Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB Binary Output Module CBO 10 H&B Contronic
    ❤ Add to collection
  • ABB Binary Output Module CBO 10 H&B Contronic

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Binary Output Module CBO 10 H&B Contronic
    • ¥1856.00
      ¥6002.00
      ¥1856.00
      ¥1856.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
Binary Output Module CBO 10 H&B Contronic

ABB Binary Output Module CBO 10 H&B Contronic

The ABB Binary Output Module CBO 10 H&B Contronic has the following features:

Basic information: model number CBO 10, product number p 72133-4-0788733, origin is Germany, shipping place is Webster, New York, USA, dimensions are about 20.3cm x 5.1cm x 30.5cm, weight is about 0.7kg.

Functional characteristics: As a binary output module, it can convert digital signals into binary output signals, which can be used to control the switching state of external devices such as relays and contactors, and realise the control of all kinds of devices in industrial processes. Its internal isolation circuit can prevent external interference and faults affecting the internal circuit, improve system reliability and stability, and ensure the accuracy and stability of the signal output. Moreover, the module belongs to ABB H&B Contronic and ABB H&B Melody/Contronic S series, which can be easily combined with other modules of the same series, such as input modules, control modules, etc., to build a complete industrial automation control system.

Applications: Widely used in chemical industry, electric power, metallurgy, water treatment and many other industrial automation fields, commonly used in motor start/stop control, valve switch control, signal light control, etc., which can effectively improve the production efficiency, reduce the labour intensity, and enhance the reliability and stability of the entire production system.

OTHER INFORMATION

• The operator panel is designed for stationary installation on a planar surface, where the following conditions are fulfilled: 

– no high explosive risks 

– no strong magnetic fields 

– no direct sunlight 

– no large, sudden temperature changes 

• Install the operator panel according to the accompanying installation instructions. 

• Ground the operator panel according to the accompanying installation instructions. 

• Only qualified personnel may install the operator panel. 

• Separate the high voltage, signal and supply cables. 

• Make sure that the voltage and polarity of the power source is correct before connecting the operator panel to the power outlet. 

• Peripheral equipment must be appropriate for the application and location. 

• In a Zone 2 environment, this equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 or greater than IP 65 in accordance with IEC/EN 600079-0. The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into. 

• In a Zone 22 environment, this equipment shall be installed in an enclosure that provides a degree of protection not less than IP 64 or greater than IP 65 in accordance with IEC/EN 600079-0. The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into.

Service and Maintenance

• Only qualified personnel should carry out repairs. 

• The agreed warranty applies. 

• Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical supply. 

• Clean the display and surrounding front cover with a soft cloth and mild detergent. 

• Replacing the battery incorrectly may result in explosion. Only use batteries recommended by the supplier. During the warranty period, the battery needs to be replaced by an authorized ABB service center

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice