Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • BENTLY 350053 Electronic Overspeed Detection System
    ❤ Add to collection
  • BENTLY 350053 Electronic Overspeed Detection System

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    BENTLY 350053 Electronic Overspeed Detection System

    • ¥23650.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description

BENTLY 350053 Electronic Overspeed Detection System


BENTLY 350053 Electronic Overspeed Detection System

DESCRIPTION

Bently Nevada’s Electronic Overspeed Detection System for the 3500 Series Machinery Detection System provides a highly reliable, fast response, redundant tachometer system intended specifically for use as part of an overspeed protection system. It is designed to meet the requirements of American Petroleum Institute Standards 670 and 612 pertaining to overspeed protection.

SPECIFICATIONS

Input voltage:110V-380V

Electric current:1A-30A

Power: 5W-130W

Warranty period:1 year

Stock Quantity:30

Place of origin:United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia 

Main Features

High reliability: The system adopts redundant design, including redundant power supply and redundant tachometer, to ensure that the normal operation of the system can still be maintained in the event of a single component failure.

Fast Response: The system can monitor the rotational speed of machinery and equipment in real time and quickly send out an alarm signal when it exceeds the speed limit, avoiding possible accidents.

Multiple Sensor Support: The system supports multiple types of sensors, including eddy current sensors and magnetic sensors, and is able to receive signals from different sensors for broader compatibility.

Easy to Configure and Maintain: The system provides easy-to-use configuration software and humanised user interface, which is convenient for users to configure, debug and maintain the system.

Technical Specifications

Input Signal: Each overspeed detection module receives a signal from an eddy current sensor or a magnetic sensor, and the input signal ranges from +10.0 V to -24.0 V. Signals outside this range are limited within the module.

Input impedance: 20kΩ.

Power Consumption: Typically 8.0W.

Sensors: Supports Bently Nevada 3300 8mm eddy current sensors, 3300 16mm high temperature eddy current sensors (HTPS), 7200 5mm, 8mm, 11mm, and 14mm eddy current sensors, 3300 RAM eddy current sensors, or magnetic sensors.

Alarm Settings: Setpoints are all set by software configuration, alarm points are adjustable and are typically adjusted from 0 to 100% of full scale.

Output: A variety of output options are provided, including proportional output value, recorder output and relay output, etc., which are convenient for users to choose according to actual needs.

Functions and Applications

Overspeed protection: The system can monitor the rotational speed of mechanical equipment in real time and send out an alarm signal when the rotational speed exceeds the preset threshold, so as to realise the overspeed protection function.

Data Recording and Analysis: The system supports data recording and analysis function, which can record the rotational speed data of mechanical equipment and conduct statistical analysis to help users optimise the operation and maintenance strategy of the equipment.

Integration with other systems: the system supports a variety of communication protocols, and can be seamlessly integrated with other automation equipment to achieve automated control and monitoring of the entire production line.

Installation and Maintenance

Installation: When installing the system, ensure that all components are properly connected and follow the manufacturer's installation guidelines. Particular attention should be paid to the installation location of the redundant power supply and redundant tachometer to ensure system redundancy.

Maintenance: Periodically clean and inspect the system to ensure that its surfaces are free of dirt and damage. At the same time, the system's connecting wires and connectors should be inspected for looseness or damage, and damaged parts should be replaced in a timely manner. In addition, the system needs to be calibrated and tested regularly to ensure its measurement accuracy.

Precautions

Environmental adaptability: When selecting and using the system, consideration should be given to whether its working environment meets the performance requirements of the system, such as temperature, humidity and electromagnetic interference.

Safe operation: When installing, maintaining and calibrating the system, the manufacturer's safe operation procedures should be followed to ensure the safety of the operators.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide