ADVANTEST R3765CG Network Analyzer
ADVANTEST R3765CG Network Analyzer
INTRODUCTION
Vector Network Analyzers in the R3765CG/3767CG propose a new RF circuit analysis procedure. Range of measurement frequency is 300 kHz to 3.8 GHz (R3765CG) or 300 kHz to 8 GHz (R3767CG). A unique high-speed signal processing technology adopted to the R3765CG/3767CG has realized enhanced measuring speed. The R3765CG/3767CG are a model with a built-in S parameter test set to deal with forward/reverse directions measurements. Further, lined up, as optional, are a model with a built-in 3- port test set and a model with a built-in 4-port test set. Additional installation of input channels to the receptor assembly of these multi-port models will make them capable of performing simultaneous measurement of 2 different paths to be tested. Adopting this method will result in substantial improvement to measuring efficiency of multi-port devices. Adopted is 8.4-inch TFT color LC monitor that is capable of displaying 4-sectioned screens at a time, thus making possible of choosing independently one measuring path in each section, realizing simultaneous display of a maximum of 4 paths and 8 parameters that results in an instantaneous analysis of variety of items subject to measurements. Sweep time is as short as 150 µs/point, thus realizing a further high speed.
BENEFITS
High-speed, High-accuracy Measurements
•150 µs/point (with 2-port Full Calibration)
•3-port or 4-port full calibration
•High-speed data transfer late
•Extended resolutions (10 Hz to 20 kHz) set by IF RBW
Wide View Multi Screen
•Uses 8.4-inch TFT color LC monitor
•Enhanced visibility to waveforms
•Varieties of displaying layouts
Extended Analysis Functions
•New system, built-in 3-port test set
•4-channel independent paths displaying function
•CDMA IF filter analysis
•Time domain analysis
Superior Operability
•Verification
•Limit-line function
•Automatic calibration
PC Friendly
•Built-in BASIC Controller
•Built-in programming editor
•Varieties of interfaces for external devices
Software Fixture
•Impedance conversion function
•Matching networking function
•Port conversion function
•Balance parameter measurement function
•Data storage function
4-port Full Calibration
By 4-port device testing, it is not possible to remove thoroughly error factors from a system tested by a 2-port full calibration. For high accuracy testing of 4-port devices, error factors other than those in the paths being tested must be taken into consideration. Models having built-in 4-port test set are also equipped with 4- port full calibration function that solves such a problem. When measuring a 4-port device, full 4-port calibration thoroughly corrects errors from measurement system of 4-port networks. Accordingly, when measurements on the path between port 1 and 2 are performed, measurements on the paths between all ports are performed. In other words, the measurement on all possible six paths between 4 ports (1-2, 1-3, 1-4, 2-3, 2-4, and 3-4) are performed, thus all of sixteen S parameters have been obtained.
email:1583694102@qq.com
wang@kongjiangauto.com