Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200SHVMG1A High Voltage M-Frame Interface Board
    ❤ Add to collection
  • GE DS200SHVMG1A High Voltage M-Frame Interface Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200SHVMG1A High Voltage M-Frame Interface Board

    • ¥22000.00
      ¥34670.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

GE DS200SHVMG1A High Voltage M-Frame Interface Board


GE DS200SHVMG1A High Voltage M-Frame Interface Board

Part Number DS200SHVMG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200SHVMG1A is an SCR High Voltage M-Frame Interface Board manufactured by General Electric under EX2000. The SCR High Voltage M-Frame Interface Board (SHVM) interfaces signals from the SCR bridge of an M-frame drive to the DCFB or SDCI Power Supply Board and PCCA Power Connect Card. Functional Description The SHVM board performs the following functions. Converts shunt signals (-500 mV to + 500 mV) into differential frequency outputs (0 - 500 kHz) that are sent to the DCFB or SDCI board. Incorporates hardware jumper selectable 10:1 current transformers to provide additional current attenuation capability. Provides attenuation of ac line, motor armature, and SCR bridge voltages The SHVM board includes configurable jumpers, wiring plug connectors, and stab connectors parts of the board. 

 DC Bridge Shunt Isolator Circuit Shunt signals from the bridge are converted by the dc positive (+) and dc negative () floating shunt isolator voltage controlled oscillator (VCO) circuits. The circuits are fed to the DCFB board and range from 500 mV to +500 mV (0 to 500 kHz). The input circuits of the isolators float to the bridge potentials of the dc+ and dc voltages. DCAC Current Transformers If required, the SHVM board provides 10:1 current transformer (CT) attenuation for alternating current line currents (phase A and phase C). This attenuation is switchable. Because the CT burden resistors on the SDCI and DCFB Power Supply Boards are not rated to handle more than 144 mA main line ACCT secondary current (rated dc current/ACCT ratio), attenuation is required above 144 mA. When the main line ACCT secondary current is less than 144 mA, attenuation should be turned off. 

 Application Data The SHVM board is a high voltage interface board with floating board hardware at feedback voltage potential. Even when the control power is turned off, a high voltage could be applied to the board. Before making any hardware changes or changing the board, ensure that all high voltage input is also deenergized. Board Hardware The SHVM board has configurable jumpers, wiring plug connectors, and stab connectors (but no LEDs, fuses, testpoints, or switches). Configurable Jumpers The SHVM board has configurable jumpers, wiring plug connectors, and stab connectors (but no LEDs, fuses, testpoints, or switches). Board Connectors The SHVM board communicates with the drive's other boards and devices via eight plug connectors (designated PL) and eighteen stab connectors.

The General Electric DS200SHVMG1A is a high voltage M-frame interface board. This unit is a member of the Mark V series of optional and replacement boards. When installed, this card provides an interface medium from the M-frame drive’s SCR bridge to the power supply board (DCFB or SDCI) as well as powerconnect cards (PCCA). A number of GE brand exciters and drives can have this board installed in its cabinet, although this DS200SHVMG1A PCB has specific applications in the control and management systems of wind, steam, and gas turbine automated drive assemblies. The Mark V Series that this DS200SHVMG1A SCR High-Voltage M-Frame Interface Board belongs to is a General Electric legacy series as its production has been discontinued in the years following its initial release. While this DS200SHVMG1A product offering's greater Mark V Turbine Control System Series is classifiable as a General Electric legacy series, it is also identifiable as one of the final General Electric product series to feature their patented Speedtronic control system technology. This DS200SHVMG1A SCR High-Voltage M-frame Interface Board is not the originally-manufactured device of its functionality to feature within the Mark V Series; that would be the DS200SHVMG1 parent printed circuit board missing this DS200SHVMG1A Board's A-rated functional product revision.

Hardware Tips and Specifications

When installed, DS200SHVMG1A provides an array of functions to the drive, which is achieved through its inclusion of a specific set of functionality-introducing hardware components and component specifications. Shunt signals between -500 and 500 mV are converted into differential frequency outputs between 0 and 500 kHz. These signals are then sent to either the DCFB or SDCI boards or the PCCA card. Using DC positive and negative floating shunts, the VCO (voltage controlled oscillator) circuits act as the conversion points for the voltages. This card also offers the AC line currents a 10:1 current transformer attenuation. Attenuation is user-selectable using the 17 onboard configurable jumpers. If the AC line voltage ranges from 240 to 600 V, bypass the attenuators. 

Should voltages range between 601 to 1000 V, they should be included. This DS200SHVMG1A printed circuit board features many more general, Mark V Series-standardized hardware components and component specifications in its assembly beyond just its functional component inclusions. For starters, the internal assembly of this DS200SHVMG1A printed circuit board makes use of a standard number of voltage-limiting and suppressing hardware components, such as capacitors, diodes, and rectifiers. Additional voltage protection for this static-sensitive DS200SHVMG1A printed circuit board exists in the form of its normal style of PCB protective coating and the insulated rings that have been carefully installed over this DS200SHVMG1A product's factory-drilled installation holes.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide