GE IC697PWR711/713 Power Supply Module


GE IC697PWR711/713 Power Supply Module

INTRODUCTION

The 100 Watt Power Supply Module is a rack-mounted unit that plugs directly into a 48-pin backplanemounted connector in the leftmost slot in the rack. It provides +5 volt, +12 volt and -12 volt power, and logic level sequencing signals to the backplane. This power supply may be used either in a single rack application, or may also be used to provide power to a second rack if the total load is within the supply rating. Interconnection to the second rack is through a prewired cable.

Features

 Operation from 120 VAC, 240 VAC, or 125 VDC 

 Three output voltages, 100 watts total +5 VDC output up to 20 amps +12 VDC output up to 2 amps -12 VDC output up to 1 amp 

 Slide-in rack mount construction 

 Electronic short circuit overcurrent protection 

 Two rack operation from a single power supply 

 Power Factor correction for AC operation 

 Jumper for overvoltage protection devices

Operation of the Power Supply

This Power Supply module can operate from either 120 VAC or 240 VAC nominal inputs. It will also operate from a nominal 125 VDC source. The specified range of operation is from 90 VAC to 264 VAC, and from 100 VDC to 150 VDC.

For continuous operation (greater than one hour) at low line voltages and high temperatures, some power derating must be applied. Refer to the following figure to determine the normal operating range for specific applications. Normal operating range is shown by the shaded area of the graph for 60C (140F) installations. Operation in the non-shaded region for specific applications must be limited to <1 hour. Reducing the maximum operating temperature to 55C (131F) will increase the normal operating range as indicated on the graph.

Overvoltage Protection

An electronic shutdown circuit protects against voltages exceeding 6.2 volts. A back-up voltage clamp is provided to protect against sustained overvoltage conditions due to either external influences or internal faults. Overvoltage due to internal faults may cause the fuse to open. For short term overvoltage conditions, normal operation will resume when the cause is removed.

Overcurrent Protection

An electronic current limit is provided on each of the three outputs. An overload on any output will cause the voltage to collapse and may cause the other output voltages to collapse. Normal operation will resume after removal of the overload. Some component cooling time may be required before normal operation resumes.

Dual Rack Operation

A single power supply can provide power for two racks under the following conditions: 

 Only 5 volt power is required in the second rack, and the total power required by both racks is with-in the capability of the supply. 

 The current drawn by the second rack is less than 5.2 amperes. 

 The two racks must be mounted in close proximity as limited by the available 3-foot connecting cable. 

The connecting cable used for dual rack operation is listed in Table 2, Ordering Information. This cable carries the +5 volts power bus as well as the power sequencing signals. It uses a 9-pin D-type connector which connects directly to the backplane through an opening in the rack frame. Note that the cable carries power and power sequencing signals only. Inter-rack communication and bus interface modules must be provided separately. See the applicable Programmable Controller Installation Manual. for application information.

Field Wiring Connections

The power input terminal board has four terminals. The top two (L1 and N) are for 120/240 VAC or 125 VDC input power connections; the third and fourth terminals are for ground and overvoltage protection device connections, respectively. Power input connections should be made with copper AWG #16 (1.3 mm2 ) wire rated for 75C (167F). Each terminal can accept solid or stranded wires, but the wires into any given terminal should be the same type and size.

Power Supply Door

The power supply door can easily be opened by grasping the upper left corner of the door with your right thumb or a fingernail and gently pulling the door towards you. Use care when opening the door since pulling from the bottom can cause the hinge or the door to break.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • KONGSBERG C-series precision cutting system: versatile digital cutting solution
  • KONGSBERG DPS i2 Inertial Navigation System: A New Benchmark for GNSS and INS Fusion Positioning
  • KONGSBERG DPS 114 Durable and Reliable DGNSS (DGPS/DGGLONASS) Sensor
  • KONGSBERG DZ-110/U transmitter safety barrier unit
  • KONGSBERG DZ-120 Zener Safety Barrier Unit
  • KONGSBERG MST 319/324/342 series mini SSBL responder
  • BridgeMaster E 180 and 250 EPA (L) Series of Marine Radars
  • KONGSBERG K-Chief 600 Control Room Panel (CRP) for Ship Automation System
  • KONGSBERG K-Master Bridge Solution: Comprehensive Enhancement of Ship Operation Efficiency and Safety
  • KONGSBERG SR/SV Steering Servo Maintenance Comprehensive Guide
  • KONGSBERG GT300 pressure transmitter
  • KONGSBERG's RMP420 Remote Multifunctional I/O Module
  • KONGSBERG WCU LED Control Unit Application Guide
  • KONGSBERG K-Nav Navigation Product Series
  • KONGSBERG K-Chief Ship Automation System
  • KONGSBERG RCU 500 Remote Controller
  • Kongsberg ACC20 Engine Safety Unit: Redundant Guardian of Industrial Power
  • KUKA KR C5 Robot Controller
  • KUKA KR C4 compact robot controller
  • KUKA KR C2 edition2005 Robot Controller Operation Manual
  • EATON A200 Size 5 Motor Controller
  • Eaton MICRO PANEL XV-152 Industrial Tablet Operating Manual
  • Eaton B-Line series product line
  • EATON Time delay undervoltage module
  • Eaton 5P series UPS products
  • Cooper Crouse Hinds EVLS HAZARD-GARD Explosion proof Lamp Installation and Maintenance
  • Eaton EX series UPS products
  • Durant Ambassador 57600 Series Counting Controller
  • Eaton xEnergy Safety Ci Insulated Distribution Enclosure
  • EATON XP-702 MICRO PANEL Industrial grade Human Machine Interface Equipment
  • EATON SPD series surge protector
  • EATON MVX9000 Variable Frequency Drive
  • EATO NeasyE4 Micro PLC Easy Control
  • EATON Cutler Hammer FP-4000 Medium Voltage Feedline Protection Relay
  • EATON FP-4000 feeder protection relay
  • EATON XT series stabilizing pump control box
  • EATON MP-4000 motor protection relay
  • EATON ELPRO 245U-E series industrial wireless Ethernet products
  • EATON MTL4850 HART multiplexer complete guide
  • Eaton Ambassador Counter Complete Guide
  • EATON Crouse Hinds LED Explosion proof Lighting Guide
  • Eaton 9000X Inverter Complete Guide
  • Eaton S801+Soft Starter Complete Guide
  • Eaton XV300 Multi Touch Display Screen
  • EATON XV200 Micro Panel Comprehensive Guide
  • Eaton CEAG CG Controller Comprehensive Guide
  • Eaton K Series OPTIM Circuit Breaker Installation Guide
  • EATON Series C Plastic Case Circuit Breaker and Motor Circuit Protector
  • EATON MP-3000 Motor Protection Relay
  • EATON XV-303/XV-313 series industrial multi touch HMI display
  • EATON VISA series vacuum arc extinguishing chamber
  • EATON FP-5000 protective relay
  • Eaton IQ500 Series Multifunctional Power Mete
  • EXOR eTOP Series 300 Operation Panel
  • UniOP MD02F/R series compact HMI technology explanation and application guide
  • UniOP CP02 series high-end compact HMI
  • UniOP CP01R-04, CP05R-04, and CP01F-02 Compact Low Cost HMI Devices
  • UniOP ECT-16 Industrial PLC Workstation Operator Interface System
  • UniOP ePALM10 Handheld Human Computer Interface
  • UniOP ePAD03/ePAD04 Human Computer Interface
  • Union Special XF500 Industrial Sewing Machine Maintenance Guide
  • UniOP Operation Panel Installation and Maintenance Guide
  • UniOP eTOP306 Industrial Touch Screen
  • UniOP Universal Operation Panel Installation Guide
  • ABB AX400 series low conductivity analyzer(AX411/511010)
  • Allen Bradley SLC 500 Programmable Controller System Selection Guide
  • WITTENSTEIN alpha LP+/LPB+low backlash planetary gear reducer
  • ABB AX400 Series AX460/AX466 pH/ORP Analyzer User Guide
  • ALSTOM ALSPA series drives
  • ALSTOM ALSPA P1200NT Tripping and Control Relays
  • GE MVAJ Trip Relay: Protection and Control Core
  • GE Vernova MVAW 11/13/21 type intermediate relay
  • ALSTOM ALSPA MV1000 Intelligent Variable Frequency Drive
  • GE Vernova MMLG/MMLB Test Blocks and Test Plugs
  • Baker Hughes 1900/65A General Purpose Equipment Monitor
  • DEIF LSU-112DG generator set parallel control unit
  • DEIF PPM 300 Ship Power Generation Management Controller
  • DEIF DELOMATIC 3 Generator Set Control System
  • DEIF DELOMATIC 400 Gas Engine Unit Control System
  • DEIF Multi line 2 Option X Guide
  • Dell EMC Networking X-Series Switches
  • Eaton MP-3000 Motor Protection Relay Guide
  • Eaton TX series cam switch and PX series load isolation switch
  • Eaton XControl Modular PLC Complete Guide
  • Eaton XVS400 5.7-inch Touch Screen Analysis
  • Emerson PAC8000 Remote I/O Complete Analysis
  • Eaton XV Supercapacitors Complete Guide
  • Eaton XV400 Industrial Tablet Complete Guide
  • Eaton Plastic Case Circuit Breaker Technology Analysis and Application Guide
  • Emerson PR9268 Electric Speed Sensor
  • Emerson Micro Motion High Precision HPC010/HPC015 Series High Pressure Coriolis Flow Meter Installation Guide
  • Emerson PACSystems RX3i Programmable Automation Controller
  • Emerson AMS 6500 ATG Machinery Protection System
  • Emerson Ovation I/O System
  • Emerson DeltaV ™ S-series Traditional I/O
  • EMERSON DeltaV™ M-series Traditional I/O
  • Oil Proof Fans San Ace 40WF, San Ace 60WF, San Ace 80WF, and San Ace 92WF
  • FANUC α i Series Servo and Spindle System Maintenance Guide
  • GE i Series CNC System Operation Panel Comprehensive Guide
  • FANUC Series 0+-MODEL F Plus
  • FANUC α i-B/β i-B series servo system
  • HIMA ELOP II-NT Safety PLC Programming System
  • HIMA HIMax Safety Related Controller System
  • HIMax X-FAN system fan
  • HIMA H41q/H51q Safety PLC System
  • HIMA HIQuad X Series Safety Programmable Electronic System (PES)
  • HIMA HIMatrix series compact safety controller
  • HIMA HIMatrix F3 DIO 20/8 02 Series Safety Related Remote I/O Modules
  • HIMA F8650X Safety Central Module
  • HIMA H41q and H51q series programmable electronic systems (PES)
  • HIRSCHMANN PowerMICE series industrial Ethernet switches
  • HIRSCHMANN MS20/MS30 series industrial Ethernet switches
  • HITACHI SAM PS100 series pressure based PI mass flow controller
  • HITACHI Advanced Server DS7000 Series Scalable Servers
  • HITACHI LH1 series universal vector frequency converter
  • HITACHI frequency converter Cs-H100 series
  • MVH series high temperature resistant aluminum electrolytic capacitors
  • HITACHI EH-150 PLC in depth analysis: characteristics, instructions, and system design
  • Honeywell Fusion4 MSC-L Multi Stream Loading Controller
  • Honeywell IPC 620-06 Programmable Controller
  • Honeywell Enhanced Micro TDC 3000 Control System
  • Honeywell Expert LS I/O System
  • Honeywell Expert PKS Universal Process Cabinet
  • KEBA KeConnect I/O: Modular Industrial Automation I/O System
  • KEBA FM 299/A GA1060 fieldbus main module
  • KEBA KeControl C1 CP 03x: Highly Integrated Embedded Industrial Controller
  • KEBA KeControl series controllers
  • KEBA KeConnect C5: High density modular IO system empowering industrial automation