Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

AB Stratix 8000 and 8300 Ethernet Managed Switches

来源: | 作者:FAN | 发布时间 :2025-04-21 | 578 次浏览: | Share:

AB Stratix 8000 and 8300 Ethernet Managed Switches

Product Overview: The Stratix 8000 and 8300 Ethernet Managed Switches are designed for use in harsh industrial environments, 

connecting servers, routers, PLCs, and other network devices. 

They are available in models such as the 1783-MS06T (4 10/100BASE-T Ethernet ports and 2 dual-purpose ports) and 1783-MS10T for the Stratix 8000 series,

and the 1783-RMS06T and 1783-RMS10T for the Stratix 8300 series. 

There are also expansion modules 1783-MX08T (8 10/100BASE-T copper Ethernet ports), 1783-MX08F (8 100BASE-FX fibre-optic Ethernet ports), 

and a variety of SFP modules.

Preparation for installation: Before installation, make sure that the installation environment meets the requirements, 

the ambient temperature is between -40°C and 60°C, and there is enough space around the equipment to ensure that the airflow is not blocked. 

Prepare tools such as a ratcheting torque screwdriver and specific copper grounding wire.


Installation Procedure:

Connection of expansion modules (optional): 1 - 2 expansion modules can be installed, with specific combination limitations, 

remove the side panels before installing and fixing.

Mounting the switch: DIN rail, wall or panel mounting is available; DIN rail mounting requires attention to grounding and DIN rail type; 

wall or panel mounting requires specific bolts and washers.

Mounting SFP Modules (optional): wear an ESD wrist strap during operation and be aware of module compatibility.

Grounding: Use 5.3 mm 2 (10 AWG) grounded copper wire to connect to the ground screw on the front panel of the switch.


Connecting the DC Power Supply: The power supply must comply with the CE Low Voltage Directive and UL limits, 

observing positive and negative polarity and torque requirements when connecting.

Connecting the power supply and relay connectors: Insert the connectors and tighten the screws, taking care to isolate 

the voltages if more than one power supply is used.

Connecting external alarms (optional): connect up to two external alarm devices, use specific wires and pay attention to voltage and torque requirements.


Configuration Management:

Express Setup: Used to set the initial IP address, requires specific device and network configuration.

Configuration Management Methods: Configuration and management can be performed through the Device Manager web interface, 

RSLogix 5000 software, and other methods.

Reset Operation: The switch can be restored to the factory default settings, after which it needs to be reconfigured.

Troubleshooting: Faults such as POST failure, port connection problems, etc. can be determined by the status indicators on the front panel of the switch. 

Troubleshooting can also be assisted by obtaining statistical information through the browser interface, command line interface, or SNMP workstation.


Product Specifications

Electrical specifications: The input voltage range is 18-60V DC and the maximum input current is 1A, 

which can adapt to power fluctuation within a certain range and provide power protection for the stable operation of the switch. 

The alarm relay is rated at 30V DC max. and 1A max. and can be used to connect external alarm devices to issue an alarm in time 

when the system is abnormal. For isolation voltage, the switch base and expansion modules have specific isolation requirements between different ports, 

such as 75V (continuous) basic insulation type between DC power port and ground, 

Ethernet port, alarm port, and between Ethernet port and expansion backplane, and have been tested at 1000V AC 60s, 

which guarantees electrical isolation between different circuits and improves the system security .

Physical Specifications: The dimensions of the switches and expansion modules are clearly defined, 

taking the 1783-MS10T and 1783-MX08T as examples, which facilitates space planning and layout during equipment installation. 

A variety of port types, including 10/100BASE-T, 10/100/1000BASE-T copper ports and SFP module slots, 

as well as 100BASE-FX fibre-optic ports (only available on the 1783-MX08F expansion module), 

are available to meet the connectivity needs of different devices. 

The connecting wires have specific specifications, including IEC 60603-7-compliant RJ45 connectors and at least Category 5e cables for Ethernet connections, 

0.5-0.8 mm 2 (20-18 AWG) copper wires for DC power and alarm connections, and 3.3-5.3 mm 2 (12-10 AWG) copper wires for functional ground connections, 

ensuring the reliability of the electrical connections. Ensures reliable electrical connections.

Environmental specifications: Operating temperature range of - 40°C to 60°C and non-operating temperature range of - 40°C to 85°C provide a wide range 

of temperatures for stable operation in a variety of climatic and industrial environments. 

Relative humidity requirements of 5% to 95% non-condensing, even in humid environments. 

The product is IP20 rated, which provides a degree of protection for the internal circuitry by preventing the ingress of solid foreign objects larger than 12mm. 

There are also standards for vibration and shock, such as 2g @ 10-500Hz for vibration, 20g for operating shock, and 30g for non-operating shock, 

providing strong resistance to environmental interference.


Performance Features

Port auto-negotiation and self-adaptation: The ports are equipped with the functions of auto-negotiation of link speed (10 Mbps or 100 Mbps) 

and duplex setting (full-duplex or half-duplex), which can automatically match the optimal network connection parameters 

with the connected devices without manual configuration, thus improving the convenience and compatibility of device connection. 

Some models of dual-purpose ports, in the SFP module port and RJ45 port at the same time there is a connection, the SFP module port has priority, 

this design makes the network connection more flexible, according to the actual needs of the choice of different connection methods.

Multiple Configuration and Management Methods: Provides multiple configuration and management methods, including Device Manager web interface, 

RSLogix 5000 software, Cisco Network Assistant, Command Line Interface (CLI) and SNMP management application. 

Users can choose the appropriate way according to their own needs and technical level, which is convenient for initial setup, 

daily management and troubleshooting of the switch. The Express Setup function allows users to quickly set up the initial IP address of the switch, 

enabling the switch to be connected to the network for subsequent management and simplifying the configuration process during initial use.

Fault Detection and Indication: The status indicators on the front panel can visually reflect the working status of the switch, 

including power status (PWR A, PWR B indicators), EtherNet/IP module status (EIP Mod indicator), network status (EIP Net indicator), 

setup status (Setup indicator), and port status (Port indicator, etc.). 

By observing the colours and flashing status of the indicators, users can quickly determine whether the switch is working properly and find 

and locate faults in time, such as POST failure, port connection problems, etc. 

The switch will perform POST at startup. The switch will perform POST (power-on self-test) at startup, if POST fails, the system status indicator will turn red, 

which indicates that there is a fault in the device and it needs to be checked and repaired accordingly.

ALLEN-BRADLEY STRATIX 8000 INSTALLATION INSTRUCTIONS MANUAL Pdf ...

  • WESTINGHOUSE 5X00070G01 Ovation Module
  • Westinghouse 5X00605G01 Control Module
  • WESTINGHOUSE 5X00241G02 Ovation System Communication Module
  • WESTINGHOUSE 5X00226G03 Ovation Module
  • Westinghouse ZX345Q Control System
  • WESTINGHOUSE ST24B3 Temperature Transmitter
  • WESTINGHOUSE AID-1 Industrial Keyboard
  • Westinghouse 5X00241G01 Control Module
  • WESTINGHOUSE 5X00226G02 Ovation Controller Base Module
  • WESTINGHOUSE 5X00119G01 Ovation Module
  • Westinghouse 5X00105G14 Control Module
  • WESTINGHOUSE 5X00105G01 Ovation System Base Module
  • WESTINGHOUSE 5X00058G01 Ovation Controller
  • Westinghouse 5A26391H24 Control Module
  • WESTINGHOUSE 4D33942G01 Ovation I/O Communication Module
  • WESTINGHOUSE 3A99158G01 Ovation I/O Module
  • WESTINGHOUSE 3A99200G01 Control Module
  • WESTINGHOUSE 3A99132G02 Ovation System Power Module
  • WESTINGHOUSE 3A99132G01 Ovation Interface Module
  • WESTINGHOUSE 1X00416H01 Control Module
  • WESTINGHOUSE 1X00024H01 Ovation System Interface Module
  • WESTINGHOUSE 1C31227G02 Ovation I/O Module
  • Westinghouse 1C31194G03 Control Module
  • WESTINGHOUSE 1C31194G02 Ovation Controller Module
  • WESTINGHOUSE 1C31194G01 Ovation Controller Module
  • WESTINGHOUSE 1C31189G01 Control I O Module
  • WESTINGHOUSE 1C31179G02 Ovation Processor Module
  • WESTINGHOUSE 1C31164G02 Ovation Relay Output Module
  • Westinghouse 1C31161G02 RTD Input Module
  • WESTINGHOUSE 1C31150G01 Ovation DCS I/O Controller Module
  • WESTINGHOUSE 1C31113G02 Ovation Analog Input Module
  • WESTINGHOUSE 1C31129G03 Control Module
  • WESTINGHOUSE 1C31122G01 Process Controller | Ovation DCS Control Module
  • WESTINGHOUSE 1C31113G02 Ovation Analog Input Module
  • WESTINGHOUSE 1B30023H02 Control Module
  • WESTINGHOUSE 1B30035H01 Turbine Control System Module
  • WIDAP UFW30.156 6K8J175W0823 Power Resistor Technical Profile
  • WINGREEN IPB PCB V2.0_A01 03ZSTL6-00-201-RS Industrial Power Board
  • WINGREEN CANopen_ADAPTER V5.0_A01 03ZSTI-00-501-RS Module
  • WINGREEN PUIM V2.0 034STM4-00-200-RS Power Interface Module
  • WINGREEN DUDT_DETECTION_V2.0_A01 03ZSTJ0-00-201-RS Detection Control Board
  • WINGREEN LAIB V3.0_A00 034STN1-00-300-RS Embedded Industrial Motherboard
  • WINGREEN FAN_DETECTION V1.0_A05 03ZSTJ3-00-105Fan Monitoring Module
  • WINGREEN LAIB V3.0_A00 034STN1-01-300-RS Interface Board
  • WINGREEN ATKB_V5.0_A01 03ZSTI4-00-501 Industrial Control Keyboard Module
  • WINGREEN ATKB_V5.0_A01 03ZSTI4-01-501 Industrial Motherboard | Embedded Control Board
  • WINGREEN FPB_V3.0_A01 03ZSTJ1-00-301-RS Fieldbus Processor
  • WINGREEN DSPB_V4.0_A02 03ZSTI7-00-402-RS Digital Processing Board
  • WOHNER 31110 Cylindrical Fuse Holder
  • WOODHEAD APPLICOM PCI4000 PCI Communication Card Industrial DeviceNet CAN Bus Interface
  • Woodward 8440-1706 Industrial Control System Module
  • Woodward 8440-2052 H Synchronizer Load Share Module
  • Baldor KPD-TS12C-30E 12.1" Color TFT Touch Screen Ethernet HMI
  • Baldor KPD-TS10C-30E 10" Color TFT Touch Screen Operator Interface with Serial and Ethernet Interfaces
  • Baldor KPD-TS05C-30E 5.6" Color TFT Touch Screen with Serial and Ethernet Interface
  • Baldor KPD-TS05C-30 5.6 Inch Color TFT Touch Screen Serial Interface
  • Baldor KPD-TS05M-10 5.6" Monochrome Touch Screen Serial Interface HMI
  • Baldor KPD-TS03M-10 Monochrome Touch Screen Operator Interface
  • Baldor KPD-KG420-30 4x20 Graphic Display with 12 Function Keys - Serial Interface
  • Baldor KPD-KG420-20 4x20 Character Graphic Display Serial Interface
  • WOODWARD EASYGEN-3200-5 8440-1992 A Genset Controller
  • WOODWARD PEAK200-HVAC 8200-1501 C Version | Industrial Building Automation Controller
  • Woodward 8440-2052 easyGEN-3200 Genset Control Power Management
  • Woodward 8237-1246 + 5437-1119 Control System Module
  • WOODWARD SPM-D11 8440-1703 Overspeed Protection System Module
  • WOODWARD 8237-1369 Governor Control Module
  • Woodward 8237-1600 Digital Control Module
  • WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-0000 3522-1004 Industrial Control Module
  • WOODWARD 8200-1302 Genset Controller
  • Woodward 8901-457 Speed Control Module
  • WOODWARD 5501-465 Control Module
  • Woodward 5448-890 SPM-D10 Digital Control Module
  • WOODWARD 5437-1067A Turbine Governor Actuator
  • Woodward 8440-1666 B Digital Control Module
  • WOODWARD 8440-1706 A SPM-D11 Synchronous Phase Modulator Module
  • WOODWARD 5466-425 Programmable Automation Controller (PAC)
  • WOODWARD 5466-318- Industrial Gas Turbine Control Module
  • WOODWARD 5453-277 Digital Control Module
  • WOODWARD 5453-203 Digital Governor Control Module
  • WOODWARD 9907-1106 Pressure Converter
  • WOODWARD 5233-2089 Professional Industrial Control System Module
  • WOODWARD 9907-147 Power outage tripping overspeed protection system
  • WOODWARD 8237-1600 Digital Speed Control System
  • WOODWARD 8402-319 8402-119 microprocessor speed controller
  • Woodward 8237-1006 Digital Governor
  • WOODWARD 5501-471 Communication Module
  • WOODWARD 5466-258 Input/Output Module
  • WOODWARD 5501-467 Multi Protocol Communication Gateway and I/O Expansion Module
  • WOODWARD 5501-470 Digital microprocessor controller module
  • WOODWARD 9907-1200 Digital Governor
  • WOODWARD 8444-1067 High Performance Digital Microprocessor Controller Module
  • WOODWARD 8446-1019 Integrated Gas Engine Electronic Control System
  • WOODWARD 9907-162 Digital Engine Governor
  • WOODWARD 5466-316 Simulation Combination Module
  • WOODWARD 5464-414 Digital Speaker Sensor Module
  • XANTREX XFR40-70 DC power supply
  • XP POWER F8B6A4A6A6 power module
  • XP POWER F8B6D4A3G3 power supply
  • XYCOM XVME-674 VMEbus Single Slot CPU/Processor Module
  • XYCOM XVME-957 Circuit Board
  • XYCOM XVME-976 PC board computer
  • XYCOM XVME-530 8-Channel Isolated Analog Output Module
  • XYCOM Proto XVME-085 Bus Module
  • YAMAHA RCX40 4-AXIS ROBOT CONTROLLER
  • YAMATAKE EST0240Z05WBX00 touch screen display
  • YAMATAKE HD-CAOBS00 flowmeter
  • HIMA X-COM 01 Communication Module
  • HIMA HIMax X-AO 16 01 Analog Output Module
  • HIMA X-AI3251 Analog Input Module
  • HIMA X-DO3251 Digital Output Module
  • HIMA X-DI3202 Digital Input Module
  • HIMA X-DI6451 Digital Input Module
  • YASKAWA USAHEM-02-TE53 AC servo motor
  • Yaskawa JZNC-XPP02B Teaching Programmer
  • YASKAWA CACR-SR07BE12M servo drive
  • YASKAWA JAMSC-B2732V Advanced Drive Controller
  • YASKAWA JGSM-06 Controller
  • YASKAWA PCCF-H64MS 64MB Industrial Memory Module
  • YASKAWA CACR-02-TE1K servo driver
  • YASKAWA JAPMC-IQ2303 Controller Module
  • YASKAWA DDSCR-R84H Controller
  • YASKAWA JANCD-XTU01B circuit board
  • YASKAWA JANCD-XIO01 High Performance PC Input/Output (I/O) Board
  • YASKAWA JACP-317800 servo drive
  • XYCOM 120974 - Circuit Board
  • XYCOM 99298-200 - PC Control Card 99207A-001
  • XYCOM 99298-266 - CPU Board
  • XYCOM 99311-001 - Screen Display Ribbon Cable