Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB Electrical 1SAZ211201R1009 Thermal Overload Relay
    ❤ Add to collection
  • ABB Electrical 1SAZ211201R1009 Thermal Overload Relay

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical 1SAZ211201R1009 Thermal Overload Relay
    • ¥666.00
      ¥9134.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.440KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical 1SAZ211201R1009 Thermal Overload Relay

ABB Electrical 1SAZ211201R1009 Thermal Overload Relay

Basic information

Meaning of model number: ‘1SAZ211201R1009’ is a specific model number assigned by ABB for this thermal overload relay, in which different combinations of characters and numbers may represent specific functions, specifications, design versions and other information, in order to facilitate the user to accurately identify and select the model.

Series: This relay belongs to ABB's thermal overload relay series, which is designed for overload protection of electric motors and other electrical equipment, and has a wide range of specifications and functional features to meet different application scenarios and load requirements.

Technical data

Current range: This type of thermal overload relay is usually suitable for smaller current overload protection, generally used with motors with smaller rated current, the specific adaptable current range should refer to the detailed product manual, but from the series of products, it is mostly a few amperes to tens of amperes, for example, similar to the model number 1SAZ211201R1017 corresponds to the TA25DU-0.63 thermal overload relay, whose rated current is 0.63 amps. For example, a similar model 1SAZ211201R1017 corresponds to TA25DU-0.63 thermal overload relay, which has a rated current of 0.63A, while 1SAZ211201R1021 corresponds to TA25DU-1.0 thermal overload relay, which has a rated current of 1.0A.

Voltage specification: the coil voltage and the voltage that the contacts can withstand and other parameters should be determined according to the specific product information, in general, the coil voltage of ABB thermal overload relay has a variety of standard specifications to choose from, such as common AC 220V, 380V, etc., in order to adapt to different control circuit voltage levels.

Tripping level: It has specific tripping level, and the common tripping level is 10, which means that when the motor overload current reaches 10 times of the set value, the thermal overload relay will act in the specified time to cut off the circuit, so as to effectively protect the motor from the damage of prolonged overload current.

Functional features

Overload protection function: by detecting the current in the main circuit of the motor, when the current exceeds the set overload protection value, the bimetal inside the thermal overload relay will be bent and deformed due to the heat generated by the overload current, which will push the contacts to operate and cut off the power circuit of the motor, preventing the damage of the motor due to the prolonged overload operation, protecting the insulation of the windings and other key parts of the motor, and prolonging the service life of the motor. Protect the insulation of motor winding and other key components, prolong the service life of the motor.

Phase loss protection: with phase loss protection function, when any one of the three-phase power supply of the motor is missing or the voltage is too low and other faults, the thermal overload relay can detect the imbalance of the current in time and trigger the release action in a short time to cut off the power supply to prevent the motor from continuing to run in the state of phase loss which may lead to the burnout, which effectively improves the reliability and safety of the operation of the motor.

Manual/automatic reset function: manual and automatic reset modes are available. In manual reset mode, when the thermal overload relay is deactivated due to overload or other faults, it is necessary to manually operate the reset button to restore the relay to its initial state, reclosing the contacts and turning on the motor power supply; whereas in automatic reset mode, the thermal overload relay can be automatically restored to its normal working state within a certain period of time after the faults are removed, without manual intervention, which is convenient and quick, and can be carried out flexibly according to the specific application needs and maintenance requirements. It is convenient and fast, and can be set flexibly according to the specific application needs and maintenance requirements.

Fields of application

Motor protection: Widely used in a variety of equipment and systems that require motor drive, such as machine tools, conveyor belts, fans, pumps, etc. in industrial production, as well as air conditioning, lifts, automatic doors and other equipment in the commercial and civil fields, to provide reliable overload and phase loss protection for motors, to ensure the normal operation of motors, to reduce the damage to the equipment and downtime due to overload and phase loss faults, to improve production efficiency and equipment reliability. It reduces equipment damage and downtime caused by overload and phase failure, and improves productivity and equipment reliability.

Electrical control system: as an important protection element in the electrical control system, it is used in conjunction with other electrical components such as contactors, circuit breakers, fuses, etc., to build a complete motor control and protection circuit, realise the control functions such as starting, stopping, forward and reverse rotating, and speed regulation of the motor, and cut off the power supply in time when there is a fault, so as to protect the safe and stable operation of the whole electrical system.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection