Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • DS3820MSAB1A1A | General Electric Printed Circuit Board
    ❤ Add to collection
  • DS3820MSAB1A1A | General Electric Printed Circuit Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    DS3820MSAB1A1A | General Electric Printed Circuit Board
    • ¥3455.00
      ¥9898.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 3)
Description
DS3820MSAB1A1A | General Electric Printed Circuit Board

DS3820MSAB1A1A | General Electric Printed Circuit Board

Product Description P/N: IS420UCSCH1B DESCRIPTION / SPECIFICATIONS Description The IS420UCSCH1B Quad-Core Controller, an iteration of the UCSC controller series by General Electric, features a quad-core design operating at 1.2 GHz AMD G-Series. Specifically tailored for implementation within the Mark VIe Series, this controller serves as the primary controller outlined in the GEH-6855 Volume II manual, distinguished by its real-time hypervisor functionality and QNX Neutrino multi-task capable operating system. Employing QNX, renowned for its reliability in high-speed industrial environments, the controller also integrates Embedded Field Agent (EMA) technology, facilitating the deployment of Predix cloud-based and web applications over stable connections. This synergy ensures the delivery of real-time data to connected controllers. 

 Unlike other controllers in the Mark VIe Series that rely on backplane for input-output functions, the IS420UCSCH1B controller operates independently, devoid of any I/O applications. Its software and hardware architecture ensures seamless operation even during controller shutdowns for maintenance or repair, safeguarding against data loss. 

 Technical Specifications Part Number IS420UCSCH1B Product Family Mark VIeS Functional Safety System Product Name Mark VIe Gateway Controller Manufacturer (OEM) GE Power Platform Configuration Supported Features EFA, Embedded EtherCAT, and Embedded PPNG Altitude for Normal Operation 0-1000 m at 101.3 to 89.9 kPa Memory Type 2 GB DDR3-1066 SDRAM, with error correcting code (ECC) NVSRAM 3067 Nonvolatile Program Variables, 64 Totalizers, and 338 Forces Storage Temperature -40 to 85C (-40 to 185 F) Dimensions with Mounting H 8.03 in x D 5.99 in x W 2.17 in HMI ControlST V07.00.00C or Later Redundancy Configurations Simplex, Dual Number of Ethernet Ports 6, 5 on Front Panel, and 1 on Bottom for Predix Connectivity Information 

About IS420UCSCH1B The GE Power IS420UCSCH1B is a part of the Mark VIeS Functional Safety System, serving as the Mark VIe Gateway Controller. This advanced controller is engineered to provide reliable and efficient control capabilities within industrial safety systems, ensuring both high performance and robust safety measures. Designed to support a range of platform configurations, the IS420UCSCH1B integrates key features such as EFA (Ethernet for Automation), embedded EtherCAT, and embedded PPNG (Power and Performance Networking Gateway). 

These features facilitate seamless communication and integration within industrial networks, enhancing the overall functionality and interoperability of the system. The controller operates effectively at altitudes ranging from 0 to 1000 meters, with pressure conditions between 101.3 to 89.9 kPa, ensuring reliable performance in various environmental conditions. This versatility makes it suitable for a wide range of industrial applications, from standard manufacturing environments to more challenging operational settings. Equipped with 2 GB of DDR3-1066 SDRAM memory featuring error correcting code (ECC), the IS420UCSCH1B ensures high-speed data processing and reliable operation. 

The ECC functionality helps in detecting and correcting data corruption, which is crucial for maintaining system integrity and preventing data loss or errors. The controller also includes NVSRAM with a capacity to handle 3067 nonvolatile program variables, 64 totalizers, and 338 forces. This substantial memory allocation ensures that critical data and control variables are retained even during power interruptions, enhancing system reliability and reducing downtime. The IS420UCSCH1B is designed to operate in a wide storage temperature range of -40 to 85掳C (-40 to 185掳F), underscoring its robustness and suitability for harsh industrial environments. 

Its compact dimensions, with a height of 8.03 inches, a depth of 5.99 inches, and a width of 2.17 inches, allow for easy installation and integration into existing systems. For human-machine interface (HMI) operations, the controller is compatible with ControlST V07.00.00C or later, providing a user-friendly interface for system configuration, monitoring, and control. This compatibility ensures that operators can efficiently manage and interact with the system, enhancing operational efficiency and safety. 

 The IS420UCSCH1B supports both simplex and dual redundancy configurations, offering flexibility in designing systems for varying levels of fault tolerance and reliability. This capability is particularly important in safety-critical applications where system availability and reliability are paramount. With six Ethernet ports, including five on the front panel and one on the bottom for Predix connectivity, the controller provides extensive networking capabilities. These ports facilitate robust and flexible network connections, enabling seamless communication with other system components and external networks. 

 In summary, the GE Power IS420UCSCH1B Mark VIe Gateway Controller is a high-performance, reliable component of the Mark VIeS Functional Safety System. Its advanced features, robust design, extensive memory, and flexible networking capabilities make it an ideal choice for ensuring efficient and safe operation in a wide range of industrial applications. Its compatibility with ControlST HMI software and support for various redundancy configurations further enhance its utility and reliability, making it a critical component for modern industrial safety systems. 

 Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide