Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB Electrical 1SBL141001R8810 Auxiliary Block Contactor
    ❤ Add to collection
  • ABB Electrical 1SBL141001R8810 Auxiliary Block Contactor

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical 1SBL141001R8810 Auxiliary Block Contactor
    • ¥1170.00
      ¥3775.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.680KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical 1SBL141001R8810 Auxiliary Block Contactor

ABB Electrical 1SBL141001R8810 Auxiliary Block Contactor

Basic Information

Model No.: 1SBL141001R8810 belongs to ABB A series AC contactor.

Place of origin: Sweden.

Technical Parameters

Voltage: The rated voltage of the control coil is 230 - 240V 50Hz / 240 - 260V 60Hz, and the rated voltage of the contacts can be up to 690V.

Current: The rated operating current of the AC-3 varies at different voltages, e.g. 9A at 220/230/240V and 7A at 690V. The rated current for general use is 25A, and the controllable power varies accordingly at different voltage levels, such as 4kW at 415V and 5.5kW at 690V.

Contact configuration: the main contact is three-pole, the number of normally open contacts is 3, the number of normally closed contacts is 0; the number of auxiliary contacts is 1 normally open, 0 normally closed.

Functional characteristics

Control function: It is mainly used to control the on-off of three-phase AC circuit, and is suitable for all kinds of equipments that need to control three-phase power supply, such as three-phase motor, three-phase heating equipment, and so on. By controlling the energising and de-energising of the coil, the main contact is closed or disconnected, thus realising the control of the load.

Auxiliary Control Expansion: The auxiliary contacts can be used to expand the control functions and realise complex control logics such as forward and reverse motor control, star-delta start control, etc. They can also be used for signal feedback to the control system. They can also be used to provide feedback to the control system on the contactor's engagement and release status for system monitoring and troubleshooting.

Compatibility and Integration: Compatible with other ABB electrical products and common electrical equipment, it can be easily integrated into an electrical control system with main contactors, PLCs, relays, sensors and actuators to perform complex control tasks.

Application Areas

Industrial automation: in automated production lines, it can be used to control the operation of conveyor belt motors, robotic arm motors and other equipment; in machine tool control, it can be used to control cooling pumps, tool feed motors and so on.

Building electrical system: in the three-phase lift control system, it can be used to control the three-phase motor operation of the lift car; in the HVAC system, it can be used to control the starting and stopping of three-phase air-conditioning unit fans, compressors and other equipment, and the switching of operating modes.

Power system automation: It is used for signal processing and control logic in power facilities such as substations, distribution rooms, etc., and cooperates with the main contactor to achieve safety control and condition monitoring of power equipment.

FEATURES

• Process Station with integrated fieldbus  capability  

• 4 high-speed fieldbus lines  

• Supports different fieldbus types, even  simultaneously:  PROFIBUS-DP, up to 12 MBd  Modbus  CAN  Foundation Fieldbus H1 (with LD800  HSE)  

• Easy engineering:  fully integrated in Control Builder F  

• One unified database for field devices  shared by the control level and the Human  System Interface (HSI)  

• Module recognition with factory and operational parameters  

• Comprehensive diagnostics for proactive  maintenance  

• Compact, rugged design  

• Front panel connectors  

• DIN Rail (C-rail) or wall mounting for easy  installation  

• Ambient temperature 0-60 °C (32-140 °F)  with temperature monitoring  

• EMC certification according to EN50082  

• Certification:  CE, NAMUR, CSA, UL, EN61000-6-2.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide