Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB HK1 - 11 Auxiliary Contacts Critical Connectors for Industrial Electrical Systems
    ❤ Add to collection
  • ABB HK1 - 11 Auxiliary Contacts Critical Connectors for Industrial Electrical Systems

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    Product positioning and function: HK1-11 auxiliary contacts are designed for use with ABB related electrical equipment, 

    mainly used to reflect the working status of the main contacts of switches and contactors in the main circuit, 

    and transmit these status signals to other parts of the control system to realize remote monitoring, signal feedback and logic control of the circuit, etc. 

    For example, in motor control circuits, the main contacts of contactors can be closed by means of HK1-11 auxiliary contacts. 

    For example, in the motor control circuit, through the HK1 - 11 auxiliary contact, 

    the closing or disconnecting status of the main contact of the contactor can be transmitted to the control center, 

    so that the operator can know the running status of the motor in real time.

    Product family affiliation: It is a member of the ABB electrical equipment accessory system and is closely aligned with 

    ABB's manual motor starters (models MS116, MS132, MS165, etc.). 

    This close correlation ensures seamless collaboration and optimal performance of the components in the entire electrical system.


    • ¥18519.00
      ¥5817.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:18.090KG
    • Quantity:
    • (Inventory: 99999)
Description

Product positioning and function: HK1-11 auxiliary contacts are designed for use with ABB related electrical equipment, 

mainly used to reflect the working status of the main contacts of switches and contactors in the main circuit, 

and transmit these status signals to other parts of the control system to realize remote monitoring, signal feedback and logic control of the circuit, etc. 

For example, in motor control circuits, the main contacts of contactors can be closed by means of HK1-11 auxiliary contacts. 

For example, in the motor control circuit, through the HK1 - 11 auxiliary contact, 

the closing or disconnecting status of the main contact of the contactor can be transmitted to the control center, 

so that the operator can know the running status of the motor in real time.

Product family affiliation: It is a member of the ABB electrical equipment accessory system and is closely aligned with 

ABB's manual motor starters (models MS116, MS132, MS165, etc.). 

This close correlation ensures seamless collaboration and optimal performance of the components in the entire electrical system.



ABB HK1 - 11 Auxiliary Contacts: Critical Connectors for Industrial Electrical Systems

Product Basics Overview

Product positioning and function: HK1-11 auxiliary contacts are designed for use with ABB related electrical equipment, 

mainly used to reflect the working status of the main contacts of switches and contactors in the main circuit, 

and transmit these status signals to other parts of the control system to realize remote monitoring, signal feedback and logic control of the circuit, etc. 

For example, in motor control circuits, the main contacts of contactors can be closed by means of HK1-11 auxiliary contacts. 

For example, in the motor control circuit, through the HK1 - 11 auxiliary contact, 

the closing or disconnecting status of the main contact of the contactor can be transmitted to the control center, 

so that the operator can know the running status of the motor in real time.

Product family affiliation: It is a member of the ABB electrical equipment accessory system and is closely aligned with 

ABB's manual motor starters (models MS116, MS132, MS165, etc.). 

This close correlation ensures seamless collaboration and optimal performance of the components in the entire electrical system.


Product structure and design features

Structure: It is mainly composed of contacts, springs, insulating shells and connecting terminals. 

Contacts as the core components, made of high quality conductive materials, such as silver alloy, 

with good electrical conductivity and anti-melting performance, in the frequent on and off operation, 

can stably transfer the current to reduce the contact erosion, prolong the service life. 

The spring provides power for the action of the contact to ensure that the auxiliary contact can respond quickly and accurately 

when the main contact state changes. The insulating shell is made of high-strength insulating material, 

which can not only effectively isolate the internal electrically charged parts and prevent electric shock accidents, 

but also resist the erosion of dust and moisture in the industrial environment and guarantee the normal work of the internal electrical components. 

The connection terminals are well-designed to facilitate connection with external circuits and ensure the stability of signal transmission.

Design features: The overall design is compact and small, with a net width of only 9mm, a net depth (length) of 78.5mm, 

a net height of 90mm, and a weight of about 0.035kg. 

This compact design makes it easy to be installed in electrical control cabinets where space is limited, and does not take up too much valuable space. 

The mounting method adopts side mounting, 

through the specific mounting structure and the main equipment close combination, the installation process is simple and fast, 

and after installation, high stability, not easy to loosen. 

At the same time, its protection level reaches IP20, which can effectively prevent foreign objects with a diameter of more than 12mm 

and fingers from touching the internal electrically charged parts, and to a certain extent protects the safety of the use process.


Electrical performance parameters

Rated Insulation Voltage and Rated Impulse Withstand Voltage: 

The rated insulation voltage (Ui) is as high as 690V, which means that it is able to maintain good insulation performance in a higher voltage environment to 

ensure the safety of the electrical system. Rated impulse withstand voltage (Uimp) for auxiliary circuits 6kV, with a strong resistance to voltage shocks, 

can effectively deal with the industrial field may appear in the instantaneous overvoltage and other abnormalities, 

to protect the auxiliary contact itself and the electrical equipment connected to the safe operation of the auxiliary contact.

Rated operating current and performance under different load types: 

Under different load types, HK1-11 auxiliary contacts have different rated operating currents. 

Under alternating current loads (AC - 15), the rated operating current (Ie) is 6A at 24V, 4A at 240V, 1A at 690V, and 3A at 380/400V. 

Under direct current loads (DC - 13), Ie is 2A at 24V, 0.55A at 125V, 0.27A at 250V, 0.15A at 440V, and 0.15A at 600V. 

These rated operating current parameters for different load types enable them to be widely used in a variety 

of complex industrial electrical environments to meet the control needs of different electrical equipment.

Electrical and Mechanical Durability: Electrical and mechanical durability is up to 100000 cycles. 

This means that the electrical and mechanical properties of the HK1-11 auxiliary contact can remain stable over a long period of frequent use, 

and will not deteriorate or wear out as a result of frequent on/off operations, which greatly reduces the frequency of equipment maintenance and replacement, 

lowers the operating costs of industrial production, and improves the reliability and stability of the production system.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials