GE DS3800DVRC1A Regulator Circuit Board
GE DS3800DVRC1A Regulator Circuit Board
Part Number DS3800DVRC1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockThe DS3800DVRC1A is a GE regulator circuit board under the Mark IV series. It is a part of General Electric's Speedtronic series of products. While Mark IV components are no longer available from the OEM, many of these boards are still available from WOC, where we stock a large number of Speedtronic components. DS3800DVRC1A Features Three potentiometers, sometimes known as variable resistors, are included in the board.
Each variable resistor has a large black knob that is easy to grasp. The numerals zero to one hundred are plainly marked on each knob. With a single turn, you can acquire the current flow you need with a ten-degree increase from zero to one hundred. The knobs are additionally marked with little arrows for easy identification. The board relies on the five EEPROM devices on the board once the current flow has been regulated. The programming for the board's operation are stored in these EEPROMs. These devices, on the other hand, are not reprogrammable.
If extra programming is required, a second EEPROM can be placed in the "SPARE" area of the board. his part already has a current point around it, making it simple to add an EEPROM. Resistors are the components of the circuit board that make it a regulator. On this circuit board, there are two types of resistors. The first sort of resistor is modest in size but has a large number of them. This particular board has roughly seventy-six people on it. These tiny resistors are colored in a variety of ways. Each resistor's color corresponds to a code that tells the operator how many ohms it can withstand.
The "power resistor" is the second type of resistor. These power resistors come in a variety of sizes and are designed to manage high-power energy that may flow through the board during an energy spike. Mark IV Features The Mark IV control system was General Electric's first TMR (triple modular redundant) control system for gas and steam turbines in their popular Speedtronic series. The Operator Interface module in the Mark IV Speedtronic system is used to communicate with the turbine system. This module interface features input membrane switches as well as an emergency stop pushbutton. The Speedtronic system includes a panel-mounted printer for automatic logging and printing of specific parameters. Alarm Lockout, Alarm Logging, and various diagnostics are all available on the Mark IV. Administrative lists that allow for time/date data, scale sets, security codes, control identity selection, and PROM ids are also displayed as options.
The IO module has the following main functions
Input Function
The IO module can receive input signals sent by external devices and convert them into digital or analogue signals for use by the computer system or control system. These input signals can come from a variety of sensors, such as temperature sensors, pressure sensors, photosensitive sensors and so on. By receiving and parsing these input signals, the system can monitor and control the external environment in real time.
Output Functions
The IO module is capable of converting the output signals generated by a computer system or control system into the form required by an external device. These output signals are typically used to control actuators such as motors, valves, lights, etc. By sending appropriate output signals to external devices, the system enables control and operation of the external environment.
Data Acquisition and Processing
The IO module is capable of acquiring data from external devices and transferring it to a computer system or control system for further processing. This enables the system to acquire environmental data, status information and user inputs in real time and make appropriate decisions or perform specific tasks based on these data.
Communication Interfaces
IO modules are usually equipped with different types of communication interfaces, such as serial interfaces (RS232, RS485), Ethernet interfaces, CAN bus interfaces, and so on. These interfaces enable IO modules to exchange data and communicate efficiently with computer systems or other external devices.
Our Main Brands
· - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
· - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
· - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
· - Bently Nevada 3300 System, 3500 System
· - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
· - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
· - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
email:1583694102@qq.com