Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200PTBAG1B Termination Board Assembly
    ❤ Add to collection
  • GE DS200PTBAG1B Termination Board Assembly

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200PTBAG1B Termination Board Assembly

    • ¥23650.00
      ¥34670.00
      ¥23650.00
      ¥23650.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.400KG
    • Quantity:
    • (Inventory: 33)
Description

GE DS200PTBAG1B Termination Board Assembly


GE DS200PTBAG1B Termination Board Assembly

Part Number DS200PTBAG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200PTBAG1B is a Protection Termination Board manufactured by General Electric as part of the Mark V LM Series used in gas turbine control systems. The P1 core's signals are terminated by the Protection Termination Module (PTBA), which is located in the core. In P1, input signals for high and low pressure shaft speeds, flame detection, generator and bus voltages, and generator currents land on the PTBA terminal board and are connected to the TCEB board. 

The R1 core is also connected to the speed signals. DS200PTBAG1B Features The PTBA terminal board reads external trip input signals, generator and bus signals, and generator breaker close signals before writing them directly to the Turbine Trip (TCTG) board in the P1 core. The PTBA terminal board is used to write trip output signals and generator breaker close signals from the TCTG board to the unit. Using a hardware jumper on the PTBA board, the TCEB board's audio alarm (horn) is powered. It has 2 3-pin connectors, 1 LED on the board's side, and 8 jumpers. Two 50-pin connectors and one block of ten LEDs are also included. The LED on the board's side has the ID CR9. When illuminated, it is green in color and indicates that the board is getting electricity. 

The LED flashes to show that the board is processing information. A board that is not receiving power or not responding to voltage will not have an LED that is lighted. When the board is mounted in the rack cabinet between other boards, the LED is visible. From the window in the rack cabinet, you can see the LED. DS200PTBAG1B Applications For Primary Overspeed Defense The turbine speed sensor is usually connected to a pulse rate input on the PTBA terminal board in P1 core location 6. HP and LP shafts are landed on the PTBA terminal board in the P1 core and written to the X and Y boards in Emergency Overspeed Protection. Flame Detection Circuits TCEA UV flame detector signals are fed into the PTBA board via the P1 core. 

These signals are read from the PTBA terminal board to the TCEB board via the JVA and JU connectors and written to the TCEA board via the JK (JKX/Y/Z) connectors. DS200PTBAG1B Connectors JJR - Writes the high and low pressure shaft speed signals to the TCQE board in the R1 core. JM - In the P1 core, reads and writes the generator breaker signals (52GL) as well as the emergency trip outputs to and from the TCTG board. JN - In the P1 core, reads and writes the generator breaker signals (G125P), writes the enable signal to the horn, and reads external trip signals to/from the TCTG board. JU - Sends emergency overspeed, flame detect, and audible alarm (horn) enable signals to the TCEB board in the P1 core. JV - In the P1 core, writes the generator and bus voltage signals, as well as the current signals (PT and CT), to the TCEB board. 

JVA - Transports the 335 V dc from the TCEB board in the P1 core to the flame detection devices. JJS/T - Not commonly used. Hardware Configuration J1 Enable the audible alarm (horn). Remove to silence.DS200PTBAG1B (GE Termination Board) features two terminal blocks, with 72 signal wires each, terminal posts for 6 signal wires, and contains three 10-pin connectors. JJR, JJT and JJS are the ID?s for the 10-pin connectors.?nnDS200PTBAG1B (LCI) is designed to process 7 different termination signals. DS200PTBAG1B (LCI) has over speed magnetic pickups, DS200PTBAG1B has flame detectors, DS200PTBAG1B has bus volts, DS200PTBAG1B has generator volts and current, DS200PTBAG1B has synchronizing, DS200PTBAG1B has protective inputs, and DS200PTBAG1B has alarm horn enable and disable hardware jumper location as termination signals.nnThe next steps should only be done if the power is removed from the drive ?

 be sure to have a narrow flat blade screwdriver to remove a signal wire from a terminal on a terminal block.nnAfter the power is removed, to detect the presence of power in the drive, use a tester. The components in the drive, like capacitors, hold power during normal drive operations. After waiting 30 seconds, you will notice the power in the components exit the drive. 

To avoid shock, before testing any components, use a tester.?nnUsing the terminal block ID and terminal numerical ID, locate the signal wire you want to remove. With a narrow screwdriver, loosen the terminal retention screw and pull the wire from the terminal. Be sure to mark the terminal ID the signal wire is connected to! In order to connect the signal wire, insert it into the terminal and tighten the terminal retention screw.?nnDS200PTBAG1B has bus volts, DS200PTBAG1B also has generator volts and current.?nnThe termination board, DS200PTBAG1B (LCI), is for the independent protective module core.

Our Main Brands

· - ABB Advant-800xAAdvant OCSBailey Infi 90 and Net 90H&B Freelance 2000DSQC RobotsIGCT / IGBT

· - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax

· - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,

· - Bently Nevada 3300 System, 3500 System

· - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)

· - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC

· - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice