Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB 1SBP260102R1001 XC08L1 Digital I/O Extension Unit
    ❤ Add to collection
  • ABB 1SBP260102R1001 XC08L1 Digital I/O Extension Unit

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    XC08L1 Digital I/O Extension Unit
    Manufacturers
    ABB

    Model(s)
    ABB Advant Controller 31, ABB Advant OCS

    Additional Information
    8 24VDC Configurable I/O, 8 Inputs 0-24V DC 5mA, 8 Outputs 24V DC 0.5A.
    Estimated Shipping Size
      Dimensions: 4.0" x 3.0" x 4.0"
      (10.2 cm x 7.6 cm x 10.2 cm)
      Weight: 0 lbs 6.1 oz (0.2kg )


    Tariff Code: 8538907080


    Country of Origin: Sweden
      Ships from Webster NY, USA

    • ¥4745.00
      ¥58282.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
XC08L1 Digital I/O Extension Unit
Manufacturers
ABB

Model(s)
ABB Advant Controller 31, ABB Advant OCS

Additional Information
8 24VDC Configurable I/O, 8 Inputs 0-24V DC 5mA, 8 Outputs 24V DC 0.5A.
Estimated Shipping Size
  Dimensions: 4.0" x 3.0" x 4.0"
  (10.2 cm x 7.6 cm x 10.2 cm)
  Weight: 0 lbs 6.1 oz (0.2kg )


Tariff Code: 8538907080


Country of Origin: Sweden
  Ships from Webster NY, USA


ABB 1SBP260102R1001 XC08L1 Digital I/O Extension Unit

Basic Information

Model number and naming: The complete model number of this product is 1SBP260102R1001 XC08L1, where 1SBP260102R1001 is the specific model number of the product, and XC08L1 means that the expansion unit belongs to the XC08L1 series, and such a model naming can accurately identify and differentiate between different product models and series.

Country of origin: Sweden.

Dimensions and weight: approx. 10.2 x 7.6 x 10.2 cm, weight 0.2kg.

Performance features

Input and output channels: 8 digital input channels and 8 digital output channels, this relatively balanced configuration of input and output channels can meet the needs of a variety of industrial control scenarios for signal acquisition and device control, can be simultaneously connected to a number of digital sensors and control of a number of digital devices, such as connecting proximity switches, photoelectric sensors and other input devices, as well as controlling relays, solenoid valves, indicator lights and other output devices. Output devices.

Signal parameters: The rated input voltage of the digital input channel ranges from 0 to 24V DC, and the input current is 5mA, which can be adapted to a variety of common digital sensor signals, and can flexibly receive digital input signals of different levels. The output voltage of the digital output channel is 24V DC, and the maximum output current of each channel is 0.5A, which can stably provide drive signals for the connected external devices to ensure the normal operation of the devices, such as providing sufficient drive current for the small solenoid valves to make them open and close normally.

Electrical isolation: electrical isolation technology is used between the input and output channels, the isolation voltage can reach a certain safety standard, effectively preventing the input and output signals from interfering with each other and the propagation of electrical faults, improving the stability and reliability of the system, guaranteeing the stable operation of the equipment in the complex industrial electromagnetic environment, and reducing the risk of malfunctioning and equipment damage caused by signal interference.

Configuration Flexibility: Supporting a variety of configuration modes, users can flexibly configure the functions of the input and output channels according to the actual application requirements, such as setting some channels as input modes for monitoring the status of the equipment, and other channels as output modes for controlling the equipment actions, and achieving different functional configurations through software programming or hardware jumpers to satisfy the personalised requirements of different industrial automation control systems.

Status Indication: Each input and output channel is equipped with an LED indicator, which is used to visually display the working status of the channel, such as the presence or absence of the input signal, the high and low level status of the output signal, etc. It is convenient for the user to quickly understand the operating condition of the module, find and remove the faults in time, reduce the system maintenance cost and downtime, and improve the production efficiency.

Application Fields

Industrial automation: Widely used in various industrial automation production lines, such as automotive manufacturing, electronics manufacturing, food processing and other industries, can achieve the state of the production equipment monitoring, logic control and sequence control and other functions, such as controlling the production line of the conveyor belt, robotic arms, cylinders and other equipment, as well as monitoring the operating state of the equipment and fault signals, to ensure that the production line of efficient and stable operation.

Process control: In the chemical, petroleum, electric power, water treatment and other process industries, it can be used as the extension module of distributed control system (DCS) or programmable logic controller (PLC), for collecting and controlling digital signals on the site, such as monitoring and controlling the switching state of valves, starting and stopping pumps, and alarm signals of temperature and pressure, to ensure the safe, stable and highly efficient operation of the production process.

Intelligent Building: It is suitable for HVAC system, lighting system, water supply and drainage system in intelligent buildings, etc. By cooperating with PLC, DCS and other control systems, it can realise intelligent control and management of various equipments, e.g. controlling the operation status of air-conditioning system according to indoor and outdoor environmental parameters, realising zoning control and timing control of the lighting system, and monitoring the water level and flow rate of water supply and drainage system, etc., so as to improve energy use efficiency and comfort level of the building. Energy efficiency and comfort.

Transportation: In the field of transportation, such as rail transportation, port terminals, etc., it can be used in signal control, equipment monitoring and safety protection, such as controlling the switching of traffic signals and road gates, monitoring the signals of vehicle detection equipment, controlling the actions of cranes, conveyor belts and other equipment to ensure the normal operation and safety management of the transportation system.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide