Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200DCFBG1B DC Feedback Power Supply Board
    ❤ Add to collection
  • GE DS200DCFBG1B DC Feedback Power Supply Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200DCFBG1B DC Feedback Power Supply Board

    • ¥23650.00
      ¥34670.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.400KG
    • Quantity:
    • (Inventory: 33)
Description

GE DS200DCFBG1B DC Feedback Power Supply Board


GE DS200DCFBG1B DC Feedback Power Supply Board

Part Number DS200DCFBG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200DCFBG1B is a DC Power Supply Feedback Board manufactured and designed by General Electric. It used in EX2000, DC2000, CB2000, FC2000, GF2000, ME2000, and AC2000, IGBT drive applications. The EX2000 uses the board for a different purpose than the drive does. The DCFB power supply board receives thirty-eight (38) and 115 VAC (24 VDC) input power from the control power transformer (CPT) and provides control level power to the drive and 115 VAC power to the enclosure fans. Features The DCFB board includes the following circuits. 

 Control level power supplies (+5, +/- 15 and +/- 24 VDC) Motor field power circuits (Except the SCR Module) Driver circuits for the motor field SCR gate pulse generators. Circuits to monitor numerous AC line & DC motor signals including Armature current and voltages Motor field current AC line current AC line Voltage magnitude and phase sequence. Characteristics DCFB boards include twelve configurable jumpers ( thirteen (13) on REV BKC and later boards) and seven DIP switches for the selection of customer options; most jumpers and DIP Switch selections are factory set. The +24 V dc supply is used by the DCFB board to produce a +5 V dc, 4 A output as well. When the +5 V dc supply is regulated, the /PSEN signal on 2PL enters a TTL low state. 

If the +5 V dc supply is not regulated, the signal enters a high state. When set to high, /PSEN causes the Drive Control Card's (SDCC/LDCC) microprocessor to reset. The armature current feedback circuits are powered by isolated +5 and 15 V dc supplies from the DCFB board. Fuse numbers FU2 and FU3 guard the power supply outputs against short circuits (7 A, 2AG). For these fuses, light-emitting diodes (LEDs) CR51 and CR55 offer blown fuse indications. Fuse FU1 (1/2 A, 2AG) is used to protect the 115 V ac output. Blowing fuses are indicated for FU1 by the neon light LT1. Voltage and Current Feedback VCO Voltage-controlled oscillator (VCO) circuits on the DCFB board transform input voltages into frequency signals. The nominal output frequency of each VCO is 250 kHz. Depending on the input voltage, the output frequency ranges from 0 to 500 kHz. 

Through connection 1PL, VCO outputs are transmitted to the SDCC/LDCC board to provide the following feedback: SCR bridge ac input voltage Output bridge voltage Motor voltage (NA) Millivolt signals from field shunts Millivolt signals from armature shunts Through connector 1PL, pin 13, the output bridge VCO circuit communicates feedback to the SDCC/LDCC board (1PL- 13). Scaling the voltage provided to the circuit is accomplished using DIP switch SW4. Testpoint TP37 on the SDCC/LDCC board receives a diagnostic signal through 1PL-37 from a frequency-to-voltage reconstruction circuit. An ac-coupled oscilloscope can be used to see the diagnostic bridge voltage signal. Through 1PL-39, the second VCO communicates motor voltage feedback to the SDCC/LDCC board. Scaling the voltage provided to the circuit is accomplished using DIP switch.

Hardware Tips and Specifications

This DS200DCFBG1B printed circuit board or PCB for short comes with its own series of hardware component inclusions and specifications that introduce its intended Mark V Series functionality. Voltages rated between 38 and 115 VAC can be directly supplied to the board via the control power transformer. Frequencies for the board are dependent upon the input voltage, but can range from 0 to 500 kHz.The board features a number of circuits that work to power the board and the installed drive. DS200DCFBG1B is comprised of motor field power, driver, AC/DC monitoring, and control level supply circuits. 

The twelve jumpers and seven DIP switches found on the board provide users with configurable system options; fuse switch diagnostics are presented using the two LED and one neon indicator lights found on the board. Any jumper present on the base circuit board of this DS200DCFBG1B product would be accompanied by the JP factory-printed nomenclature label, while with the DIP switches, it is the SW label. Three protective fuses prevent any interruptions in power supplies. DS200DCFBG1B Voltages can be monitored using the five test points integrated on the board. Similarly to this DS200DCFBG1B device's fuses, this DS200DCFBG1B product makes use of a specific series of connectors for interfacing opportunities with other Mark V Series products. 

This DS200DCFBG1B Power Supply Board utilizes eighteen total plug-style connectors and nine additional stab-style connectors, with various functions as listed in the DS200DCFBG1B Datasheet supplied above once again. The purposes of this DS200DCFBG1B Board's three included LED indicators are explained in detail in the original DS200DCFBG1B instructional manual attached above, and each LED indicator is accompanied by its own factory-printed nomenclature label. The LED diagnostic indicators included in the DS200DCFBG1B PCB's assembly include:

The CR51 FU2 dc regulator status LED indicator

The CR55 FU3 dc regulator status LED indicator

The LT1 FU1 ac line status LED indicator


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide