ABB RED521 1MRK002003-BA Universal differential protection terminal
ABB RED521 1MRK002003-BA Universal differential protection terminal
Product Overview
ABB RED521 1MRK002003-BA is a high-performance differential protection terminal produced by ABB, which adopts advanced technology and design with high reliability and stability. The terminal is able to monitor the current, voltage and other parameters of the power system in real time and quickly cut off the circuit when abnormal conditions are detected, so as to protect the safe and stable operation of the power equipment and system.
Main Functions
Differential protection function: RED521 1MRK002003-BA is equipped with powerful differential protection function, which can accurately detect abnormal conditions such as short-circuit and ground faults in the power system and quickly cut off the faulty circuits, thus preventing damage to the equipment and injury to the personnel.
Real-time clock and external synchronisation: The terminal has a built-in real-time clock and supports synchronisation with external time sources to ensure the accuracy and consistency of time recording.
Extensive self-supervision: The RED521 1MRK002003-BA has extensive self-supervision features that enable it to monitor its own working status and performance in real time, and to detect and deal with potential problems in a timely manner.
Built-in Local HMI with LED Indication: The terminal is equipped with an intuitive local HMI and LED indicators for easy operation and status monitoring.
High-precision data acquisition: RED521 1MRK002003-BA has high-precision data acquisition capability, which ensures that the collected data is accurate and reliable, providing powerful support for power system monitoring and control.
Technical Features
Pre-configured and ready for use: RED521 1MRK002003-BA is pre-configured and ready for use before leaving the factory, so users can use it directly without complicated settings and debugging.
Easily adaptable to different substation configurations: the terminal is highly flexible and adaptable, and can be easily adapted to substations of different sizes and power system configurations.
No need to insert CT, no need to switch CT secondary circuit: RED521 1MRK002003-BA has a low CT requirement, requiring only 2 ms saturation to operate correctly, no need to insert CT or switch CT secondary circuit, reducing installation and maintenance costs.
Supports multiple communication interfaces: The terminal supports multiple communication interfaces, such as Ethernet, serial port, etc., which facilitates data exchange and integration with other systems and devices.
Application Fields
ABB RED521 1MRK002003-BA universal differential protection terminal is widely used in the following fields:
Power system protection: It is used for differential protection of power system to ensure the safe and stable operation of power system.
Industrial automation: In industrial automation system, it is used to monitor and control various power equipments to improve production efficiency and quality.
Energy management: in the energy management system, it is used to monitor and control the current, voltage and other parameters of the power grid to optimise the efficiency of energy use.
Maintenance and care
In order to ensure the stable operation of the ABB RED521 1MRK002003-BA general-purpose differential protection terminal, the following maintenance and repair work is required:
Regular inspection: Inspect the terminal regularly to ensure that it is in normal working condition and that potential problems are found and dealt with in time.
Cleaning and maintenance: Keep the terminal clean and dry to prevent dust and moisture from entering the interior and causing damage.
Firmware update: Update the terminal's firmware and software in time to get the latest functions and security patches.
Professional training: Provide professional training to operation and maintenance personnel to improve their ability to use and maintain the terminal.
Installation and Maintenance
Environmental Conditions:
Ensure that the module is installed within the recommended temperature and humidity ranges and avoid direct exposure to water, oil, dust or electromagnetic interference.
Power Requirements:
Use a stable power supply to avoid damage to the module from voltage fluctuations.
Signal Cable Connection:
Connect the signal lines correctly to ensure the accuracy and stability of signal transmission.
Software Configuration:
Correctly configure the software parameters of the module according to the system requirements to ensure compatibility with other parts of the control system.
Maintenance and Inspection:
Perform regular maintenance and inspection of the module, including cleaning and checking the contact status of the connectors.
Precautions
Operator Training:
Operators should receive proper operation and maintenance training to avoid malfunctions or safety accidents caused by incorrect operation.
Technical Documentation and Safety Guidelines:
The technical documentation and safety guidelines provided by the manufacturer should be read and understood in detail before installation and use.
Compliance with safety procedures:
Observe all relevant safety procedures to ensure personal safety, especially when handling high-pressure or high-speed rotating equipment.
email:1583694102@qq.com