Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB Electrical 2CSF204101R1250 Residual Current Circuit Breaker
    ❤ Add to collection
  • ABB Electrical 2CSF204101R1250 Residual Current Circuit Breaker

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical 2CSF204101R1250 Residual Current Circuit Breaker
    • ¥933.00
      ¥9164.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:6.640KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical 2CSF204101R1250 Residual Current Circuit Breaker

ABB Electrical 2CSF204101R1250 Residual Current Circuit Breaker

Basic Parameters

Rated voltage: 400V, suitable for common low-voltage distribution system, can work stably under this voltage level, provide effective leakage protection for electrical equipment.

Rated current: 25A, can meet the normal operation and protection needs of electrical equipment within a certain power range, such as for the protection of some small and medium power motors, lighting equipment and other branch circuit.

Number of poles: 4 poles, suitable for three-phase four-wire system or three-phase five-wire power supply system including neutral wire, can simultaneously monitor and protect the three-phase fire wire and neutral wire for earth leakage, to ensure the safety and reliability of the system.

Rated leakage action current: 30mA, this sensitivity can be quickly detected and cut off the circuit when a slight leakage occurs, effective protection of personal safety, to prevent electrocution accidents, especially suitable for personal electric shock protection of higher requirements of the place, such as residential, office and so on.

Short-circuit breaking capacity: 1kA, when a short-circuit fault occurs in the circuit, it can reliably cut off the circuit when the short-circuit current reaches 1kA, and protect the electrical equipment and lines from the damage of short-circuit current.

Impact withstand voltage: 4kV, with high impact withstand voltage capacity, can appear in the power grid transient overvoltage, such as lightning impact, etc., can still work normally, to protect the stability of equipment and systems.

Performance characteristics

Leakage protection function: by detecting the residual current in the circuit to determine whether a leakage fault occurs. Under normal circumstances, the three-phase current vector sum in the circuit is zero, zero-sequence current transformer has no induced electromotive force. When leakage occurs, such as human electric shock or equipment insulation damage caused by current leakage, the three-phase current vector sum is no longer zero, the zero sequence current transformer generates inductive electromotive force, triggering the action of the release device, quickly cut off the circuit, thereby protecting personal safety and preventing electrical fires and other accidents.

A variety of leakage current type detection: A type leakage circuit breaker, not only can detect AC residual current, but also can detect pulsating DC residual current, containing electronic equipment such as DC component leakage faults can also be effectively detected and protected, expanding the scope of protection, improve the reliability of protection.

High breaking capacity: short-circuit breaking capacity of 1kA, in the event of a short-circuit fault, can quickly cut off the short-circuit current, limiting the extent of damage to the fault current on the lines and equipment, to ensure the stability and safety of the electrical system, reduce the short-circuit faults triggered by the outage time and the cost of equipment maintenance.

Good environmental adaptability: the working temperature range is - 25℃ to 55℃, it can work normally in a wide temperature range, and adapt to different environmental conditions of the electrical installation places, such as indoor and outdoor distribution boxes, distribution cabinets and so on. In addition, its protection class IP2X can effectively prevent the intrusion of foreign objects, and adapt to certain dust and foreign object protection requirements.

Compact Design and Convenient Installation: DIN rail mounting is adopted, which is convenient and quick to install, saves installation space and time, and facilitates the layout and maintenance in the distribution cabinet or distribution box. Its small external dimensions and compact structure make it suitable for installation in electrical control boxes with limited space.

Selective protection function: It has selective protection function, which can be set according to the actual application requirements. In the multi-level earth leakage protection system, through the reasonable setting of the action time and action current of all levels of earth leakage circuit breakers, to achieve selective cooperation between the upper and lower levels, to ensure that in the event of an earth leakage fault, only the leakage circuit breaker closest to the point of the fault operates, reducing the scope of the blackout, and improving the reliability and continuity of the power supply.

Application field

Industrial field: Widely used in all kinds of industrial plants and workshops for the protection of electrical equipment, such as electric motors on production lines, processing equipment, lighting systems and so on. It can effectively prevent the safety accidents caused by equipment leakage, short-circuit and other faults, ensure the normal progress of industrial production, and improve the service life and operational efficiency of production equipment.

Commercial buildings: In shopping malls, office buildings, hotels and other commercial buildings, it is used to protect lighting circuits, socket circuits, air-conditioning systems, lifts and other electrical equipment. Provide a safe environment for personnel to use electricity, and at the same time to avoid electrical fires caused by leakage faults, to protect the electrical facilities of commercial buildings and property safety.

Residential buildings: It is one of the important protection appliances in the residential distribution box, providing leakage protection for household electrical equipment, such as sockets, lighting fixtures, household appliances and so on. It can effectively prevent personal electric shock accidents caused by leakage of electrical appliances, and protect the life safety of residents and the reliability of home electricity.

Public facilities: including schools, hospitals, gymnasiums, libraries and other public facilities in the electrical system, for the protection of various types of electrical equipment and lighting facilities, to ensure the safety of electricity in public places, to provide people with a safe and comfortable environment for public activities.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide