  • ABB Electrical 1SCA022747R6490 OT400U03 Switch Disconnector
    ❤ Add to collection
  • ABB Electrical 1SCA022747R6490 OT400U03 Switch Disconnector

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical 1SCA022747R6490 OT400U03 Switch Disconnector
    • ¥573.00
      ¥6234.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.320KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical 1SCA022747R6490 OT400U03 Switch Disconnector

ABB Electrical 1SCA022747R6490 OT400U03 Switch Disconnector

Basic Parameters

Rated current: 400A.

Rated voltage: The rated working voltage is 1000V, which is suitable for many common low-voltage distribution systems, such as 380V-415V, 500V, 690V, etc. The rated current is 400A.

Short-circuit withstand current: The short-time withstand current of 15 kA rms for 1 second indicates the ability of the disconnectors to withstand short-circuit faults and ensures a certain degree of electrical stability under short-circuit conditions, providing reliable protection for the system.

Number of poles: 3-pole switch, can meet the isolation needs of three-phase circuits, in the three-phase power system, can cut off or turn on the three-phase power supply at the same time, to ensure the safety of electrical equipment repair and maintenance.

Installation: Adopting the base mounting method, it can be fixed in the electrical cabinet or other suitable positions through normal installation method to ensure the stability and reliability of the installation, which is easy to be integrated and used in all kinds of electrical equipments.

Functional characteristics

Isolation function: Its main function is to reliably isolate the part to be inspected from the power supply when the electrical equipment is being overhauled or maintained, forming an obvious disconnection point to ensure the safety of the overhaulers. When the switch is in the breaking state, it can effectively prevent the power supply from being turned on accidentally, avoiding the danger of electric shock to the maintenance personnel, and providing a safety guarantee for the overhaul and maintenance of electrical equipment.

Operation mode: The front operation mode allows the operator to operate the switch in the front of the switch, which is simple and convenient to operate and easy to master. At the same time, the operating mechanism is located at the end of the switch, which makes the operation more labour-saving and can provide more accurate operation control to ensure the reliable operation of the switch.

Safety: Equipped with padlockable handle and other safety devices, the padlock can further prevent misoperation and ensure that the disconnectors are always kept in a safe breaking state during overhaul or maintenance, increasing the safety and reliability of the equipment. In addition, the unique visual window design enables the operator to visually observe the opening and closing status of the switch without the need for additional inspection tools, improving the convenience and accuracy of operation.

Mechanical Reliability: Adopting high quality materials and advanced manufacturing process, it has high mechanical strength and stability, and can withstand frequent operation and long-term use. Its mechanical durability reaches 16,000 operating cycles, which ensures reliable performance throughout its service life and reduces equipment downtime and maintenance costs due to mechanical failures.

Electrical performance: It has good electrical insulation performance, the rated insulation voltage is 1000V, which can effectively prevent the occurrence of leakage and short-circuit faults. At the same time, the rated shock withstand voltage is 12kV, so that when it suffers from lightning strikes and other over-voltage shock, it can still maintain good insulation performance, protect electrical equipment from damage, and ensure the stable operation of the system.

Application field

Industrial field: Widely used in all kinds of industrial plants, mines, metallurgy, chemical industry and other places in the low-voltage power distribution system, used for motor, transformer, distribution cabinet and other electrical equipment for isolation and protection. For example, in the production line of a factory, when a motor needs to be overhauled, the switch can be used to isolate the motor from the power supply to ensure the safety of the overhaul work.

Commercial buildings: In the electrical systems of commercial buildings such as shopping centres, office buildings, hotels, etc., they can be used as service switches in the distribution circuits of lighting, air conditioning, lifts and other equipment. During the maintenance and overhaul of these equipments, it can reliably cut off the power supply to ensure the safety of the maintenance personnel, and at the same time, it will not affect the normal operation of other equipments.

In the field of power system: in substations, distribution rooms and other power facilities, it can be used as a disconnecting switch on the low-voltage side, which is used to isolate different electrical intervals or equipments, facilitating the overhaul and maintenance of the equipments, and improving the reliability and safety of the power system. In addition, in some small distributed power generation systems, such as solar photovoltaic power generation system, wind power generation system, etc., it can also be used for isolation and protection of the system to ensure the safe operation of power generation equipment and power grid.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide