication interface
  • SEW MOVIDRIVE UL compliant installation
  • SEW MOVIDRIVE bus positioning
  • SEW MOVIDYN ® Series servo controller
  • SEW MOVIDRIVE MD60A Inverter Guide
  • BTicino Megatiker M5 electronic circuit breaker
  • BTicino Megatiker M4 Circuit Breaker
  • BTicino Megatiker M3 160 Circuit Breaker
  • BTICINO MEGATIKER Circuit Breaker Series
  • Elmex Industrial Automation Control Products
  • Danfoss VLT ® Series 3000 series adjustable frequency drive
  • Rockwell Automation SLC 500 Series Programmable Logic Controller
  • YOKOGAWA CENTUM CS 3000 Integrated Production Control System
  • OMRON SYSMAC CS Series CS1G/H-CPU  H Programmable Controller
  • MEGGITT TQ TQ 422/432 Eddy Current Measurement System
  • MEGGITT VM600 machinery protection system (MPS)
  • IbaDeskline SAS Industrial Computer
  • IbaDAQ-C independent data acquisition device
  • IbaFOB io ExpressCard fiber optic interface card
  • IbaPADU-S-IT-16 modular central unit
  • YASKAWA ∑ - II Series SGMBH/SGDH AC Servo System
  • IbaBM CAN CAN/CANopen bus sniffer
  • IbaLink-SM-128V-i-2O VMEbus interface board
  • GE Fanuc Series 90-30 PLC Hardware System
  • Automation Direct GS2 Series Frequency Inverter Specifications and Selection
  • OMRON SYSDRIVE 3G3MV Multi-functional Compact Frequency Inverter In-depth Technical Guide
  • Danfoss VACON NXI High Power Frequency Inverter Operation Manual
  • Saia PCD4.U100 Kit System Upgrade Guide
  • Yaskawa Sigma II Series NS300 DeviceNet Application Module Deep Technical Guide
  • OMRON SSS Software C-series PLC Operating Instructions
  • Kollmorgen SERVOSTAR S Digital Servo Drive Guide: From Installation to Mastery
  • Omron C200HX/HG/HE PLC Installation Guide
  • SIEMENS SINAMICS S120 Servo Drive System Application Guide
  • Emerson ControlWave Micro Hybrid Controller
  • ABB 800xA with Advant Master integrated configuration