Product series:
Symphony Harmony/INFI 90:
Conductor VMS
Modular Power System l
Modular Power System ll
Modular Power System lll
Modular Power System lV
Bridge Controller
Multi-function Processor
Harmony Area Controller
Harmony Rack l/O
Harmony Block l/o
Harmony with s800 I/O
Harmony Control Network
After-sales service:
1. The key customer base is an important part of the survival and further development of the enterprise. Through the return visit and communication of the key customers, the customer demand is gradually improved and the customer satisfaction is improved
2 Due to human factors (self-disassembly, fall or external impact, etc.), irresistible factors (such as natural disasters, etc.) improper storage (rats, liquid infiltration, etc.) caused by computer failure, not free warranty service.
3 Damage to electronic components such as chips and capacitors due to voltage, or failure or damage caused by use in working environments other than those specified in the product manual (such as excessively low ambient temperature; The environment is too wet or dry; Voltage or current instability, etc.), not free warranty service.
Product model:
ABB
58921718
protection card
ABB
61320954
Gray Encoder Board
ABB
61353372
protection card
ABB
63911500
Connection board
ABB
64250175
switch fuse
ABB
64581805
switch fuse
ABB
64787039
switch fuse
Product Description:
3.1.2 Adjustment parameters
Pos: 7.8 /Technische Daten / Datenblatt/Aktorik/Stellungsregler/TZIDC / TZIDC-200/Betrieb/Justageparameter @ 10mod_1176214397515_3101.doc @ 77364
The TZIDC positioner has a special function for automatic adjustment
of the parameters.
Additionally, the control parameters can be set automatically (in
adaptive control mode) or manually to optimally adapt them to the
process requirements.
Tolerance band
When reaching the tolerance band the position is considered as
corrected. From this point on, the position is further slowly readjusted
until the dead band is reached. The factory setting for this
parameter is 0.3 %.
Dead band (sensitivity)
When reaching the dead band, the position is held. The factory
setting for this parameter is 0,1 %.
Actuator spring action
Selection of the sensor shaft rotating sense (looking into the open
case), if the valve is moved to the safe position by the actuator spring
(actuator is depressurized via Y1/OUT1).
For double-acting actuators the actuator spring action corresponds to
pressurizing the pneumatic output (OUT2).
Display 0 ... 100 %
Adjusting the display (0 ... 100 %) according to the direction of action
for opening or closing the valve.
Pos: 7.9 /Überschriften/1.1.1/2-spaltig/Betriebsüberwachungsparameter @ 10mod_1176214071453_3101.doc @ 77187
email:1583694102@qq.com