  • ABB Electrical 2CSF204101R1250 Residual Current Circuit Breaker
    ❤ Add to collection
  • ABB Electrical 2CSF204101R1250 Residual Current Circuit Breaker

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical 2CSF204101R1250 Residual Current Circuit Breaker
    • ¥933.00
      ¥9164.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:6.640KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical 2CSF204101R1250 Residual Current Circuit Breaker

ABB Electrical 2CSF204101R1250 Residual Current Circuit Breaker

Basic Parameters

Rated voltage: 400V, suitable for common low-voltage distribution system, can work stably under this voltage level, provide effective leakage protection for electrical equipment.

Rated current: 25A, can meet the normal operation and protection needs of electrical equipment within a certain power range, such as for the protection of some small and medium power motors, lighting equipment and other branch circuit.

Number of poles: 4 poles, suitable for three-phase four-wire system or three-phase five-wire power supply system including neutral wire, can simultaneously monitor and protect the three-phase fire wire and neutral wire for earth leakage, to ensure the safety and reliability of the system.

Rated leakage action current: 30mA, this sensitivity can be quickly detected and cut off the circuit when a slight leakage occurs, effective protection of personal safety, to prevent electrocution accidents, especially suitable for personal electric shock protection of higher requirements of the place, such as residential, office and so on.

Short-circuit breaking capacity: 1kA, when a short-circuit fault occurs in the circuit, it can reliably cut off the circuit when the short-circuit current reaches 1kA, and protect the electrical equipment and lines from the damage of short-circuit current.

Impact withstand voltage: 4kV, with high impact withstand voltage capacity, can appear in the power grid transient overvoltage, such as lightning impact, etc., can still work normally, to protect the stability of equipment and systems.

Performance characteristics

Leakage protection function: by detecting the residual current in the circuit to determine whether a leakage fault occurs. Under normal circumstances, the three-phase current vector sum in the circuit is zero, zero-sequence current transformer has no induced electromotive force. When leakage occurs, such as human electric shock or equipment insulation damage caused by current leakage, the three-phase current vector sum is no longer zero, the zero sequence current transformer generates inductive electromotive force, triggering the action of the release device, quickly cut off the circuit, thereby protecting personal safety and preventing electrical fires and other accidents.

A variety of leakage current type detection: A type leakage circuit breaker, not only can detect AC residual current, but also can detect pulsating DC residual current, containing electronic equipment such as DC component leakage faults can also be effectively detected and protected, expanding the scope of protection, improve the reliability of protection.

High breaking capacity: short-circuit breaking capacity of 1kA, in the event of a short-circuit fault, can quickly cut off the short-circuit current, limiting the extent of damage to the fault current on the lines and equipment, to ensure the stability and safety of the electrical system, reduce the short-circuit faults triggered by the outage time and the cost of equipment maintenance.

Good environmental adaptability: the working temperature range is - 25℃ to 55℃, it can work normally in a wide temperature range, and adapt to different environmental conditions of the electrical installation places, such as indoor and outdoor distribution boxes, distribution cabinets and so on. In addition, its protection class IP2X can effectively prevent the intrusion of foreign objects, and adapt to certain dust and foreign object protection requirements.

Compact Design and Convenient Installation: DIN rail mounting is adopted, which is convenient and quick to install, saves installation space and time, and facilitates the layout and maintenance in the distribution cabinet or distribution box. Its small external dimensions and compact structure make it suitable for installation in electrical control boxes with limited space.

Selective protection function: It has selective protection function, which can be set according to the actual application requirements. In the multi-level earth leakage protection system, through the reasonable setting of the action time and action current of all levels of earth leakage circuit breakers, to achieve selective cooperation between the upper and lower levels, to ensure that in the event of an earth leakage fault, only the leakage circuit breaker closest to the point of the fault operates, reducing the scope of the blackout, and improving the reliability and continuity of the power supply.

Application field

Industrial field: Widely used in all kinds of industrial plants and workshops for the protection of electrical equipment, such as electric motors on production lines, processing equipment, lighting systems and so on. It can effectively prevent the safety accidents caused by equipment leakage, short-circuit and other faults, ensure the normal progress of industrial production, and improve the service life and operational efficiency of production equipment.

Commercial buildings: In shopping malls, office buildings, hotels and other commercial buildings, it is used to protect lighting circuits, socket circuits, air-conditioning systems, lifts and other electrical equipment. Provide a safe environment for personnel to use electricity, and at the same time to avoid electrical fires caused by leakage faults, to protect the electrical facilities of commercial buildings and property safety.

Residential buildings: It is one of the important protection appliances in the residential distribution box, providing leakage protection for household electrical equipment, such as sockets, lighting fixtures, household appliances and so on. It can effectively prevent personal electric shock accidents caused by leakage of electrical appliances, and protect the life safety of residents and the reliability of home electricity.

Public facilities: including schools, hospitals, gymnasiums, libraries and other public facilities in the electrical system, for the protection of various types of electrical equipment and lighting facilities, to ensure the safety of electricity in public places, to provide people with a safe and comfortable environment for public activities.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming
  • ADLINK NuPRO-775 Industrial Motherboard Installation and BIOS Configuration Detailed Explanation
  • ETEL Accuret MODULAR 300/400/600 Controller Selection Guide
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting