    BENTLY 330704-000-050-10-02-05 Proximity Sensor

    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

BENTLY 330704-000-050-10-02-05 Proximity Sensor


BENTLY 330704-000-050-10-02-05 Proximity Sensor

Overview

The BENTLY 330704-000-050-10-02-05 is a proximity sensor manufactured by BENTLY Nevada and is part of the 3300 XL 11 mm Proximity Probe Series.

Specifications

Physical Characteristics: Probe has an overall length of 50mm, an overall length of 1.0 metre, a typical diameter of 41mm, a typical height of 102mm and a weight of approximately 480g.

Probe Material: The probe tip is made of polyphenylene sulfide (PPS), the probe housing is made of AISI 304 stainless steel, and the sealing material is fluorine rubber (Viton®) O-ring.

Electrical Characteristics: Sensitivity 20 mv/mm/s (500 mv/in/s) ±5%, frequency response from low operating frequency to 1kHz, 50g peak acceleration, lateral sensitivity ±10%.

Environmental constraints: Operating and storage temperature range of -29°C to +21°C, 95% non-condensing relative humidity, dust and moisture proof.

Product Features

Highly accurate measurement: It can accurately detect the proximity of the target object and measure small displacement changes, providing accurate data support for the condition monitoring of industrial equipment and helping to detect potential faults in a timely manner.

High Reliability: Adopting high quality materials and advanced manufacturing process to ensure stable and reliable operation even in harsh industrial environments, reducing equipment downtime due to sensor failure.

Easy to install and use: Equipped with standard cables and miniature coaxial Click Loc™ connectors, it is easy to connect and install with other equipments, which reduces the installation cost and difficulty.

Compatibility: Compatible with other BENTLY Nevada monitoring equipment and systems, such as the 3500 series monitors, for an integrated, all-in-one monitoring system.

Application Areas

Rotating machinery monitoring: commonly used to monitor shaft vibration and shaft displacement of turbines, generators, compressors and other rotating machinery, through real-time monitoring of shaft movement status, timely detection of imbalance, misalignment, bearing wear and other issues to ensure the safe and stable operation of rotating machinery.

Industrial automated production line: In the automated production line, it can be used to detect the position of materials, the presence or absence of objects on the conveyor belt, etc., to provide accurate position information for the automated control system, and to achieve precise control and automated operation of the production process.

Automotive manufacturing: in the production process of automotive engines, transmissions and other components, can be used to monitor the assembly position and clearance of parts to ensure product quality and performance consistency.

Aerospace: It plays an important role in the monitoring of aircraft engines, landing gear and other key components to ensure the reliability and safety of aerospace equipment.

Product Features

High accuracy: the sensor has a high-precision measurement capability and can accurately reflect the displacement of the shaft or target surface.

High sensitivity: In a specific frequency and displacement range, the sensor shows high sensitivity and can respond quickly to changes in the measurement object.

Non-contact measurement: Adopting the eddy current convergence measurement principle to realise non-contact measurement, avoiding the wear and error that may be brought by traditional contact measurement.

Reliability: The internal structure of the sensor is optimised for excellent stability and durability, enabling it to work for a long time in harsh industrial environments.

Technical Parameters

Model: 330704-000-050-10-02-05

Sensitivity: at a specific frequency (e.g. 100Hz), with a specific sensitivity value (e.g. 20mV/mm/s or 500mV/in/s), and allows a certain error range (±5%).

Frequency Response: The sensor maintains stable performance from small operating frequencies to higher frequency ranges (e.g. 1kHz or 10kHz).

Lead length: Sensors have long leads for easy connection to preamplifiers or other monitoring equipment.

Use and storage temperature: the sensor has a wide use and storage temperature range, can adapt to different working environments.

Principle of operation

BENTLY 330704-000-050-10-02-05 sensor adopts eddy current convergence measurement principle. When the coil on the top of the probe is coupled with a high-frequency current and brought into close proximity with a conductive surface, eddy currents are generated on the surface of the conductive object due to the action of the coil's magnetic lines of force, which reduces the inductance of the coil. This change in coil characteristics is converted to a DC voltage signal output, which enables the measurement of displacement or vibration.

Applications

The sensor is widely used in various industrial fields, especially where vibration and displacement of large rotating machinery (such as steam turbines, hydraulic turbines, fans, compressors, etc.) need to be monitored. It can provide important data support for equipment condition monitoring, fault early warning and maintenance, which helps to reduce equipment failure and improve production efficiency.

Installation and Maintenance

Installation: The sensor should be installed in the machine can accurately reflect the displacement or vibration of the position. In the installation process, should ensure that the sensor's electrical connections are correct and reliable, and avoid exposure to extreme temperatures or humidity.

Maintenance: Sensors should be maintained and calibrated regularly to ensure their measurement accuracy and reliability. During maintenance, care should be taken to check that the leads, connectors and internal structure of the sensor are in good condition and should be replaced or repaired if damaged.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide