Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE D20 EME210BASE-T Ethernet Module
    ❤ Add to collection
  • GE D20 EME210BASE-T Ethernet Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE D20 EME210BASE-T is an industrial grade Ethernet communication module specially designed by General Electric (GE) for the D20 series distributed control system. As the "communication bridge" of the system, its core function is to achieve high-speed data exchange between the D20 controller and the upper monitoring system, other intelligent devices, and remote terminals. This module adopts the 10/100BASE-T adaptive Ethernet standard, which has the characteristics of stability, reliability, strong anti-interference, and flexible configuration. It is widely used in industrial fields such as power, chemical, and metallurgy, providing solid support for networked monitoring and management of distributed control systems.

    • ¥8046.00
      ¥8257.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.450KG
    • Quantity:
    • (Inventory: 99999)
Description

GE D20 EME210BASE-T is an industrial grade Ethernet communication module specially designed by General Electric (GE) for the D20 series distributed control system. As the "communication bridge" of the system, its core function is to achieve high-speed data exchange between the D20 controller and the upper monitoring system, other intelligent devices, and remote terminals. This module adopts the 10/100BASE-T adaptive Ethernet standard, which has the characteristics of stability, reliability, strong anti-interference, and flexible configuration. It is widely used in industrial fields such as power, chemical, and metallurgy, providing solid support for networked monitoring and management of distributed control systems.


GE D20 EME210BASE-T Ethernet Module

Product Overview

GE D20 EME210BASE-T is an industrial grade Ethernet communication module specially designed by General Electric (GE) for the D20 series distributed control system. As the "communication bridge" of the system, its core function is to achieve high-speed data exchange between the D20 controller and the upper monitoring system, other intelligent devices, and remote terminals. This module adopts the 10/100BASE-T adaptive Ethernet standard, which has the characteristics of stability, reliability, strong anti-interference, and flexible configuration. It is widely used in industrial fields such as power, chemical, and metallurgy, providing solid support for networked monitoring and management of distributed control systems.

As a core component of the D20 system communication architecture, the EME210BASE-T module is not only compatible with GE's proprietary communication protocols, but also supports multiple industrial standard protocols, enabling seamless integration with automation systems from different vendors. Its industrial grade hardware design can adapt to harsh industrial site environments, effectively resist the effects of electromagnetic interference, voltage fluctuations, etc., ensure the real-time and integrity of data transmission, and is a key communication equipment to ensure the efficient collaborative operation of D20 systems.


Core functions and roles

1. High speed Ethernet data transmission

This module supports 10Mbps/100Mbps adaptive Ethernet rates and adopts full duplex communication mode, with a maximum data transmission rate of 100Mbps. It can quickly transmit on-site device operation data (such as temperature, pressure, flow rate, etc.) collected by the D20 controller and control instructions issued by the upper system. Its built-in traffic control mechanism can effectively avoid data congestion and ensure stable communication performance even under high load conditions.

2. Multi protocol compatibility and interconnection

The EME210BASE-T module has strong protocol compatibility capabilities, supporting GE's proprietary Genius protocol and SRTP protocol to ensure seamless communication with various components within the D20 system; On the other hand, it is compatible with industrial standard communication protocols such as Modbus TCP/IP and EtherNet/IP, enabling interconnectivity with third-party PLCs, SCADA systems, HMI human-machine interfaces, and other intelligent devices, breaking down communication barriers between different systems.

3. System communication management and routing

The module has built-in simple routing function, which can realize data forwarding between different network segments. It supports the classification and transmission of device data of D20 controller according to priority, ensuring the priority transmission right of key control signals. At the same time, the module has communication status monitoring function, which can real-time calculate parameters such as data transmission volume, packet loss rate, and communication link status, providing data support for operation and maintenance personnel to grasp the system communication status.

4. Network security and fault protection

In response to industrial network security requirements, the module supports basic security functions such as IP address filtering and port access control, which can restrict illegal devices from accessing the network and prevent data from being illegally stolen or tampered with. In addition, the module has link fault detection and automatic recovery functions. When the Ethernet link is interrupted, it will immediately trigger an alarm signal and attempt to reconnect automatically. At the same time, the fault information will be uploaded to the D20 controller for quick troubleshooting.

5. Flexible configuration and remote management

The module supports two configuration methods: local parameter configuration through D20 system programming software (such as IP address, communication protocol, port settings, etc.); Remote parameter modification, firmware upgrade, and fault diagnosis can be achieved through Ethernet, without the need for on-site operation, greatly improving operation and maintenance efficiency. The configuration parameters can be saved locally to avoid parameter loss caused by module restart.


Key technical parameters

Ethernet standard

10/100BASE-T(IEEE 802.3)

Supports rate adaptation and is compatible with 100Mbps/10G Ethernet

communication mode

Full duplex/half duplex adaptive

In full duplex mode, data conflicts can be avoided and transmission efficiency can be improved

Supported Protocols

Genius、SRTP、Modbus TCP/IP、EtherNet/IP

Compatible with GE exclusive protocols and industrial standard protocols

network interface

2 RJ45 ports (1 primary and 1 backup, supporting link redundancy)

Primary and backup port design improves communication link reliability

IP characteristics

Support static IP and DHCP automatic acquisition

IP configuration requirements for adapting to different network environments

Working Voltage

DC 24V ±15%

Adapt to D20 system standard DC power supply

Working temperature range

-40℃ ~ 70℃

Adapt to high and low temperature industrial site environments

Protection level

IP20 (module body)

Suitable for installation inside control cabinets to prevent solid foreign objects from entering

Electromagnetic Compatibility

Compliant with IEC 61000-4 standard

Capable of strong resistance to electromagnetic interference

Installation method

DIN rail installation/panel installation

Adapt to different control cabinet layout requirements


Applicable scenarios and application areas

The EME210BASE-T Ethernet module, as the core communication component of the D20 system, is highly compatible with the application fields of the D20 distributed control system, mainly including the following industrial scenarios:

1. Power industry: Used for unit control systems in thermal power plants and hydropower stations, realizing data exchange between D20 controllers and power plant SIS and MIS systems, transmitting unit operating parameters, control instructions, and fault information, and supporting centralized monitoring and management of power plants.

2. Petrochemical industry: Applied in distributed control systems for refining equipment and chemical reaction vessels, connecting on-site sensors, actuators, and SCADA systems in the central monitoring room to achieve real-time acquisition and remote control of production process parameters, ensuring stable operation of the production process.

3. Steel and metallurgical industry: Control systems for heating furnaces, continuous casting machines, and other equipment that are compatible with metallurgical production lines. Data exchange between D20 systems and production management systems is achieved through Ethernet modules, providing data support for production scheduling and quality control.

4. In the field of municipal engineering: used for automation control systems in sewage treatment plants and water treatment plants, to achieve remote monitoring of on-site equipment operation status and issuance of control instructions, and to improve the operation and maintenance efficiency of municipal facilities.

5. Other industrial fields, such as cement production and paper industry, use D20 distributed control system scenarios to provide reliable support for networked communication of the system.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution