Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB Electrical 1SVR427036R0000 CP-E 24/20.0 Power Supply Unit
    ❤ Add to collection
  • ABB Electrical 1SVR427036R0000 CP-E 24/20.0 Power Supply Unit

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical 1SVR427036R0000 CP-E 24/20.0 Power Supply Unit
    • ¥1297.00
      ¥9154.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.120KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical 1SVR427036R0000 CP-E 24/20.0 Power Supply Unit

ABB Electrical 1SVR427036R0000 CP-E 24/20.0 Power Supply Unit

Basic Introduction

ABB Electrical 1SVR427036R0000 CP - E 24/20.0 Power Supply Unit is a power supply unit. It is used to convert an incoming power supply (usually AC) into a stable DC output power supply to provide a reliable power supply for other electrical equipment or electronic components.

Functional features

Voltage conversion function

Converts the input voltage to a stable 24V DC output voltage. This DC output is critical for many devices that require a stable DC power supply (e.g. PLCs - Programmable Logic Controllers, sensors, relays, etc.). For example, in industrial automation control systems, providing a stable 24V DC power supply to various control modules and sensors ensures that these devices operate properly and are not affected by power fluctuations.

Output Power Characteristics

Output power of 20.0W determines its ability to provide adequate power support for load devices. The number of devices that can be supported simultaneously can be calculated based on the power requirements of the load devices. For example, for a small sensor with 2W of power, 10 such sensors can theoretically be supported at the same time.

Stability and Reliability

It has high stability and can keep the output voltage stable under a certain range of input voltage fluctuations and load changes. This is achieved through the internal voltage regulator circuit and high-quality electronic components. For example, when the input AC voltage fluctuates within a certain range (e.g. ±10% of the rated input voltage) or when the power demand of the load equipment changes, the output 24V DC voltage fluctuates within a small range, ensuring stable operation of the connected equipment.

Protective Functions

Various protection functions may be provided, such as overcurrent protection, short-circuit protection, and so on. When an overcurrent or short-circuit condition occurs in the output circuit, the power supply unit can automatically cut off the output or take current limiting measures to protect itself and the connected equipment from damage. For example, in the event of a short-circuit fault in the connected equipment, the power supply unit will quickly limit the output current to avoid fire or damage to the equipment due to excessive current.

Input compatibility

It can be adapted to different types of input power supply. Although the exact input voltage range and frequency need to refer to the detailed product specifications, it is generally compatible with common mains voltages (e.g. 110 - 240V AC) and frequencies (e.g. 50/60Hz). This input compatibility allows it to be used in different countries and regions, as long as the local mains power meets its basic requirements.

Technical Parameters

Input parameters

The input voltage range may be a wide interval, e.g. 100 - 240V AC, and the input frequency usually supports 50Hz or 60Hz. the input current varies depending on the output load, but there is a maximum input current limit to ensure safe use.

Output Parameters

The output voltage is 24V DC, the maximum output current can reach a certain value (calculated according to the power, such as 20.0W/24V is about 0.83A), the output ripple voltage is low (the specific ripple coefficient needs to refer to the product manual), which is an important index to measure the stability of the output DC voltage.

Efficiency Parameters

The conversion efficiency of the power supply is an important performance index, which indicates the proportion of input power converted into output power. Higher efficiency means less energy loss. Generally speaking, the conversion efficiency of this power supply unit will be within a certain reasonable range (e.g. 70% - 90%), and the specific value depends on factors such as the load condition and working environment.

Physical parameters

These include external dimensions (length, width, height) and weight. These parameters are very important for installation and layout, e.g. in electrical control cabinets, whether the dimensions can be placed in a reasonable way and whether the weight will affect the installation structure.

Fields of application

Industrial automation

In industrial automation lines, stable power is supplied to various control devices (e.g. PLCs, HMIs, industrial Ethernet switches, etc.) and sensors (e.g. temperature sensors, pressure sensors, etc.). For example, 24V DC power supply for robot controllers, automated testing equipment, etc. in automated production lines in automobile manufacturing plants.

Intelligent Building Systems

In the electrical system of a building, it is used to provide power for intelligent devices (e.g., intelligent lighting controllers, access control system controllers, etc.) and various sensors (e.g., smoke sensors, human body infrared sensors, etc.). For example, in intelligent office buildings to provide power for intelligent control modules for lighting systems and sensors for security monitoring systems.

Communication Devices

In some small communication equipment (e.g., small base stations, network switches, etc.), it is used as an auxiliary power supply unit to provide DC power for the control circuits and some peripheral devices inside the equipment. For example, in network communication equipment within an enterprise, power is supplied to the control chip of a switch and to port indicators, etc.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection