THQB2140GFEP | General Electric 40 Amp 30 mA Ground Fault (GFEP) Breaker
Product Description P/N: THQB2140GFEP Description / Specifications Description The THQB2140GFEP is a GE 40 Amp 30 mA Ground Fault (GFEP) Breaker designed for use in GE panelboards. It features a tin-plated copper stab for a durable, corrosion-resistant connection, ensuring reliability over its operational life. This breaker is part of the THQB GFCI family, identified by the model number THQB2140GFEP. It is configured with 2 poles, suitable for 240 Volt applications with a 5 mA trip sensitivity.
The dimensions of the THQB2140GFEP are 3.25 inches in height, 2 inches in width, and 3 inches in length, making it compact and suitable for various panelboard installations. It utilizes a bolt-on connection type and operates on a single-phase system with an interrupting rating of 10,000 Amperes. Technical Specifications Part Number THQB2140GFEP Manufacturer General Electric Sub-Category Molded Case Family Q-Line Type THQB Voltage 240 V Amperage 40 A Phase 1 Protection Thermal Magnetic Poles 2 Functions LI - Long-Time and Instantaneous Connection Bolt-On AIC Rating 10kA @ 240V Information About THQB2140GFEP
The THQB2140GFEP is a 40 Amp, 30 mA Ground Fault (GFEP) Circuit Breaker manufactured by General Electric, designed specifically for use in GE panelboards. Featuring a tin-plated copper stab, it ensures a durable, corrosion-resistant connection, essential for maintaining reliability over its operational lifespan. This breaker belongs to the THQB GFCI family and is identified by the model number THQB2140GFEP. It is configured with 2 poles and operates at 240 Volts. The breaker is equipped with a sensitive 5 mA trip setting, designed to detect ground faults promptly to mitigate electrical hazards.
Physically, the THQB2140GFEP measures 3.25 inches in height, 2 inches in width, and 3 inches in length, making it compact and suitable for installation in various panelboard configurations. It utilizes a bolt-on connection type, ensuring secure attachment within the panelboard. Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions.
IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.
Compatibility
ƒ Compatible with any Series 90-30 CPU except IC693CPU321 and IC693CPU340. Configuration size is limited for CPU311/313/331, as described on the next page.
ƒ Requires release 8.0 CPU firmware. The latest Release 10 is recommended, if available for the particular CPU.
ƒ Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 plus the appropriate service pack or special (or a version later than 3.0).
ƒ Not compatible with the VersaPro™, Control, or Logicmaster™ programming software.
ƒ The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module. New Features The Series 90-30 DeviceNet Master Module allows a Series 90-30 PLC to send and receive I/O data from a DeviceNet network.
Module features include:
ƒ Support for all standard data rates (125K, 250K, 500K)
ƒ Support for 255 bytes input data transfer and 255 bytes output data transfer per slave
ƒ Support for 3972 bytes of input data transfer and 3972 bytes of output data transfer per master
ƒ Support for two I/O connections per Slave - Typically one connection is used for Polled and the other is used for Strobe, Cyclic, or COS
ƒ Support for Poll, Strobe, Cyclic and COS I/O Connections, Fragmented I/O and Explicit Messaging
ƒ Support for Unconnected Message Manager (UCMM) with 1 proxy connection per slave device
ƒ Support for configuration of the global scan rate
ƒ Support for configuration of update rates for Poll and COS/Cyclic on a connection basis
ƒ Support for PLC-application initiated explicit messaging via a COMMREQ
ƒ Master can be configured to operate as a slave simultaneously with master operation
ƒ Configurable fault behavior on loss of communication
ƒ Reports loss or reestablishment of communication with slaves in PLC fault table (configurable)
ƒ Support for 64 network device status bits (note: the bit for the master itself is always zero)
ƒ Firmware update via service port on module
email:1583694102@qq.com