Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB NTU-7A9/M1 Isolated Analog Input Module
    ❤ Add to collection
  • ABB NTU-7A9/M1 Isolated Analog Input Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    NTU-7A9/M1 Isolated Analog Input Module
    • ¥2917.00
      ¥12996.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
NTU-7A9/M1 Isolated Analog Input Module

ABB NTU-7A9/M1 Isolated Analog Input Module

Basic Information

Model and Name: ABB NTU - 7A9/M1 Isolated Analog Input Module, ‘NTU - 7A9/M1’ is the product model number used to differentiate it in the ABB product line. This is an isolated analogue input module, mainly used in industrial automation control systems, the external analogue signal is isolated and processed and then input to the control system, to ensure the accuracy of the signal and the safety of the system.

Family: Belongs to the ABB industrial automation control module series. In this series, there are other types of input modules (such as digital input modules), output modules, communication modules, etc., which cooperate with each other to form a complete industrial automation control system.

Application Scene Association: Widely used in industrial sites, such as factory automation production lines, process control systems (chemical, pharmaceutical, electric power and other industries), intelligent building systems (for environmental monitoring, etc.), for receiving and processing analogue signals, like temperature sensors, pressure sensors, flow sensors, and other equipment output signals.

Functional features

Analogue signal input function

Multiple Input Channels: Usually has multiple analogue input channels, these channels can receive multiple analogue signals at the same time. The number of channels may vary depending on the specific configuration of the product, e.g. there may be 4-channel, 8-channel, etc. configurations. This makes it possible to collect signals from multiple sensors at the same time, facilitating the monitoring of multiple physical quantities, such as the simultaneous collection of multiple analogue signals such as temperature, pressure, liquid level, etc. around a chemical reactor.

Signal type compatibility: It is compatible with a wide range of analogue input signals, including voltage signals (e.g. 0 - 5V, 0 - 10V, etc.) and current signals (e.g. 0 - 20mA, 4 - 20mA, etc.). This compatibility allows it to be connected to a wide range of common industrial sensors, as different sensors may output different types of analogue signals depending on their principle and design.

Highly accurate signal acquisition: It has a high signal acquisition accuracy and is capable of accurately acquiring the value of an analogue signal. The accuracy may be in the range of ±0.1% - ±0.5% for voltage signals and ±0.2% - ±0.6% for current signals, depending on the design and performance level of the product, which ensures accurate measurement of industrial process parameters.

Signal Isolation Functions

Galvanic isolation: provides powerful galvanic isolation between the input analogue signal and the internal circuitry. The isolation voltage levels are high, typically up to several thousand volts, e.g. between 1500V - 3000V AC. This effectively prevents external electrical interference (such as electromagnetic interference from industrial sites, interference generated by high-voltage equipment, etc.) from affecting the internal circuitry, and also avoids damage to external equipment that may be caused by failure of the internal circuitry, which improves the safety and reliability of the system.

Signal isolation methods: the use of appropriate isolation technology, such as optocoupler isolation or transformer isolation. These isolation methods can effectively cut off electrical connections and prevent crosstalk between signals while ensuring signal transmission. For example, optocoupler isolation transmits analogue signals through optical signals, making the input signals and internal circuits electrically completely isolated from each other's potential difference.

Signal Processing and Transmission Functions

Signal conditioning function: The input analogue signal is conditioned, including signal amplification, filtering and other operations. For weak analogue signals, appropriate amplification can be performed so that they can be effectively identified and processed by the system. At the same time, noise and interference components in the signal can be removed by filtering to improve the quality of the signal. For example, for sensor signals containing high-frequency noise, a purer signal that represents the actual physical quantity can be obtained through filtering.

Signal conversion and transmission formats: The processed analogue signals are converted into a format suitable for transmission in industrial communication networks, e.g. the analogue signals are digitised and transmitted to the host controller or other control devices via specific industrial communication protocols (e.g. Profibus, Modbus, etc.). This ensures that signals can be transmitted accurately and efficiently between different devices and systems for centralised control and management.

Technical Parameters

Electrical parameters

Working voltage range: The working voltage is generally DC voltage, the range may be around 18V - 30V DC, which can adapt to the common power supply situation in industrial sites and ensure that the equipment can work stably under different power conditions.

Input Signal Range (Voltage / Current): As mentioned earlier, it is capable of receiving a wide range of voltage and current signals. Voltage signals may include 0-5V, 0-10V, etc., and current signals may include 0-20mA, 4-20mA, etc. These ranges cover most of the industrial sensors. These ranges cover the output signal range of most industrial sensors.

Power Consumption: Power consumption is low, usually between a few watts and a dozen watts, depending on the operating condition of the device (e.g. number of channels in use, complexity of signal processing, etc.) and the design of the device. The low power consumption design helps to run stably for a long time in the industrial environment, and it can reduce the heat generation of the equipment and improve the reliability of the equipment.

Performance Parameters

Acquisition accuracy (voltage/current): The acquisition accuracy may range from ±0.1% - ±0.5% for voltage signals and ±0.2% - ±0.6% for current signals. In addition, there may be performance indicators such as resolution, e.g. for analogue-to-digital converted signals the resolution may be 12 - 16 bits, which determines the minimum amount of signal variation that can be resolved.

Number of Input Channels and Configuration: The number of channels varies from product to product, and may be configured in 4-channel, 8-channel, and other configurations. The channels can be configured either independently or in groups, depending on the product design. Independent channel configurations allow each channel to be set up and controlled individually, while grouped configurations make it easy to operate a group of related channels in a uniform manner.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured