The GE 760-P5-G5-S5-HI-A20-R-E motor management relay is a high-performance motor protection and control device launched by General Electric (GE), designed specifically for the safe operation, status monitoring, and fault diagnosis of various asynchronous motors in industrial scenarios. This relay integrates comprehensive protection functions, precise measurement capabilities, and flexible communication interfaces, which can effectively avoid damage to motors caused by overload, phase loss, short circuit and other faults, extend equipment service life, and improve the reliability and operation efficiency of production systems. It is widely used in motor control circuits in metallurgy, chemical industry, power, water treatment, manufacturing and other fields.
GE 760-P5-G5-S5-HI-A20-R-E Motor Management Relay
Product Overview
The GE 760-P5-G5-S5-HI-A20-R-E motor management relay is a high-performance motor protection and control device launched by General Electric (GE), designed specifically for the safe operation, status monitoring, and fault diagnosis of various asynchronous motors in industrial scenarios. This relay integrates comprehensive protection functions, precise measurement capabilities, and flexible communication interfaces, which can effectively avoid damage to motors caused by overload, phase loss, short circuit and other faults, extend equipment service life, and improve the reliability and operation efficiency of production systems. It is widely used in motor control circuits in metallurgy, chemical industry, power, water treatment, manufacturing and other fields.
Core functions and protective features
As the "safety guard" for motor operation, the core function of this relay revolves around the "protection monitoring control" trinity, with specific characteristics as follows:
1. Comprehensive fault protection
-Overload protection: Adopting inverse time protection curve, the protection threshold can be accurately set according to the rated current of the motor. When the motor is overloaded for a long time and the current exceeds the threshold, the relay will delay the action and cut off the circuit to avoid winding overheating and burning out; Simultaneously supporting overload warning function, sending signals in advance to alert operation and maintenance personnel.
-Phase loss/imbalance protection: Real time monitoring of the three-phase current of the motor. When one or more phases are disconnected or the three-phase current imbalance exceeds the set value (such as 10% -20%), the protection action is quickly triggered to prevent the motor from generating excessive torque and current damage due to single-phase operation.
-Short circuit protection: It has the functions of instantaneous short circuit and short delay short circuit protection. It intelligently identifies the impact current and fault short circuit current at the moment of motor start-up, quickly cuts off the power supply in case of short circuit, and reduces the risk of fault expansion.
-Other specialized protections: including stall protection (triggered by sudden increase in current when the motor is stuck), undervoltage/overvoltage protection (activated when the grid voltage fluctuates abnormally), grounding fault protection (detecting ground leakage current, preventing electric shock and equipment failure), etc., covering the risks of motor operation in all scenarios.
2. Precise operation monitoring
The relay is equipped with high-precision current and voltage sensors, which can real-time collect motor operating parameters, including three-phase current, line voltage, power factor, active power, reactive power, cumulative operating time, etc., and present them intuitively through panel indicator lights or external display modules. Simultaneously supporting fault recording function, it can store the type, occurrence time, and parameter data of the most recent multiple faults, providing strong basis for fault troubleshooting.
3. Flexible control and communication
The control logic supports multiple motor starting methods such as direct start, star delta start, and self coupling pressure reduction start, and can achieve motor start stop control through external contacts or remote signals. Equipped with standard communication interfaces (such as RS485, supporting industrial protocols such as Modbus and Profibus), it can be connected to factory automation systems (SCADA, DCS) to achieve remote monitoring of motor operation status, remote parameter setting, and remote fault alarm, assisting in digital operation and maintenance of factories.
Key technical parameters
parameter category
Specifications
Instructions
rated current
Depending on the configuration, it supports 0.1A-1000A
Small currents can be directly connected, while large currents require the use of current transformers
rated voltage
AC 220V/380V/400V, DC 24V optional
Adapt to different power grid systems
Protecting Action Accuracy
Current measurement accuracy ± 1%, voltage measurement accuracy ± 1.5%
Ensure the accuracy of protection and monitoring
Action response time
Short circuit protection ≤ 10ms, other protections ≤ 100ms
Quick response, reducing fault losses
environmental conditions
Working temperature: -20 ℃~+60 ℃, relative humidity: ≤ 95% (no condensation)
Adapt to the complex environment of industrial sites
Output contact
2 sets of normally open+2 sets of normally closed, contact capacity AC 250V/5A
Used for controlling contactors, alarm signals, etc
communication interface
RS485, Supports Modbus RTU protocol
Compatible with mainstream industrial automation systems
Key points for installation and debugging
1. Installation specifications
The relay should be installed in a well ventilated, dust-free, non corrosive gas, and away from strong magnetic fields control cabinet, using 35mm standard guide rails for installation, and the installation position should be easy to observe and operate. When wiring, it is necessary to strictly distinguish between current circuits, voltage circuits, and control circuits to ensure that the wiring is firm and well insulated. Open circuits are strictly prohibited on the secondary side of current transformers, and short circuits are strictly prohibited on voltage circuits.
2. Debugging core steps
1. Parameter configuration: Based on the rated parameters of the motor (such as rated current, rated voltage, starting mode), set protection thresholds, action delays, communication addresses, and other parameters through panel buttons or software tools.
2. Function testing: Simulate fault scenarios such as overload, phase loss, short circuit, etc., and check whether the relay can accurately trigger the protection action and whether the alarm signal is output normally.
3. Communication testing: Connect to the automation system to test the remote upload of operating parameters and the execution of remote control instructions, ensuring stable communication.
Product advantages and application scenarios
1. Core advantages
-High reliability: using industrial grade components and anti-interference design, suitable for harsh industrial environments, with a long mean time between failures (MTBF).
-Comprehensive functionality: Integrating multiple protection and monitoring functions without the need for additional equipment configuration, reducing system integration costs.
-Strong usability: intuitive operation interface and flexible parameter configuration method, simplifying installation and debugging process, reducing operation and maintenance difficulty.
2. Typical application scenarios
-Manufacturing industry: protection and control of production line conveyor motors, fans, and water pumps.
-Metallurgical industry: safety monitoring of high-power motors such as steel rolling equipment and blast furnace fans.
-Chemical industry: Explosion proof applications for reaction kettle stirring motors and conveying pump motors (requiring explosion-proof enclosures).
-Water treatment: Continuous operation protection of sewage lift pumps and water supply pump motors.





Email:wang@kongjiangauto.com