    ABB 560CMR02 Communication unit

    • ¥34000.00
      ¥34670.00
      ¥34000.00
      ¥34000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.400KG
    • Quantity:
    • (Inventory: 33)
Description

ABB 560CMR02 Communication unit


ABB 560CMR02 Communication unit

Communication module for RTU560 with 32 bit CPU 

• 2x serial communication interface (RS-232 or RS-485) for remote communication 

• 2x Ethernet interface (10/100BaseT) 

• 1x USB port 

• 1x serial peripheral bus 

• Battery buffered real time clock

The essential tasks are: 

• Managing and controlling of the I/O modules via the interface to the serial I/O bus. 

• Reading Process events from the input modules. 

• Send commands to the output modules. 

• Communicating with control systems and local HMI systems via the serial interfaces (RS232) and the Ethernet 10/100BaseT interfaces. 

• Communication with Sub-RTU’s, IED’s or multimeter devices via the interfaces (RS485) and the Ethernet interfaces. 

• Managing the time base for the RTU560 product line station and synchronizing the I/O modules. 

• Handling the dialog between RTU560 product line and Web-Browser via the LAN interfaces.

Product Overview

ABB 560CMR02 communication unit is an important part of RTU560 product series, which integrates a powerful 32-bit CPU and a variety of communication interfaces to provide efficient and reliable data transmission and communication solutions for industrial automation. The communication unit is suitable for a variety of complex industrial automation environments and can meet the communication needs of different devices and systems.

Communication interfaces and configurations

Serial communication interfaces: ABB 560CMR02 is equipped with six serial communication interfaces (RS-232 or RS-485), which support remote communication and data transmission. Users can choose the appropriate interface type and configuration to connect and communicate with different devices according to their actual needs.

Ethernet interfaces: The communication unit also provides 2 Ethernet interfaces (10/100BaseT), which support Fast Ethernet connection. These interfaces can be used to communicate with control systems, local HMI systems and other network devices, ensuring real-time data transmission and stable system operation.

USB port: In addition, the ABB 560CMR02 is equipped with a USB 2.0 device interface, which is primarily used for diagnostic and maintenance purposes. By connecting debugging tools or storage devices, users can easily configure, monitor and troubleshoot the communication unit.

Functional features

Interface management and control: The ABB 560CMR02 communication unit manages and controls the I/O modules through the serial I/O bus interface to ensure accurate data transfer and normal device operation. It can read process events from the input module and send commands to the output module, realising real-time data processing and remote control of equipment.

Time base and synchronisation: This communication unit is responsible for managing the time base of RTU560 product line station and synchronising I/O modules to ensure the time consistency and data synchronisation of the whole system. This is crucial for the stable operation and data accuracy of industrial automation systems.

Communication Protocol Handling: The ABB 560CMR02 is capable of handling communication protocols based on Ethernet and UART characters, and supports a wide range of communication standards and protocols, such as Modbus, DNP3, and so on. This enables it to communicate and interoperate with different brands and types of equipment.

Network Security: The communication unit is available in two versions, the R0001 version with standard network security features and the R0002 version with a security chip with higher level network security features. This ensures the security and integrity of data transmission and prevents unauthorised access and tampering.

System Configuration and Storage: System-related configuration files are stored in a non-volatile flash memory card (removable SD card) to ensure that the system configuration is valid after a power-on reset (PoR). This design allows users to easily save and restore system configurations, reducing maintenance costs and time.

Applications and Benefits

Industrial automation and control: ABB 560CMR02 communication unit is widely used in the field of industrial automation and control, which can connect a variety of sensors, actuators, controllers and other equipment to achieve reliable data transmission and interconnection of equipment. It supports the construction and expansion of large-scale industrial automation systems and improves the overall performance and stability of the system.

High performance and stability: The communication unit adopts advanced hardware and software design, which has high performance and stability. It can handle a large amount of data and commands, ensuring real-time data transmission and fast system response. At the same time, it also has good anti-interference ability and fault tolerance, and can operate stably in harsh industrial environments.

Flexibility and expandability: ABB 560CMR02 provides a variety of communication interfaces and configuration options, which can be flexibly configured and expanded according to different application scenarios and needs. Users can choose the appropriate type and number of interfaces, as well as configure the corresponding communication parameters and protocols according to actual needs. This flexibility allows the communication unit to adapt to a variety of complex industrial automation environments and meet the needs of future expansion.

Summary

The ABB 560CMR02 Communication Unit is a high performance communication module with comprehensive features and excellent performance, suitable for a variety of application scenarios such as industrial automation and control systems. It provides a wealth of communication interfaces and configuration options with the advantages of high performance, stability and flexibility. At the same time, the communication unit also supports network security functions and system configuration storage functions to ensure the safety of data transmission and the effectiveness of system configuration. For more information, we recommend visiting the official ABB website or contacting their official customer service for enquiry.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice