Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB HK1 - 11 Auxiliary Contacts Critical Connectors for Industrial Electrical Systems
    ❤ Add to collection
  • ABB HK1 - 11 Auxiliary Contacts Critical Connectors for Industrial Electrical Systems

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    Product positioning and function: HK1-11 auxiliary contacts are designed for use with ABB related electrical equipment, 

    mainly used to reflect the working status of the main contacts of switches and contactors in the main circuit, 

    and transmit these status signals to other parts of the control system to realize remote monitoring, signal feedback and logic control of the circuit, etc. 

    For example, in motor control circuits, the main contacts of contactors can be closed by means of HK1-11 auxiliary contacts. 

    For example, in the motor control circuit, through the HK1 - 11 auxiliary contact, 

    the closing or disconnecting status of the main contact of the contactor can be transmitted to the control center, 

    so that the operator can know the running status of the motor in real time.

    Product family affiliation: It is a member of the ABB electrical equipment accessory system and is closely aligned with 

    ABB's manual motor starters (models MS116, MS132, MS165, etc.). 

    This close correlation ensures seamless collaboration and optimal performance of the components in the entire electrical system.


    • ¥18519.00
      ¥5817.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:18.090KG
    • Quantity:
    • (Inventory: 99999)
Description

Product positioning and function: HK1-11 auxiliary contacts are designed for use with ABB related electrical equipment, 

mainly used to reflect the working status of the main contacts of switches and contactors in the main circuit, 

and transmit these status signals to other parts of the control system to realize remote monitoring, signal feedback and logic control of the circuit, etc. 

For example, in motor control circuits, the main contacts of contactors can be closed by means of HK1-11 auxiliary contacts. 

For example, in the motor control circuit, through the HK1 - 11 auxiliary contact, 

the closing or disconnecting status of the main contact of the contactor can be transmitted to the control center, 

so that the operator can know the running status of the motor in real time.

Product family affiliation: It is a member of the ABB electrical equipment accessory system and is closely aligned with 

ABB's manual motor starters (models MS116, MS132, MS165, etc.). 

This close correlation ensures seamless collaboration and optimal performance of the components in the entire electrical system.



ABB HK1 - 11 Auxiliary Contacts: Critical Connectors for Industrial Electrical Systems

Product Basics Overview

Product positioning and function: HK1-11 auxiliary contacts are designed for use with ABB related electrical equipment, 

mainly used to reflect the working status of the main contacts of switches and contactors in the main circuit, 

and transmit these status signals to other parts of the control system to realize remote monitoring, signal feedback and logic control of the circuit, etc. 

For example, in motor control circuits, the main contacts of contactors can be closed by means of HK1-11 auxiliary contacts. 

For example, in the motor control circuit, through the HK1 - 11 auxiliary contact, 

the closing or disconnecting status of the main contact of the contactor can be transmitted to the control center, 

so that the operator can know the running status of the motor in real time.

Product family affiliation: It is a member of the ABB electrical equipment accessory system and is closely aligned with 

ABB's manual motor starters (models MS116, MS132, MS165, etc.). 

This close correlation ensures seamless collaboration and optimal performance of the components in the entire electrical system.


Product structure and design features

Structure: It is mainly composed of contacts, springs, insulating shells and connecting terminals. 

Contacts as the core components, made of high quality conductive materials, such as silver alloy, 

with good electrical conductivity and anti-melting performance, in the frequent on and off operation, 

can stably transfer the current to reduce the contact erosion, prolong the service life. 

The spring provides power for the action of the contact to ensure that the auxiliary contact can respond quickly and accurately 

when the main contact state changes. The insulating shell is made of high-strength insulating material, 

which can not only effectively isolate the internal electrically charged parts and prevent electric shock accidents, 

but also resist the erosion of dust and moisture in the industrial environment and guarantee the normal work of the internal electrical components. 

The connection terminals are well-designed to facilitate connection with external circuits and ensure the stability of signal transmission.

Design features: The overall design is compact and small, with a net width of only 9mm, a net depth (length) of 78.5mm, 

a net height of 90mm, and a weight of about 0.035kg. 

This compact design makes it easy to be installed in electrical control cabinets where space is limited, and does not take up too much valuable space. 

The mounting method adopts side mounting, 

through the specific mounting structure and the main equipment close combination, the installation process is simple and fast, 

and after installation, high stability, not easy to loosen. 

At the same time, its protection level reaches IP20, which can effectively prevent foreign objects with a diameter of more than 12mm 

and fingers from touching the internal electrically charged parts, and to a certain extent protects the safety of the use process.


Electrical performance parameters

Rated Insulation Voltage and Rated Impulse Withstand Voltage: 

The rated insulation voltage (Ui) is as high as 690V, which means that it is able to maintain good insulation performance in a higher voltage environment to 

ensure the safety of the electrical system. Rated impulse withstand voltage (Uimp) for auxiliary circuits 6kV, with a strong resistance to voltage shocks, 

can effectively deal with the industrial field may appear in the instantaneous overvoltage and other abnormalities, 

to protect the auxiliary contact itself and the electrical equipment connected to the safe operation of the auxiliary contact.

Rated operating current and performance under different load types: 

Under different load types, HK1-11 auxiliary contacts have different rated operating currents. 

Under alternating current loads (AC - 15), the rated operating current (Ie) is 6A at 24V, 4A at 240V, 1A at 690V, and 3A at 380/400V. 

Under direct current loads (DC - 13), Ie is 2A at 24V, 0.55A at 125V, 0.27A at 250V, 0.15A at 440V, and 0.15A at 600V. 

These rated operating current parameters for different load types enable them to be widely used in a variety 

of complex industrial electrical environments to meet the control needs of different electrical equipment.

Electrical and Mechanical Durability: Electrical and mechanical durability is up to 100000 cycles. 

This means that the electrical and mechanical properties of the HK1-11 auxiliary contact can remain stable over a long period of frequent use, 

and will not deteriorate or wear out as a result of frequent on/off operations, which greatly reduces the frequency of equipment maintenance and replacement, 

lowers the operating costs of industrial production, and improves the reliability and stability of the production system.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection