  • GE 760-P1-G1-S1-LO-A20-R 760 Series Management Relay
    ❤ Add to collection
  • GE 760-P1-G1-S1-LO-A20-R 760 Series Management Relay

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE 760-P1-G1-S1-LO-A20-R is a high-performance product in the 760 series management relay launched by GE Electric, designed specifically for industrial automation control scenarios. It has precise monitoring, protection, and control functions, which can effectively ensure the safe and stable operation of electrical equipment. It is widely used in distribution systems and motor control circuits in multiple fields such as power, manufacturing, petrochemicals, and construction.

    This relay is developed based on GE's mature power control technology, integrating intelligent monitoring and modular design concepts. It can not only achieve real-time collection and analysis of electrical parameters, but also execute corresponding protection actions according to preset logic, reducing losses caused by equipment failures and improving the reliability and operation efficiency of the entire electrical system.


    • ¥10784.00
      ¥12745.00
      ¥10784.00
      ¥10784.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.150KG
    • Quantity:
    • (Inventory: 99999)
Description

GE 760-P1-G1-S1-LO-A20-R is a high-performance product in the 760 series management relay launched by GE Electric, designed specifically for industrial automation control scenarios. It has precise monitoring, protection, and control functions, which can effectively ensure the safe and stable operation of electrical equipment. It is widely used in distribution systems and motor control circuits in multiple fields such as power, manufacturing, petrochemicals, and construction.

This relay is developed based on GE's mature power control technology, integrating intelligent monitoring and modular design concepts. It can not only achieve real-time collection and analysis of electrical parameters, but also execute corresponding protection actions according to preset logic, reducing losses caused by equipment failures and improving the reliability and operation efficiency of the entire electrical system.





GE 760-P1-G1-S1-LO-A20-R 760 Series Management Relay

Product Overview

GE 760-P1-G1-S1-LO-A20-R is a high-performance product in the 760 series management relay launched by GE Electric, designed specifically for industrial automation control scenarios. It has precise monitoring, protection, and control functions, which can effectively ensure the safe and stable operation of electrical equipment. It is widely used in distribution systems and motor control circuits in multiple fields such as power, manufacturing, petrochemicals, and construction.

This relay is developed based on GE's mature power control technology, integrating intelligent monitoring and modular design concepts. It can not only achieve real-time collection and analysis of electrical parameters, but also execute corresponding protection actions according to preset logic, reducing losses caused by equipment failures and improving the reliability and operation efficiency of the entire electrical system.


Core Features

2.1 Multi dimensional protection function

GE 760-P1-G1-S1-LO-A20-R has a comprehensive protection mechanism that can accurately monitor and respond quickly to various abnormal situations during the operation of electrical equipment. The core protection functions include:

-Overload protection: Through the built-in current detection module, the circuit current is monitored in real time. When the current exceeds the preset overload threshold, the relay will trigger the protection action after a set delay, cut off the circuit or issue an alarm signal, avoiding insulation damage or burnout of the equipment caused by long-term overload.

-Underload protection (LO identification corresponding function): For some equipment that requires stable load operation, this relay can monitor whether the circuit load is below the normal working range. When an underload situation occurs (such as pump equipment idling, conveyor belt slipping, etc.), it will promptly issue a warning or perform shutdown protection to prevent equipment depletion or damage.

-Overvoltage/undervoltage protection: Real time collection of circuit voltage signals. When the voltage exceeds or falls below the preset safe range, the protection logic is quickly activated to avoid voltage fluctuations from impacting sensitive equipment and ensure stable electrical performance of the equipment.

-Short circuit protection: It has the ability to quickly identify short circuits. When a short circuit fault occurs in the circuit, the protection action can be triggered in a very short time, minimizing the damage of short circuit current to equipment and lines.

2.2 Intelligent Monitoring and Control

This relay is equipped with high-precision sensing and detection chips, which can achieve real-time acquisition and accurate measurement of key electrical parameters such as circuit current, voltage, power, and power factor. The measurement data has small errors, providing reliable basis for equipment operation status evaluation.

At the same time, the relay supports flexible parameter configuration functions, and users can customize protection thresholds, delay times, and other parameters according to the needs of actual application scenarios through dedicated interfaces or supporting software to meet the control requirements of different devices. In addition, some models also have data storage and upload functions, which can record key data and fault information during equipment operation, making it easy for operation and maintenance personnel to trace faults and optimize the system.

2.3 High reliability and stability

The GE 760 series relays strictly follow the quality standards of industrial grade products in the design and production process, using high-quality electronic components and housing materials. They have good anti-interference ability, temperature resistance, and humidity resistance, and can adapt to complex environmental conditions in industrial sites (such as high temperature, high humidity, dust, electromagnetic interference, etc.), ensuring that the relays can still operate stably in harsh environments.

The mechanical and electrical lifespan of relays is long, with rapid and reliable action response, reducing the risk of equipment shutdown caused by relay failures and lowering maintenance costs.

2.4 Convenient Installation and Maintenance

This relay adopts a modular structure design, with a compact size and flexible installation method. It can be adapted to standard rail installation or panel installation, making it easy to integrate into existing electrical control cabinets and saving installation space.

In terms of maintenance, relays have clear status indication functions (such as power indicator lights, action indicator lights, fault indicator lights, etc.), and operation and maintenance personnel can quickly determine the working status and fault type of the relay through the indicator lights, shortening the troubleshooting time. At the same time, the wiring terminal design of the relay is standardized, with simple and convenient wiring, reducing the workload of installation and maintenance.


Key technical parameters

power supply voltage

AC 220V/DC 24V (optional)

Depending on the model, it supports AC or DC power input, with a voltage fluctuation range of ± 10%

rated current

According to specific configurations, common specifications include 10A, 20A, 50A, 100A, etc

Can match electrical circuits of different capacities

protection type

Overload, underload, overvoltage, undervoltage, short circuit, etc

Multi dimensional guarantee of equipment security

action delay

Adjustable from 0.1s to 30s

Flexible settings based on protection type and parameter configuration

measurement accuracy

Accuracy of current and voltage measurement ± 1%

Provide accurate electrical parameter data

Working environment temperature

-20℃ - +60℃

Adapt to the wide temperature environment of industrial sites

Protection level

IP20

Suitable for installation inside indoor control cabinets

output method

Relay contact output (normally open/normally closed optional)

Capacity AC 250V/10A, DC 30V/10A


Application scenarios

The GE 760-P1-G1-S1-LO-A20-R management relay, with its comprehensive functionality and high reliability, is widely used in the following scenarios:

1. Motor control: Used for the protection and control of various industrial motors such as fans, water pumps, compressors, conveyors, etc., to prevent motor damage due to overload, underload, abnormal voltage and other faults, and ensure stable operation of the motor.

2. Distribution system: applied in low-voltage distribution circuits to protect the lines and distribution equipment, avoid distribution accidents caused by faults such as short circuits and overloads, and ensure the safety and reliability of the distribution system.

3. Petrochemical industry: Provide precise protection and control in various electrical circuits such as pumps, valves, heating equipment, etc. in the petrochemical production process, adapting to the complex environment of chemical sites.

4. Building electrical: Used for electrical control circuits in building air conditioning systems, water supply and drainage systems, fire-fighting equipment, etc., to ensure the safe operation of building electrical equipment and improve the reliability of building electrical systems.

5. Manufacturing industry: Real time monitoring and protection of various automation equipment electrical control circuits in production lines, reducing production line downtime and improving production efficiency.


Precautions for use

-Before installation, it is necessary to confirm that the model and specifications of the relay are consistent with the actual application requirements, and check whether the parameters such as power supply voltage and rated current match the circuit requirements.

-During the installation process, it is necessary to strictly follow the wiring diagram to ensure that the wiring is firm and correct, avoid misconnections, virtual connections, etc., and prevent short circuits or equipment damage.

-Relays should be installed in a well ventilated, dry, dust-free, and non corrosive gas environment, avoiding direct sunlight and severe vibration, to ensure that their working environment meets the technical parameter requirements.

-When configuring parameters, it is necessary to set the protection threshold and delay time reasonably according to the rated parameters and operating requirements of the equipment, in order to avoid protection failure or misoperation caused by improper parameter settings.

-Regularly maintain and inspect the relay, clean the surface dust, check whether the wiring terminals are loose, whether the indicator lights are normal, and ensure that the relay is in good working condition.

-When troubleshooting, the power supply of the relay should be cut off first, and then relevant operations should be carried out to avoid electric shock accidents. If it is necessary to replace the relay, products of the same model and specifications should be selected to ensure consistent performance.

image.png

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector
  • Microchip PIC16F182X Low Power Design
  • FANUC α iS servo HRV calibration practice
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide